Design methodology to determine the water quality monitoring strategy of a surface water treatment plant in the Netherlands

Q2 Engineering
P. Ross, K. van Schagen, L. Rietveld
{"title":"Design methodology to determine the water quality monitoring strategy of a surface water treatment plant in the Netherlands","authors":"P. Ross, K. van Schagen, L. Rietveld","doi":"10.5194/dwes-13-1-2020","DOIUrl":null,"url":null,"abstract":"Abstract. The primary goal of a drinking water company is to produce safe drinking water\nfulfilling the quality standards defined by national and international\nguidelines. To ensure the produced drinking water meets the quality\nstandards, the sampling of the drinking water is carried out on a regular\n(almost daily) basis. It is a dilemma that the operator wishes to have a\nhigh probability of detecting a bias while minimizing their measuring effort.\nIn this paper a seven-step design methodology is described which helps to\ndetermine a water quality (WQ) monitoring scheme. Besides using soft sensors as\nsurrogate sensors for parameters currently not available online, they can\npossibly provide a cost-effective alternative when used to determine\nmultiple parameters required through one single instrument.","PeriodicalId":53581,"journal":{"name":"Drinking Water Engineering and Science","volume":"13 1","pages":"1-13"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drinking Water Engineering and Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5194/dwes-13-1-2020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 1

Abstract

Abstract. The primary goal of a drinking water company is to produce safe drinking water fulfilling the quality standards defined by national and international guidelines. To ensure the produced drinking water meets the quality standards, the sampling of the drinking water is carried out on a regular (almost daily) basis. It is a dilemma that the operator wishes to have a high probability of detecting a bias while minimizing their measuring effort. In this paper a seven-step design methodology is described which helps to determine a water quality (WQ) monitoring scheme. Besides using soft sensors as surrogate sensors for parameters currently not available online, they can possibly provide a cost-effective alternative when used to determine multiple parameters required through one single instrument.
确定荷兰地表水处理厂水质监测策略的设计方法
摘要饮用水公司的主要目标是生产符合国家和国际准则规定的质量标准的安全饮用水。为了确保生产的饮用水符合质量标准,定期(几乎每天)对饮用水进行采样。操作员希望在最大限度地减少测量工作量的同时,有更高的概率检测到偏差,这是一个难题。本文介绍了一种有助于确定水质监测方案的七步设计方法。除了使用软传感器为当前无法在线获得的参数设置传感器外,当用于通过一个仪器确定所需的多个参数时,它们还可能提供一种具有成本效益的替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Drinking Water Engineering and Science
Drinking Water Engineering and Science Environmental Science-Water Science and Technology
CiteScore
3.90
自引率
0.00%
发文量
3
审稿时长
40 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信