Bispectral index monitoring in spinal anesthesia with sedation can prevent dexmedetomidine related bradycardia: a randomized clinical trial

IF 0.2 Q4 ANESTHESIOLOGY
Jiwook Kim, H. Kim, M. Yun, J. Lee, Joo-Duck Kim, D. Kang
{"title":"Bispectral index monitoring in spinal anesthesia with sedation can prevent dexmedetomidine related bradycardia: a randomized clinical trial","authors":"Jiwook Kim, H. Kim, M. Yun, J. Lee, Joo-Duck Kim, D. Kang","doi":"10.35975/apic.v26i1.1760","DOIUrl":null,"url":null,"abstract":"Background: An unintentional large dose of dexmedetomidine during sedation can lead to increased side effects such as bradycardia and hypotension. We investigated whether the frequency of bradycardia in patients undergoing surgery under spinal anesthesia and sedation with dexmedetomidine was effected if bispectral index (BIS) was used to monitor the sedation. \nMethodology: Fifty patients between 20 and 60 y of age, who underwent spinal anesthesia, were included in this study. The patients were divided into two groups (control and BIS groups). Patients in the control group were administered a loading dose of 1 μg/kg dexmedetomidine for the first 10 min without BIS monitoring, followed by a maintenance dose of 0.2 μg/kg/h. Patients in the BIS group received a loading dose of 1 μg/kg dexmedetomidine for the first 10 min. The maintenance dose in this group was administered at the discretion of the anesthesiologist to maintain the BIS score between 50 and 70. The baseline heart rate (HR), lowest HR, and the difference between baseline and the lowest HR were calculated. \nResults: The baseline HR was 74.4 ± 11.0 beats per minute (bpm) and 80.9 ± 16.0 bpm, in the control and BIS groups respectively (p = 0.098). The difference between the baseline and lowest HR in the control and BIS groups was 19.4 ± 7.6 bpm and 25.5 ± 8.8 bpm, respectively (p = 0.011). Low baseline HR was positively correlated with a reduced lowest HR. \nConclusions: The frequency of bradycardia during sedation with dexmedetomidine decreased with BIS monitoring. Patients with a low baseline HR were more likely to develop bradycardia during sedation with dexmedetomidine. Therefore, BIS monitoring may be helpful in patients with low baseline HR. \nKey words: Bispectral index monitor; Dexmedetomidine; heart rate; spinal anesthesia \nCitation: Kim J, Kim HY, Yun M, Lee J, Kim JD, Kang D. Bispectral index monitoring during sedation with dexmedetomidine in spinal anesthesia prevents bradycardia: a randomized clinical trial. Anaesth. pain intensive care 2021;26(1):14-19 ; \nDOI: 10.35975/apic.v26i1.1760","PeriodicalId":7735,"journal":{"name":"Anaesthesia, Pain & Intensive Care","volume":" ","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2022-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anaesthesia, Pain & Intensive Care","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35975/apic.v26i1.1760","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: An unintentional large dose of dexmedetomidine during sedation can lead to increased side effects such as bradycardia and hypotension. We investigated whether the frequency of bradycardia in patients undergoing surgery under spinal anesthesia and sedation with dexmedetomidine was effected if bispectral index (BIS) was used to monitor the sedation. Methodology: Fifty patients between 20 and 60 y of age, who underwent spinal anesthesia, were included in this study. The patients were divided into two groups (control and BIS groups). Patients in the control group were administered a loading dose of 1 μg/kg dexmedetomidine for the first 10 min without BIS monitoring, followed by a maintenance dose of 0.2 μg/kg/h. Patients in the BIS group received a loading dose of 1 μg/kg dexmedetomidine for the first 10 min. The maintenance dose in this group was administered at the discretion of the anesthesiologist to maintain the BIS score between 50 and 70. The baseline heart rate (HR), lowest HR, and the difference between baseline and the lowest HR were calculated. Results: The baseline HR was 74.4 ± 11.0 beats per minute (bpm) and 80.9 ± 16.0 bpm, in the control and BIS groups respectively (p = 0.098). The difference between the baseline and lowest HR in the control and BIS groups was 19.4 ± 7.6 bpm and 25.5 ± 8.8 bpm, respectively (p = 0.011). Low baseline HR was positively correlated with a reduced lowest HR. Conclusions: The frequency of bradycardia during sedation with dexmedetomidine decreased with BIS monitoring. Patients with a low baseline HR were more likely to develop bradycardia during sedation with dexmedetomidine. Therefore, BIS monitoring may be helpful in patients with low baseline HR. Key words: Bispectral index monitor; Dexmedetomidine; heart rate; spinal anesthesia Citation: Kim J, Kim HY, Yun M, Lee J, Kim JD, Kang D. Bispectral index monitoring during sedation with dexmedetomidine in spinal anesthesia prevents bradycardia: a randomized clinical trial. Anaesth. pain intensive care 2021;26(1):14-19 ; DOI: 10.35975/apic.v26i1.1760
双谱指数监测在腰麻镇静中预防右美托咪定相关心动过缓的随机临床试验
背景:镇静期间无意中大剂量右美托咪定会导致副作用增加,如心动过缓和低血压。我们研究了在脊柱麻醉和右美托咪定镇静下接受手术的患者,如果使用双频谱指数(BIS)监测镇静情况,是否会影响其心动过缓的频率。方法:本研究包括50名年龄在20至60岁之间的患者,他们接受了脊髓麻醉。将患者分为两组(对照组和BIS组)。对照组患者在没有BIS监测的情况下,在前10分钟给予1μg/kg的右美托咪定负荷剂量,随后给予0.2μg/kg/h的维持剂量。BIS组的患者在前10分钟接受1μg/kg右美托咪定的负荷剂量。该组的维持剂量由麻醉师自行决定,以将BIS评分维持在50至70之间。计算基线心率(HR)、最低HR以及基线与最低HR之间的差异。结果:对照组和BIS组的基线心率分别为74.4±11.0次/分和80.9±16.0次/分米(p=0.098)。对照组和BIS组的最低心率与基线心率之间的差异分别为19.4±7.6次/分和25.5±8.8次/分(p=0.011)。低基线心率与最低心率的降低呈正相关。结论:BIS监测可降低右美托咪定镇静期间的心动过缓频率。基线HR较低的患者在右美托咪定镇静期间更有可能出现心动过缓。因此,BIS监测可能有助于低基线HR患者。关键词:双谱指数监测;右美托咪定;心率;脊柱麻醉引文:Kim J,Kim HY,Yun M,Lee J,Kim JD,Kang D.双谱指数监测右美托咪定在脊柱麻醉中预防心动过缓:一项随机临床试验。Anaesth。疼痛重症监护2021;26(1):14-19;DOI:10.35975/apic.v26i.1760
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
56
审稿时长
4 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信