Evaluation of Lead Exposure by Hand Wipes: A Review of the Effectiveness of Personal Hygiene on Industrial Sites

K. Guth, M. Bourgeois, G. Johnson, R. Harbison
{"title":"Evaluation of Lead Exposure by Hand Wipes: A Review of the Effectiveness of Personal Hygiene on Industrial Sites","authors":"K. Guth, M. Bourgeois, G. Johnson, R. Harbison","doi":"10.4236/odem.2019.74011","DOIUrl":null,"url":null,"abstract":"To evaluate the effectiveness of personal hygiene (handwashing) amongst workers at industrial sites to remove lead from their hands, a retrospective analysis of hand wipe samples was conducted using data collected by two contractors from two bridge painting projects for total lead using method ASTM E-1979-17/EPA SW846 7000B. Exposures resulted from the removal of lead-based paint from the structure and trace elements of lead found in the abrasive blast media. In total, six work tasks were evaluated and sixty unique hand wipe samples were evaluated. Thirty samples were collected during the worker’s lunch break, after they had reportedly washed their hands with a further 30 collected at the end of the workday following the same protocol. To be included in this evaluation, the contractors were required to follow NIOSH Method 9105 (Lead in Dust Wipes-Dermal Surfaces) with subsequent analysis of samples for total lead by an American Industrial Hygiene Association (AIHA) accredited laboratory. All 60 samples contained detectable lead. The lead exposures ranged from 19.5 μg to 3420 μg. The geometric mean for the samples collected was 337 μg. These results indicate that current personal hygiene practices at the evaluated sites are not effective at removing lead from worker’s hands during and after the workday. They also suggest that the residual lead measured on the workers’ hands, at the end of the shift, is likely contributing to the elevated blood lead levels in this population.","PeriodicalId":71955,"journal":{"name":"职业病与环境医学(英文)","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"职业病与环境医学(英文)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4236/odem.2019.74011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

To evaluate the effectiveness of personal hygiene (handwashing) amongst workers at industrial sites to remove lead from their hands, a retrospective analysis of hand wipe samples was conducted using data collected by two contractors from two bridge painting projects for total lead using method ASTM E-1979-17/EPA SW846 7000B. Exposures resulted from the removal of lead-based paint from the structure and trace elements of lead found in the abrasive blast media. In total, six work tasks were evaluated and sixty unique hand wipe samples were evaluated. Thirty samples were collected during the worker’s lunch break, after they had reportedly washed their hands with a further 30 collected at the end of the workday following the same protocol. To be included in this evaluation, the contractors were required to follow NIOSH Method 9105 (Lead in Dust Wipes-Dermal Surfaces) with subsequent analysis of samples for total lead by an American Industrial Hygiene Association (AIHA) accredited laboratory. All 60 samples contained detectable lead. The lead exposures ranged from 19.5 μg to 3420 μg. The geometric mean for the samples collected was 337 μg. These results indicate that current personal hygiene practices at the evaluated sites are not effective at removing lead from worker’s hands during and after the workday. They also suggest that the residual lead measured on the workers’ hands, at the end of the shift, is likely contributing to the elevated blood lead levels in this population.
用手巾评估铅暴露:工业场所个人卫生效果的评价
为了评估工业现场工人的个人卫生(洗手)去除手上铅的有效性,使用两名承包商从两个桥梁涂装项目收集的数据,使用ASTM E-1979-17/EPA SW846 7000B方法对擦手样本进行了回顾性分析。暴露是由于从结构中去除含铅涂料和在喷砂介质中发现的微量铅元素造成的。总共评估了6项工作任务,并评估了60个独特的擦手样本。据报道,在这名工人洗手后,在午休期间采集了30份样本,在工作日结束时按照同样的方案采集了另外30份。为了纳入本评估,承包商必须遵循NIOSH方法9105(灰尘擦拭皮肤表面中的铅),随后由美国工业卫生协会(AIHA)认可的实验室对样本进行总铅分析。所有60个样品都含有可检测的铅。铅暴露量范围为19.5μg至3420μg。所采集样品的几何平均值为337μg。这些结果表明,在工作日期间和工作日后,评估地点目前的个人卫生习惯无法有效去除工人手上的铅。他们还认为,在轮班结束时,工人手上测量到的残余铅可能是导致这一人群血铅水平升高的原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
36
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书