Evaluating the Effectiveness of the Original Designs of Immediate-Prostheses after Multiple Tooth Extraction: Clinical Cases

A. V. Gus’kov, S. A. Mashutin, A. Oleinikov, M. K. Zainutdinov, E. A. Klimenko, L. Toropova
{"title":"Evaluating the Effectiveness of the Original Designs of Immediate-Prostheses after Multiple Tooth Extraction: Clinical Cases","authors":"A. V. Gus’kov, S. A. Mashutin, A. Oleinikov, M. K. Zainutdinov, E. A. Klimenko, L. Toropova","doi":"10.25207/1608-6228-2023-30-4-96-109","DOIUrl":null,"url":null,"abstract":"Background. Rehabilitation of patients with chronic periodontal diseases leading to multiple tooth loss can be carried out using the method of immediate prosthetics. However, the likelihood of atrophy of denture-supporting tissues under non-physiological load with removable dental prostheses imposes special requirements for their design features.Case description. Two patients seeking for dental surgical and prosthetic treatment for the diagnosis of chronic generalized periodontitis were treated in the dental clinic of Ryazan State Medical University named after academician I.P. Pavlov. Patient A. was mounted immediate prostheses made using additive technologies with the original design of the drug reservoir. Patient B. was mounted immediate prostheses with bases made of acrylic plastic, border ring of elastic polymer, and a drug reservoir made of polymethyl methacrylate. Patients underwent tooth extraction with immediate prosthetics. Patients were followed for 21 days. Criteria for the effectiveness of treatment included visual and palpatory control of extraction sites with a planimetric wound size analysis, assessment of microcirculation at the extraction site, control of the drug persistence in the reservoirs of prostheses.Conclusion. The observations at the stages of prosthodontic treatment revealed that immediate prostheses made with the help of 3D modeling and printing technologies resulted in a normal course of healing after tooth extraction with the normalization of microcirculatory parameters at the surgical wound sites. When using combined prosthetic structures, healing of postoperative wounds also proceeded favorably, however, congestion in the microcirculatory system was noted.","PeriodicalId":33483,"journal":{"name":"Kubanskii nauchnyi meditsinskii vestnik","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kubanskii nauchnyi meditsinskii vestnik","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25207/1608-6228-2023-30-4-96-109","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background. Rehabilitation of patients with chronic periodontal diseases leading to multiple tooth loss can be carried out using the method of immediate prosthetics. However, the likelihood of atrophy of denture-supporting tissues under non-physiological load with removable dental prostheses imposes special requirements for their design features.Case description. Two patients seeking for dental surgical and prosthetic treatment for the diagnosis of chronic generalized periodontitis were treated in the dental clinic of Ryazan State Medical University named after academician I.P. Pavlov. Patient A. was mounted immediate prostheses made using additive technologies with the original design of the drug reservoir. Patient B. was mounted immediate prostheses with bases made of acrylic plastic, border ring of elastic polymer, and a drug reservoir made of polymethyl methacrylate. Patients underwent tooth extraction with immediate prosthetics. Patients were followed for 21 days. Criteria for the effectiveness of treatment included visual and palpatory control of extraction sites with a planimetric wound size analysis, assessment of microcirculation at the extraction site, control of the drug persistence in the reservoirs of prostheses.Conclusion. The observations at the stages of prosthodontic treatment revealed that immediate prostheses made with the help of 3D modeling and printing technologies resulted in a normal course of healing after tooth extraction with the normalization of microcirculatory parameters at the surgical wound sites. When using combined prosthetic structures, healing of postoperative wounds also proceeded favorably, however, congestion in the microcirculatory system was noted.
多颗牙齿拔除后即刻修复体原始设计的疗效评价:临床病例
背景导致多颗牙齿脱落的慢性牙周病患者的康复可以使用即时修复的方法进行。然而,可移除义齿在非生理负荷下义齿支撑组织萎缩的可能性对其设计特征提出了特殊要求。案例描述。梁赞国立医科大学以巴甫洛夫院士的名字命名的牙科诊所治疗了两名寻求牙科手术和修复治疗以诊断慢性全身性牙周炎的患者。患者A.立即安装了使用添加剂技术制成的假体,并采用了药物贮存器的原始设计。患者B立即安装假肢,假肢底座由丙烯酸塑料制成,边缘环由弹性聚合物制成,储药器由聚甲基丙烯酸甲酯制成。患者接受了立即修复的拔牙手术。患者随访21天。治疗有效性的标准包括通过平面伤口大小分析对提取部位进行视觉和触诊控制,评估提取部位的微循环,控制假体储库中的药物持久性。结论在修复治疗阶段的观察表明,在3D建模和打印技术的帮助下制作的即时修复体在拔牙后恢复了正常的愈合过程,并使手术伤口部位的微循环参数正常化。当使用组合假体结构时,术后伤口的愈合也很顺利,但注意到微循环系统充血。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
37
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信