{"title":"Fluid-retained denture","authors":"Amanpreet Kaur, Anupama Verma, Manmeet Kaur, Amit Sharma, Ramandeep Singh","doi":"10.4103/jdrr.jdrr_10_23","DOIUrl":null,"url":null,"abstract":"For uniform distribution of the masticatory stress, a complete denture should have enough hardness on the polished surface and pliability and softness on the intaglio surface of the denture. Conventional dentures have a major flaw in that they are firm on the tissue surface, resulting in an unequal force distribution. In cases of flabby ridges, unemployed ridges with high resorption, a conventional denture might worsen the situation. To address this, a variety of materials and methods are being tested to see if they may offer a cushioning effect to the tissues in contact with the denture. The following report describes a fluid-retained maxillary complete denture, which has a flexible tissue surface that allows the underlying anterior hyperplastic condition to have a uniform stress distribution, which can improve the patient's acceptance.","PeriodicalId":31325,"journal":{"name":"Journal of Dental Research and Review","volume":"10 1","pages":"36 - 40"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Research and Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jdrr.jdrr_10_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

For uniform distribution of the masticatory stress, a complete denture should have enough hardness on the polished surface and pliability and softness on the intaglio surface of the denture. Conventional dentures have a major flaw in that they are firm on the tissue surface, resulting in an unequal force distribution. In cases of flabby ridges, unemployed ridges with high resorption, a conventional denture might worsen the situation. To address this, a variety of materials and methods are being tested to see if they may offer a cushioning effect to the tissues in contact with the denture. The following report describes a fluid-retained maxillary complete denture, which has a flexible tissue surface that allows the underlying anterior hyperplastic condition to have a uniform stress distribution, which can improve the patient's acceptance.
液体保留义齿
为了使咀嚼应力均匀分布,全口义齿抛光表面应具有足够的硬度,凹版表面应具有柔软性。传统义齿的一个主要缺陷是它们在组织表面很牢固,导致力分布不均。在松弛的嵴、高吸收率的无工作嵴的情况下,常规义齿可能会使情况恶化。为了解决这个问题,正在测试各种材料和方法,看看它们是否可以为与义齿接触的组织提供缓冲作用。以下报告描述了一种液体保留的上颌全口义齿,该义齿具有灵活的组织表面,使潜在的前部增生状况具有均匀的应力分布,这可以提高患者的接受度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书