Impacts of hydration and dehydration on microfiltration point-of-use filters: performance and cleaning impacts

IF 1.6 4区 环境科学与生态学 Q3 WATER RESOURCES
Andrea Ninabanda Ocampo, Brett E. Holden, O. Basu
{"title":"Impacts of hydration and dehydration on microfiltration point-of-use filters: performance and cleaning impacts","authors":"Andrea Ninabanda Ocampo, Brett E. Holden, O. Basu","doi":"10.2166/washdev.2023.249","DOIUrl":null,"url":null,"abstract":"\n This research examines the performance of two commercially available point-of-use (POU) microfiltration membrane filters (MF) under hydrated (wet) versus a multi-day dry period (dehydrated). Filter performance is monitored in terms of water quality and flowrate, as well as flowrate recovery following different cleaning regimes. The cleaning methods tested were backwashing with filtrate at room temperature, filtrate heated to 45 °C, filtrate at 45 °C with gentle shaking, and a vinegar solution (5% acetic acid). The selected cleaning methods reflect easily accessible cleaning methods with a goal to assess their impacts on flowrate recovery under both wet and dry conditions. After initial testing, hydrated MF flowrate varied between 197 ± 22 mL/min and backwashing with filtrate at room temperature was sufficient to maintain the membrane flowrate, while any of the other methods initially improved the system flowrate. In experiments where the filters were subject to a 5-day dry condition MF flowrates dropped to 65 ± 35 mL/min and filtrate at room temperature did not recover the flowrate sufficiently, however heated filtrate (45 °C) with/without gentle shaking was effective at recovering the MF for use. Water quality remained similar throughout the study, and 0 CFU/mL of E. coli were found in filtrate samples.","PeriodicalId":48893,"journal":{"name":"Journal of Water Sanitation and Hygiene for Development","volume":" ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2023-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Water Sanitation and Hygiene for Development","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.2166/washdev.2023.249","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"WATER RESOURCES","Score":null,"Total":0}
引用次数: 0

Abstract

This research examines the performance of two commercially available point-of-use (POU) microfiltration membrane filters (MF) under hydrated (wet) versus a multi-day dry period (dehydrated). Filter performance is monitored in terms of water quality and flowrate, as well as flowrate recovery following different cleaning regimes. The cleaning methods tested were backwashing with filtrate at room temperature, filtrate heated to 45 °C, filtrate at 45 °C with gentle shaking, and a vinegar solution (5% acetic acid). The selected cleaning methods reflect easily accessible cleaning methods with a goal to assess their impacts on flowrate recovery under both wet and dry conditions. After initial testing, hydrated MF flowrate varied between 197 ± 22 mL/min and backwashing with filtrate at room temperature was sufficient to maintain the membrane flowrate, while any of the other methods initially improved the system flowrate. In experiments where the filters were subject to a 5-day dry condition MF flowrates dropped to 65 ± 35 mL/min and filtrate at room temperature did not recover the flowrate sufficiently, however heated filtrate (45 °C) with/without gentle shaking was effective at recovering the MF for use. Water quality remained similar throughout the study, and 0 CFU/mL of E. coli were found in filtrate samples.
水合和脱水对微滤使用点过滤器的影响:性能和清洁影响
这项研究考察了两种市售使用点(POU)微滤膜过滤器(MF)在水合(潮湿)和多日干燥期(脱水)下的性能。根据水质和流量以及不同清洁制度下的流量回收率来监测过滤器性能。测试的清洁方法是在室温下用滤液进行反洗,将滤液加热至45°C,在45°C下轻轻摇动滤液,并用醋溶液(5%乙酸)进行反洗。所选的清洁方法反映了易于使用的清洁方法,目的是评估其在潮湿和干燥条件下对流量回收的影响。初始测试后,水合MF流量在197±22 mL/min之间变化,在室温下用滤液反洗足以维持膜流量,而任何其他方法最初都能提高系统流量。在过滤器处于5天干燥条件下的实验中,MF流速降至65±35 mL/min,室温下的滤液不能充分恢复流速,但加热滤液(45°C)和/或不轻轻摇动可有效恢复MF以供使用。在整个研究过程中,水质保持相似,在滤液样本中发现0 CFU/mL大肠杆菌。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.10
自引率
11.80%
发文量
58
审稿时长
16 weeks
期刊介绍: The Journal of Water, Sanitation and Hygiene for Development is a peer-reviewed journal devoted to the dissemination of high-quality information on the science, policy and practice of drinking-water supply, sanitation and hygiene at local, national and international levels.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信