Influence of process parameters in removing wastewater impurities via progressive freeze crystallization

Q3 Materials Science
A. A. Mazzam, H. A. Hamizlan, Ikhmal Zariq Al Imran Jamal Ikhsan, M. Bakar, Farah Hanim Ab Hamid
{"title":"Influence of process parameters in removing wastewater impurities via progressive freeze crystallization","authors":"A. A. Mazzam, H. A. Hamizlan, Ikhmal Zariq Al Imran Jamal Ikhsan, M. Bakar, Farah Hanim Ab Hamid","doi":"10.5604/01.3001.0053.4741","DOIUrl":null,"url":null,"abstract":"The research aims to investigate the effect of the process parameter of progressive freeze concentration to eliminate tricholorophenol in wastewater.A stainless steel crystallizer was used throughout the experiment. Simulated wastewater containing trichlorophenol (TCP) was used as a sample solution, and ethylene glycol was utilized as a coolant to induce the heat transfer at a very low temperature. Progressive freeze crystallization (PFC) is an approach to purify water by implementing the fundamental concept of difference freezing point. In short, the PFC system produces ice-crystal layer by layer on a cooled surface until it forms a large and single-crystal block, leaving the impurities in the mother liquor.It is established that operating time and initial concentration influence the PFC performance. The findings show that the intermediate operating time gave the highest removal of TCP in wastewater. Meanwhile, for the effect of initial concentration, it was discovered that the lowest initial concentration resulted in the best TCP reduction with high purity of the water was obtained.The results can be complemented by studies of the effect of coolant temperature and solution movement. These two parameters are believed to potentially improve the PFC performance.The findings can be implemented to select the optimal operating condition to treat the wastewater, especially in the industrial area with hazardous TCP.The obtained results testify to the predominant influence of operating time and initial concentration on the PFC performance in eliminating TCP in wastewater.","PeriodicalId":8297,"journal":{"name":"Archives of materials science and engineering","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of materials science and engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5604/01.3001.0053.4741","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Materials Science","Score":null,"Total":0}
引用次数: 0

Abstract

The research aims to investigate the effect of the process parameter of progressive freeze concentration to eliminate tricholorophenol in wastewater.A stainless steel crystallizer was used throughout the experiment. Simulated wastewater containing trichlorophenol (TCP) was used as a sample solution, and ethylene glycol was utilized as a coolant to induce the heat transfer at a very low temperature. Progressive freeze crystallization (PFC) is an approach to purify water by implementing the fundamental concept of difference freezing point. In short, the PFC system produces ice-crystal layer by layer on a cooled surface until it forms a large and single-crystal block, leaving the impurities in the mother liquor.It is established that operating time and initial concentration influence the PFC performance. The findings show that the intermediate operating time gave the highest removal of TCP in wastewater. Meanwhile, for the effect of initial concentration, it was discovered that the lowest initial concentration resulted in the best TCP reduction with high purity of the water was obtained.The results can be complemented by studies of the effect of coolant temperature and solution movement. These two parameters are believed to potentially improve the PFC performance.The findings can be implemented to select the optimal operating condition to treat the wastewater, especially in the industrial area with hazardous TCP.The obtained results testify to the predominant influence of operating time and initial concentration on the PFC performance in eliminating TCP in wastewater.
工艺参数对渐进冷冻结晶法去除废水杂质的影响
研究了冷冻浓缩工艺参数对废水中三氯苯酚的去除效果。在整个实验中使用不锈钢结晶器。以含三氯苯酚(TCP)的模拟废水为样品溶液,乙二醇为冷却剂,在极低温度下诱导传热。渐进冷冻结晶(PFC)是一种通过实施差异冰点的基本概念来净化水的方法。简而言之,PFC系统在冷却的表面上逐层产生冰晶,直到形成一个大的单晶块,将杂质留在母液中。确定了操作时间和初始浓度对PFC性能的影响。结果表明,中间操作时间对废水中TCP的去除率最高。同时,对于初始浓度的影响,发现在获得高纯度水的情况下,最低的初始浓度导致最佳的TCP还原。研究冷却剂温度和溶液运动的影响可以补充这一结果。这两个参数被认为有可能改善PFC性能。研究结果可用于选择处理废水的最佳操作条件,特别是在含有有害TCP的工业区。研究结果证明,操作时间和初始浓度对PFC去除废水中TCP的性能有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Archives of materials science and engineering
Archives of materials science and engineering Materials Science-Materials Science (all)
CiteScore
2.90
自引率
0.00%
发文量
15
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信