{"title":"POTENTIAL MEANS FOR MITIGATION OF MAGNETIC FIELD GENERATED BY UNDERGROUND POWER CABLES IN POLYETHYLENE PIPES MADE OF COMPOSITE MAGNETIC MATERIAL","authors":"I. Kucheriava","doi":"10.15407/techned2023.03.003","DOIUrl":null,"url":null,"abstract":"The magnetic field of the medium- and high-voltage underground power cable line, laid in composite polyethylene pipes having magnetic properties, with the use of special loose-fill/fill-up soil of different dimensions (bulk) is studied by computer modeling. The pipes and additional soils around and near the cables are made of a composite material with effective magnetic properties and can act as a magnetic shield that reduces the level of the field on the ground. The effi-ciency of field shielding depending on the height and width of the composite loose-fill/fill-up soil is analyzed. The exis-tence of the optimal not large (in height) fill-up soil for the best mitigation of the magnetic field on the ground directly above the cables and the influence of the width of the loose-fill/fill-up soils on the shielding efficiency are revealed. The characteristic features of the magnetic field distribution and the field level depending on the availability or non-availability of composite loose-fill soil are presented. The advantages of (trefoil) cable arrangement in one pipe with additional composite loose-fill and fill-up soil are shown. References 30, figures 5.","PeriodicalId":38557,"journal":{"name":"Technical Electrodynamics","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technical Electrodynamics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15407/techned2023.03.003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Energy","Score":null,"Total":0}
引用次数: 0
Abstract
The magnetic field of the medium- and high-voltage underground power cable line, laid in composite polyethylene pipes having magnetic properties, with the use of special loose-fill/fill-up soil of different dimensions (bulk) is studied by computer modeling. The pipes and additional soils around and near the cables are made of a composite material with effective magnetic properties and can act as a magnetic shield that reduces the level of the field on the ground. The effi-ciency of field shielding depending on the height and width of the composite loose-fill/fill-up soil is analyzed. The exis-tence of the optimal not large (in height) fill-up soil for the best mitigation of the magnetic field on the ground directly above the cables and the influence of the width of the loose-fill/fill-up soils on the shielding efficiency are revealed. The characteristic features of the magnetic field distribution and the field level depending on the availability or non-availability of composite loose-fill soil are presented. The advantages of (trefoil) cable arrangement in one pipe with additional composite loose-fill and fill-up soil are shown. References 30, figures 5.