In-Situ Determination of Buildings’ Thermo- Physical Characteristics: Method Development, Experimentation, and Computation

A. Rasooli
{"title":"In-Situ Determination of Buildings’ Thermo- Physical Characteristics: Method Development, Experimentation, and Computation","authors":"A. Rasooli","doi":"10.7480/ABE.2020.07.4989","DOIUrl":null,"url":null,"abstract":"Ever since the introduction of energy conversion systems in the built environment, buildings have become responsible for a considerable share of global energy consumption. Many countries have therefore aimed to invest on buildings’ energy efficiency plans to reduce the depletion rate of the fossil resources and the CO2 emissions associated with them. In this context, accurate determination of building’s thermo-physical characteristics is a necessity in the processes which lead to execution of energy conservation strategies in existing buildings. These characteristics are the essential inputs for buildings’ thermal modelling, quality control, energy audits, and energy labelling, the results of which are determinant for energy renovation decisions and policies. In practice, the values of these parameters are not always available because the current determination methods are time-and-effort-expensive, and consequently rarely used. In accordance with the large deviations observed between the in-lab and in-situ thermal behaviour of building components, a special attention is laid on in-situ methods. This thesis aims at developing and testing different in-situ determination methods and approaches at different levels. Theories, simulations, and experiments, are combined for determination of a number of buildings’ most important thermo-physical characteristics. \nTransmission losses through the facades are known to be responsible for a significant portion of heat loss in buildings and consequently are investigated in all standard energy calculation methods. Thus, the major part of the thesis is dedicated to the thermal behaviour of exterior walls. The exact construction of existing walls is generally unknown. Consequently, the estimation of their thermal resistance, thermal conductivity, and volumetric heat capacity can be erroneous. Later, the attention is upscaled to the building level where rather than local characteristics, global characteristics are determined. \nAt the first stage, the walls’ in-situ determination of thermal resistance has been examined. Despite the advantages of the existing standard method, “ISO 9869 Average Method” for measuring this parameter, two problems have been pointed out: long duration and imprecision. Accordingly, this phase describes and demonstrates how the simplest modifications to this standard method can improve it in terms of solving these problems. Heat transfer simulations and experiments in a variety of wall typologies have been applied to show the effect of using an additional heat flux sensor, facing the first one, installed on the opposite side of the wall. Three estimations of thermal resistance based on either indoor or outdoor heat fluxes, and the average of the two values are then defined. It is shown that one of these values satisfies the convergence criteria earlier than the other two, leading to a quicker insitu determination of thermal resistance with a higher precision. \nTo further shorten the measurement period, in the second phase, a new transient in-situ method, Excitation Pulse Method, EPM, is developed and examined experimentally on three walls. The method is inspired by the theory of thermal response factors. In EPM, a triangular surface temperature excitation is applied at one side of the wall and the heat flux responses at both sides are measured and converted into the wall’s corresponding response factors which then leads to the wall’s thermal resistance. To validate, the results are compared to the ones obtained following the ISO 9869. The good agreement of the results confirms the possibility of measuring the Rc-value within a couple of hours. Applying this method, the overestimation of around 400% between the actual and estimated values (in practice, often based on the construction year) of thermal transmittance was resolved. Thus, EPM is believed to significantly improve the required time and accuracy in determination of the thermal behavior of walls with unknown constructions. Experimental and practical details regarding the design and construction of the method’s prototype as well as its application range are demonstrated subsequently. EPM has been patented in the Dutch patent office (Patent No. 2014467) and can be applied on in-lab and in-situ circumstances. \nFollowing the success in the proof of principle, in the third phase, detailed conditions for correct application of EPM in heavy and multi-layered walls are further studied. Heat transfer theories, simulations, and experiments are combined to evaluate the method’s performance for different types of walls. A specific attention is devoted to the relationship between the walls’ thermal response time and the response factors’ time interval, affecting the accuracy of Rc-value determination. Additionally, other hidden information in the response factors of the walls such as the possible construction are revealed. It is moreover demonstrated that in addition to the thermal resistance, the two main thermo-physical properties of a wall, the thermal conductivity and the volumetric heat capacity, as well as the wall’s thickness can be determined using inverse modelling of the Response Factors. The accuracy and precision of the method is tested in many different ways, fortifying the confidence for future application of this method. \nIn the last phase, the advancement of smart metering and monitoring systems in buildings are considered. Such smart technologies have led to utilization of the data from, for instance, home automation systems. This data acquisition is referred to as “on-board-monitoring” category of measurements, which removes the hassle, cost, and intrusion associated with locally-conducted experiments. The problem is then observed from a perspective wider than the component level. This time, the thermo-physical characteristics are studied for a whole building rather than just the walls. It is presumed that the current and future houses and their HVAC installations are by default, equipped with basic sensors, providing on-board monitored data. Therefore, the expected available data is measured and used as input parameters. A case study of an occupied apartment, in which air temperatures, humidity, and CO2 concentrations, gas consumption, and meteorological data have been measured for one year is investigated. Global characteristics such as the heat loss coefficient and thermal capacitance are estimated through inverse modelling of a 1st order circuit analogous to the thermal model of the building, and fed by the measurement data. In addition, using construction information, winter daily air change rates leading to ventilation and infiltration heat losses are estimated from the results of the inverse modelling. These results can be used to tailor the energy efficient use of the building. \nIn summary, the in-situ determination of walls’ thermal resistance is conducted by two methods in this thesis. The first one calls for longer measurement methods (minimum three days), but includes a straight-forward, well-known procedure. This method is highly suitable for high temperature gradients across the wall. The second method, EPM, requires more complicated instrumentation, but in return, in addition to rapid (couple of hours) determination of the Rc-value, it provides the walls’ response factors which are required for a dynamic thermal building simulation. In addition, using the results of this method, the thermal conductivity and volumetric heat capacity can be determined. EPM is most suitable for light-to-medium weighted walls and for homogeneous walls of known thickness. Stable heat flux profiles at the surfaces of the wall increase the accuracy of the method, especially when the temperature gradients across the wall are lower. Finally, as a less intrusive approach, the data from the HVAC installations’ existing sensors can be used. Global characteristics including the heat loss coefficient and the global capacitance can be then determined for a whole building, followed by ventilation and infiltration losses. Despite the low accuracy, this process is more suitable when the smart meter data is available and measurements at component level are not desired. \nBy introducing and testing new experimental and computational methods and approaches for reliable determination of buildings’ local and global thermo-physical characteristics, this thesis pays a significant contribution to the accuracy of the energy-related predictions and operations, especially within the built environment.","PeriodicalId":30436,"journal":{"name":"ABE Architecture and the Built Environment","volume":"1 1","pages":"1-228"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ABE Architecture and the Built Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7480/ABE.2020.07.4989","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Ever since the introduction of energy conversion systems in the built environment, buildings have become responsible for a considerable share of global energy consumption. Many countries have therefore aimed to invest on buildings’ energy efficiency plans to reduce the depletion rate of the fossil resources and the CO2 emissions associated with them. In this context, accurate determination of building’s thermo-physical characteristics is a necessity in the processes which lead to execution of energy conservation strategies in existing buildings. These characteristics are the essential inputs for buildings’ thermal modelling, quality control, energy audits, and energy labelling, the results of which are determinant for energy renovation decisions and policies. In practice, the values of these parameters are not always available because the current determination methods are time-and-effort-expensive, and consequently rarely used. In accordance with the large deviations observed between the in-lab and in-situ thermal behaviour of building components, a special attention is laid on in-situ methods. This thesis aims at developing and testing different in-situ determination methods and approaches at different levels. Theories, simulations, and experiments, are combined for determination of a number of buildings’ most important thermo-physical characteristics. Transmission losses through the facades are known to be responsible for a significant portion of heat loss in buildings and consequently are investigated in all standard energy calculation methods. Thus, the major part of the thesis is dedicated to the thermal behaviour of exterior walls. The exact construction of existing walls is generally unknown. Consequently, the estimation of their thermal resistance, thermal conductivity, and volumetric heat capacity can be erroneous. Later, the attention is upscaled to the building level where rather than local characteristics, global characteristics are determined. At the first stage, the walls’ in-situ determination of thermal resistance has been examined. Despite the advantages of the existing standard method, “ISO 9869 Average Method” for measuring this parameter, two problems have been pointed out: long duration and imprecision. Accordingly, this phase describes and demonstrates how the simplest modifications to this standard method can improve it in terms of solving these problems. Heat transfer simulations and experiments in a variety of wall typologies have been applied to show the effect of using an additional heat flux sensor, facing the first one, installed on the opposite side of the wall. Three estimations of thermal resistance based on either indoor or outdoor heat fluxes, and the average of the two values are then defined. It is shown that one of these values satisfies the convergence criteria earlier than the other two, leading to a quicker insitu determination of thermal resistance with a higher precision. To further shorten the measurement period, in the second phase, a new transient in-situ method, Excitation Pulse Method, EPM, is developed and examined experimentally on three walls. The method is inspired by the theory of thermal response factors. In EPM, a triangular surface temperature excitation is applied at one side of the wall and the heat flux responses at both sides are measured and converted into the wall’s corresponding response factors which then leads to the wall’s thermal resistance. To validate, the results are compared to the ones obtained following the ISO 9869. The good agreement of the results confirms the possibility of measuring the Rc-value within a couple of hours. Applying this method, the overestimation of around 400% between the actual and estimated values (in practice, often based on the construction year) of thermal transmittance was resolved. Thus, EPM is believed to significantly improve the required time and accuracy in determination of the thermal behavior of walls with unknown constructions. Experimental and practical details regarding the design and construction of the method’s prototype as well as its application range are demonstrated subsequently. EPM has been patented in the Dutch patent office (Patent No. 2014467) and can be applied on in-lab and in-situ circumstances. Following the success in the proof of principle, in the third phase, detailed conditions for correct application of EPM in heavy and multi-layered walls are further studied. Heat transfer theories, simulations, and experiments are combined to evaluate the method’s performance for different types of walls. A specific attention is devoted to the relationship between the walls’ thermal response time and the response factors’ time interval, affecting the accuracy of Rc-value determination. Additionally, other hidden information in the response factors of the walls such as the possible construction are revealed. It is moreover demonstrated that in addition to the thermal resistance, the two main thermo-physical properties of a wall, the thermal conductivity and the volumetric heat capacity, as well as the wall’s thickness can be determined using inverse modelling of the Response Factors. The accuracy and precision of the method is tested in many different ways, fortifying the confidence for future application of this method. In the last phase, the advancement of smart metering and monitoring systems in buildings are considered. Such smart technologies have led to utilization of the data from, for instance, home automation systems. This data acquisition is referred to as “on-board-monitoring” category of measurements, which removes the hassle, cost, and intrusion associated with locally-conducted experiments. The problem is then observed from a perspective wider than the component level. This time, the thermo-physical characteristics are studied for a whole building rather than just the walls. It is presumed that the current and future houses and their HVAC installations are by default, equipped with basic sensors, providing on-board monitored data. Therefore, the expected available data is measured and used as input parameters. A case study of an occupied apartment, in which air temperatures, humidity, and CO2 concentrations, gas consumption, and meteorological data have been measured for one year is investigated. Global characteristics such as the heat loss coefficient and thermal capacitance are estimated through inverse modelling of a 1st order circuit analogous to the thermal model of the building, and fed by the measurement data. In addition, using construction information, winter daily air change rates leading to ventilation and infiltration heat losses are estimated from the results of the inverse modelling. These results can be used to tailor the energy efficient use of the building. In summary, the in-situ determination of walls’ thermal resistance is conducted by two methods in this thesis. The first one calls for longer measurement methods (minimum three days), but includes a straight-forward, well-known procedure. This method is highly suitable for high temperature gradients across the wall. The second method, EPM, requires more complicated instrumentation, but in return, in addition to rapid (couple of hours) determination of the Rc-value, it provides the walls’ response factors which are required for a dynamic thermal building simulation. In addition, using the results of this method, the thermal conductivity and volumetric heat capacity can be determined. EPM is most suitable for light-to-medium weighted walls and for homogeneous walls of known thickness. Stable heat flux profiles at the surfaces of the wall increase the accuracy of the method, especially when the temperature gradients across the wall are lower. Finally, as a less intrusive approach, the data from the HVAC installations’ existing sensors can be used. Global characteristics including the heat loss coefficient and the global capacitance can be then determined for a whole building, followed by ventilation and infiltration losses. Despite the low accuracy, this process is more suitable when the smart meter data is available and measurements at component level are not desired. By introducing and testing new experimental and computational methods and approaches for reliable determination of buildings’ local and global thermo-physical characteristics, this thesis pays a significant contribution to the accuracy of the energy-related predictions and operations, especially within the built environment.
建筑物热物理特性的现场测定:方法开发、实验和计算
此外,还证明,除了热阻之外,壁的两个主要热物理特性,即热导率和体积热容,以及壁的厚度,都可以使用响应因子的反向建模来确定。该方法的准确性和精密度通过多种不同的方式进行了测试,增强了该方法未来应用的信心。在最后一个阶段,考虑了建筑物中智能计量和监控系统的发展。这种智能技术已经导致了对来自例如家庭自动化系统的数据的利用。这种数据采集被称为“车载监测”测量类别,它消除了与本地进行的实验相关的麻烦、成本和入侵。然后从比组件级别更宽的角度来观察问题。这一次,研究的是整个建筑的热物理特性,而不仅仅是墙壁。据推测,目前和未来的房屋及其暖通空调装置默认配备了基本传感器,提供车载监测数据。因此,测量预期的可用数据并将其用作输入参数。对一个有人居住的公寓的案例研究进行了调查,其中测量了一年的空气温度、湿度和二氧化碳浓度、气体消耗量和气象数据。通过类似于建筑物热模型的一阶电路的逆建模来估计热损失系数和热容量等全局特性,并由测量数据提供。此外,利用施工信息,根据反向建模的结果估计了导致通风和渗透热损失的冬季每日空气变化率。这些结果可用于调整建筑物的节能使用。综上所述,本文采用两种方法对墙体热阻进行了现场测定。第一个要求更长的测量方法(至少三天),但包括一个直接的、众所周知的程序。这种方法非常适合于跨越墙壁的高温梯度。第二种方法,EPM,需要更复杂的仪器,但作为回报,除了快速(几个小时)确定Rc值外,它还提供了动态热建筑模拟所需的墙壁响应系数。此外,利用该方法的结果,可以确定热导率和体积热容。EPM最适用于轻至中等重量的壁和已知厚度的均匀壁。壁表面的稳定热通量分布增加了该方法的准确性,尤其是当壁上的温度梯度较低时。最后,作为一种侵入性较小的方法,可以使用暖通空调装置现有传感器的数据。然后可以确定整个建筑的整体特征,包括热损失系数和整体电容,然后确定通风和渗透损失。尽管精度较低,但当智能仪表数据可用且不希望在组件级别进行测量时,该过程更适合。通过引入和测试新的实验和计算方法和方法来可靠地确定建筑物的局部和全局热物理特性,本文对能源相关预测和操作的准确性做出了重大贡献,尤其是在建筑环境中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书