Comparative study to evaluate the effect of intubation box on tracheal intubation difficulty with King Vision ® and TRUVIEW video laryngoscope in manikin in a tertiary care hospital

IF 0.2 Q4 ANESTHESIOLOGY
N. Nazir, A. Saxena
{"title":"Comparative study to evaluate the effect of intubation box on tracheal intubation difficulty with King Vision ® and TRUVIEW video laryngoscope in manikin in a tertiary care hospital","authors":"N. Nazir, A. Saxena","doi":"10.4038/slja.v30i1.8860","DOIUrl":null,"url":null,"abstract":"Background: The procedures related to airway can be associated with increased risk of aerosolization of SARS-CoV-2 virus posing a high risk to the personnels involved. Novel methods like the intubation box have been developed to increase the safety of healthcare workers during intubation. Methods: In this study, 33 anaesthesiologist and critical care specialists intubated the trachea of the airway manikin (US Laerdal Medical AS) 4 times using a King Vision ® videolaryngoscope and TRUVIEW PCD TM videolaryngoscope (with and without an intubation box as described by Lai). Intubation time was primary outcome. Secondary outcomes were first-pass intubation success rate, percentage of glottic opening (POGO) score and peak force to maxillary incisors measured with a pressure sensing device. Results: Intubation time and the pressure exerted on the incisors (detected by a click sound) were considerably higher in both groups when an intubation box was used. (Table 1) When comparing the two laryngoscopes, intubation time with the King Vision ® video laryngoscope was lower than that of TRUVIEW laryngoscope, both with and without the intubation box. (P<0.001) In both groups, rate of first pass successful intubation was higher without the intubation box, although the difference was statistically insignificant. POGO Score was not affected by intubation box but higher score was observed with King Vision ® laryngoscope. (Table 1,2). Conclusion: This study indicates that use of an intubation box makes intubation difficult and increases the time. King Vision ® videolaryngoscope results in lesser intubation time and better glottic view as compared to TRUVIEW laryngoscope.","PeriodicalId":41531,"journal":{"name":"Sri Lankan Journal of Anaesthesiology","volume":" ","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2022-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sri Lankan Journal of Anaesthesiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4038/slja.v30i1.8860","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The procedures related to airway can be associated with increased risk of aerosolization of SARS-CoV-2 virus posing a high risk to the personnels involved. Novel methods like the intubation box have been developed to increase the safety of healthcare workers during intubation. Methods: In this study, 33 anaesthesiologist and critical care specialists intubated the trachea of the airway manikin (US Laerdal Medical AS) 4 times using a King Vision ® videolaryngoscope and TRUVIEW PCD TM videolaryngoscope (with and without an intubation box as described by Lai). Intubation time was primary outcome. Secondary outcomes were first-pass intubation success rate, percentage of glottic opening (POGO) score and peak force to maxillary incisors measured with a pressure sensing device. Results: Intubation time and the pressure exerted on the incisors (detected by a click sound) were considerably higher in both groups when an intubation box was used. (Table 1) When comparing the two laryngoscopes, intubation time with the King Vision ® video laryngoscope was lower than that of TRUVIEW laryngoscope, both with and without the intubation box. (P<0.001) In both groups, rate of first pass successful intubation was higher without the intubation box, although the difference was statistically insignificant. POGO Score was not affected by intubation box but higher score was observed with King Vision ® laryngoscope. (Table 1,2). Conclusion: This study indicates that use of an intubation box makes intubation difficult and increases the time. King Vision ® videolaryngoscope results in lesser intubation time and better glottic view as compared to TRUVIEW laryngoscope.
在一家三级护理医院评估King Vision®和TRUVIEW视频喉镜在人体模型中插管箱对气管插管困难影响的比较研究
背景:与气道相关的程序可能会增加严重急性呼吸系统综合征冠状病毒2型病毒雾化的风险,对相关人员构成高风险。像插管盒这样的新方法已经被开发出来,以提高医护人员在插管过程中的安全性。方法:在本研究中,33名麻醉师和重症监护专家使用King Vision®视频喉镜和TRUVIEW PCD TM视频喉镜(如赖所述,带和不带插管盒)对气道模型(US Laerdal Medical AS)的气管插管4次。插管时间是主要结果。次要结果是首次插管成功率、声门开放(POGO)评分百分比和用压力传感设备测量的上颌切牙峰值力。结果:当使用插管盒时,两组的插管时间和施加在切牙上的压力(通过点击声检测)都要高得多。(表1)当比较两种喉镜时,无论有无插管盒,King Vision®视频喉镜的插管时间都低于TRUVIEW喉镜。(P<0.001)两组在不使用插管盒的情况下,首次插管成功率较高,但差异无统计学意义。POGO评分不受插管盒的影响,但King Vision®喉镜的评分更高。(表1,2)。结论:本研究表明,插管箱的使用增加了插管的难度和时间。与TRUVIEW喉镜相比,King Vision®视频喉镜插管时间更短,声门视野更好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
33
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书