Normative ranges of tympanometric measurements in cats

Y. Sirin, Özlem Şengöz Şirin
{"title":"Normative ranges of tympanometric measurements in cats","authors":"Y. Sirin, Özlem Şengöz Şirin","doi":"10.24880/maeuvfd.813073","DOIUrl":null,"url":null,"abstract":"Middle ear diseases are common in cats. The aim of this study was to determine the normative tympanometric data of cats. Tympanometry, which provides objective data in the examination of the middle ear in humans, can be used as a supplementary examination, especially in cats with middle ear diseases where the external ear canal is normal. In this study, 30 healthy ears belonging to 15 cats which were classified as ASA-I (American Society of Anesthesiologyist) were determined and evaluated according to equivalent ear canal volume (Vea), static acoustic admittance [Ytm (compliance)], tympanometric peak pressure (TPP) and gradient values under general anesthesia. Tympanometric measurements obtained from right and left ears were 0.61 ± 0.12 ml and 0.60 ± 0.12 ml Vea, 0.31 ± 0.11 ml and 0.31 ± 0.11 ml Ytm, -11.2 ± 26.9 daPa and -14.9 ± 29.2 daPa TPP, 0.19 ± 0.11 ml and 0.24 ± 0.18 ml gradient respectively.Tympanometry as a supplementary examination is an easy to perform test in healthy cats with consistent results. It has the advantages of being completed in a short time, easy evaluation and providing information about middle ear without advanced imaging techniques. Results of this study represents the normative tympanometric measurements of cats which can be helpful distinguishing normal and abnormal conditions. Further studies needed to present exact values of standart tympanometric measurements and to introduce other variables like acustic refleks, wideband and multifrequency tympanometric results. 1Department of Surgery, Faculty of Veterinary Medicine, Burdur Mehmet Akif Ersoy University, Burdur/TURKEY MAE Vet Fak Derg, 5 (3): 131134, 2020 DOI: 10.24880/maeuvfd.813073 Bu makaleye atıfta bulunmak için/ To cite this article: YS ŞİRİN, Ö ŞENGÖZ-ŞİRİN. Normative ranges of tympanometric measurements in cats. MAE Vet Fak Derg. 2020; 5 (3) :131-134. INTRODUCTION Impedance audiometry has two main components: tympanometry and stapedius reflex measurement (1). Tympanometry is one of the most frequently performed and important components of the basic audiological evaluation. Objective middle ear assessment can best be performed by tympanometry (2). It measures how the middle-ear system responds to sound energy and changes in atmospheric pressure. It provides an objective, physiological measure of the acoustic admittance of the middle ear with the aid of air pressure in a sealed ear canal (3). The permeability and resistance of the middle ear system is defined with tympanometry via measuring the response to a sound stimulus using a microphone while pressure is changed along the external ear canal (4). The purpose of tympanometry is to asses audition on the basis of an objective description of the integrity and compliance of the eardrum, the mobility of the ossicular chain, the function of middle ear muscles and their attachments, and the size of the external ear canal (3). Data can be obtained from a tympanometer are estimated volume of air in front of the probe (equivalent ear canal volume, Vea), maximum compliance (Ytm), pressure at which the middle ear system has the greatest absorption of sound energy (TPP) and gradient of the tympanogram curve (5). Qualitative and quantitative approaches have been used in the interpretation of 226-Hz tympanograms (6). Tympanograms can most simply be classified as types A, B, and C depending on the curve shape compared to 0 as the pressure is changed (2). Further classification according to the shape of the curve is also used widely, type A as normal and type B, C, AD and AS as abnormal. Quantitative analysis of tympanograms is prefered, especially when evaluating infants and children, for whom different age-based normative values are needed (6). Definitions within modified Jerger classifications of tympanogram is described according to middle ear compliance (Ytm in ml) and middle ear pressure (TPP in daPa) as: type A (Ytm ≥0.2; TPP above –100), C1 (Ytm ≥0.2; TPP below or equal to –100 and above –200), C2 (Ytm ≥0.2; TPP below or equal to –100 and above –400) and B (Ytm <0.2; TPP below or equal to –400). Clinicians usually combine A and C1 as normal (7). The aim of this study was to evaluate the usefulness and consistency of the 226Hz tympanometer and its values in healthy cats. However, there are early tympanometry articles with cats, according to the authors knowledge these are the first published in vivo normal tympanometry values. MATERIAL and METHODS Cats brought to Mehmet Akif Ersoy University Animal Hospital for elective surgery without ear problems were included in the study. The study was approved by the Ethics Commission of Mehmet Akif Ersoy University. Fifteen mixed breed male (n: 7) and female (n: 8) cats at the age between 12-24 months included in the study. All cats were clinically Research Article","PeriodicalId":32481,"journal":{"name":"Mehmet Akif Ersoy Universitesi Veteriner Fakultesi Dergisi","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mehmet Akif Ersoy Universitesi Veteriner Fakultesi Dergisi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24880/maeuvfd.813073","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Middle ear diseases are common in cats. The aim of this study was to determine the normative tympanometric data of cats. Tympanometry, which provides objective data in the examination of the middle ear in humans, can be used as a supplementary examination, especially in cats with middle ear diseases where the external ear canal is normal. In this study, 30 healthy ears belonging to 15 cats which were classified as ASA-I (American Society of Anesthesiologyist) were determined and evaluated according to equivalent ear canal volume (Vea), static acoustic admittance [Ytm (compliance)], tympanometric peak pressure (TPP) and gradient values under general anesthesia. Tympanometric measurements obtained from right and left ears were 0.61 ± 0.12 ml and 0.60 ± 0.12 ml Vea, 0.31 ± 0.11 ml and 0.31 ± 0.11 ml Ytm, -11.2 ± 26.9 daPa and -14.9 ± 29.2 daPa TPP, 0.19 ± 0.11 ml and 0.24 ± 0.18 ml gradient respectively.Tympanometry as a supplementary examination is an easy to perform test in healthy cats with consistent results. It has the advantages of being completed in a short time, easy evaluation and providing information about middle ear without advanced imaging techniques. Results of this study represents the normative tympanometric measurements of cats which can be helpful distinguishing normal and abnormal conditions. Further studies needed to present exact values of standart tympanometric measurements and to introduce other variables like acustic refleks, wideband and multifrequency tympanometric results. 1Department of Surgery, Faculty of Veterinary Medicine, Burdur Mehmet Akif Ersoy University, Burdur/TURKEY MAE Vet Fak Derg, 5 (3): 131134, 2020 DOI: 10.24880/maeuvfd.813073 Bu makaleye atıfta bulunmak için/ To cite this article: YS ŞİRİN, Ö ŞENGÖZ-ŞİRİN. Normative ranges of tympanometric measurements in cats. MAE Vet Fak Derg. 2020; 5 (3) :131-134. INTRODUCTION Impedance audiometry has two main components: tympanometry and stapedius reflex measurement (1). Tympanometry is one of the most frequently performed and important components of the basic audiological evaluation. Objective middle ear assessment can best be performed by tympanometry (2). It measures how the middle-ear system responds to sound energy and changes in atmospheric pressure. It provides an objective, physiological measure of the acoustic admittance of the middle ear with the aid of air pressure in a sealed ear canal (3). The permeability and resistance of the middle ear system is defined with tympanometry via measuring the response to a sound stimulus using a microphone while pressure is changed along the external ear canal (4). The purpose of tympanometry is to asses audition on the basis of an objective description of the integrity and compliance of the eardrum, the mobility of the ossicular chain, the function of middle ear muscles and their attachments, and the size of the external ear canal (3). Data can be obtained from a tympanometer are estimated volume of air in front of the probe (equivalent ear canal volume, Vea), maximum compliance (Ytm), pressure at which the middle ear system has the greatest absorption of sound energy (TPP) and gradient of the tympanogram curve (5). Qualitative and quantitative approaches have been used in the interpretation of 226-Hz tympanograms (6). Tympanograms can most simply be classified as types A, B, and C depending on the curve shape compared to 0 as the pressure is changed (2). Further classification according to the shape of the curve is also used widely, type A as normal and type B, C, AD and AS as abnormal. Quantitative analysis of tympanograms is prefered, especially when evaluating infants and children, for whom different age-based normative values are needed (6). Definitions within modified Jerger classifications of tympanogram is described according to middle ear compliance (Ytm in ml) and middle ear pressure (TPP in daPa) as: type A (Ytm ≥0.2; TPP above –100), C1 (Ytm ≥0.2; TPP below or equal to –100 and above –200), C2 (Ytm ≥0.2; TPP below or equal to –100 and above –400) and B (Ytm <0.2; TPP below or equal to –400). Clinicians usually combine A and C1 as normal (7). The aim of this study was to evaluate the usefulness and consistency of the 226Hz tympanometer and its values in healthy cats. However, there are early tympanometry articles with cats, according to the authors knowledge these are the first published in vivo normal tympanometry values. MATERIAL and METHODS Cats brought to Mehmet Akif Ersoy University Animal Hospital for elective surgery without ear problems were included in the study. The study was approved by the Ethics Commission of Mehmet Akif Ersoy University. Fifteen mixed breed male (n: 7) and female (n: 8) cats at the age between 12-24 months included in the study. All cats were clinically Research Article
猫鼓室测量的标准范围
中耳疾病在猫身上很常见。本研究的目的是确定猫的标准鼓室测量数据。鼓室测量术为人类中耳检查提供了客观数据,可作为补充检查,尤其是在外耳道正常的患有中耳疾病的猫身上。在本研究中,根据等效耳道容积(Vea)、静态声导纳[Ytm(顺应性)]、鼓室压峰值(TPP)和全身麻醉下的梯度值,对15只猫的30只健康耳朵进行了测定和评估。从右耳和左耳获得的鼓室测量值分别为0.61±0.12 ml和0.60±0.12 ml Vea,0.31±0.11 ml和0.31±.11 ml Ytm,-11.2±26.9 daPa和-14.9±29.2 daPa TPP,0.19±0.11 ml和0.24±0.18 ml梯度。鼓室测量术作为一种补充检查,在健康猫身上是一种易于进行的测试,结果一致。它具有在短时间内完成、易于评估和提供中耳信息的优点,而无需先进的成像技术。这项研究的结果代表了猫的标准鼓室测量,有助于区分正常和异常情况。需要进一步的研究来提供标准鼓室测量的准确值,并引入其他变量,如听觉反射、宽带和多频鼓室测量结果。1 Burdur Mehmet Akif Ersoy大学兽医学院外科,Burdur/TURKEY MAE Vet Fak Derg,5(3):1311342020 DOI:10.24880/maeufd.813073 Bu makaleye atıfta bulunmak için/引用本文:YSŞ。猫鼓室测量的标准范围。MAE兽医假Derg。2020年;5(3):131-134。引言阻抗听力计有两个主要组成部分:鼓室测量和镫骨反射测量(1)。鼓室测量术是听力基础评估中最常进行的也是最重要的组成部分之一。目的中耳评估可以最好地进行鼓室测量(2)。它测量中耳系统对声能和大气压力变化的反应。它在密封耳道中的空气压力的帮助下提供了中耳声导纳的客观、生理测量(3)。中耳系统的渗透性和阻力是通过鼓室测量法来定义的,通过使用麦克风测量对声音刺激的响应,同时沿着外耳道改变压力(4)。鼓室测量的目的是在客观描述鼓膜的完整性和顺应性、听骨链的活动性、中耳肌及其附件的功能以及外耳道大小的基础上评估听力(3)。可以从鼓室计获得的数据是探头前方的估计空气体积(等效耳道体积Vea)、最大顺应性(Ytm)、中耳系统具有最大声能吸收的压力(TPP)和鼓室图曲线的梯度(5)。定性和定量方法已用于解释226赫兹鼓室图(6)。根据压力变化时与0相比的曲线形状,鼓室图可以最简单地分为A、B和C型(2)。根据曲线形状的进一步分类也被广泛使用,类型A为正常,类型B、C、AD和as为异常。鼓室图的定量分析是首选,尤其是在评估婴儿和儿童时,他们需要不同的基于年龄的标准值(6)。根据中耳顺应性(Ytm,单位为ml)和中耳压力(TPP,单位为daPa),鼓室图改良Jerger分类中的定义描述为:A型(Ytm≥0.2;TPP高于-100)、C1型(Ytm≥0.2;TPP低于或等于-100且高于-200)、C2型(Ytm≥0.2;TPP低于或等同-100且高于-400)和B型(Ytm<0.02;TPP低于或等于-400)。临床医生通常将A和C1合并为正常(7)。本研究的目的是评估226Hz鼓室压计的实用性和一致性及其在健康猫中的价值。然而,据作者所知,有关于猫的早期鼓室测量文章,这些是首次发表的体内正常鼓室测量值。材料和方法将被带到Mehmet Akif Ersoy大学动物医院进行择期手术但没有耳朵问题的猫纳入研究。这项研究得到了Mehmet Akif Ersoy大学伦理委员会的批准。研究中包括15只年龄在12-24个月之间的雄性(n:7)和雌性(n:8)混合品种的猫。所有猫都是临床研究文章
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
21
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书