Shendong Shi, Bala Muralikrishnan, Vincent Lee, Daniel Sawyer, Octavio Icasio-Hernández
{"title":"Improvised Long Test Lengths via Stitching Scale Bar Method: Performance Evaluation of Terrestrial Laser Scanners per ASTM E3125-17.","authors":"Shendong Shi, Bala Muralikrishnan, Vincent Lee, Daniel Sawyer, Octavio Icasio-Hernández","doi":"10.6028/jres.125.017","DOIUrl":null,"url":null,"abstract":"<p><p>Periodic performance evaluation is a critical issue for ensuring the reliability of data from terrestrial laser scanners (TLSs). With the recent introduction of the ASTM E3125-17 standard, there now exist standardized test procedures for this purpose. Point-to-point length measurement is one test method described in that documentary standard. This test is typically performed using a long scale bar (typically 2 m or longer) with spherical targets mounted on both ends. Long scale bars can become unwieldy and vary in length due to gravity loading, fixture forces, and environmental changes. In this paper, we propose a stitching scale bar (SSB) method in which a short scale bar (approximately 1 m or smaller) can provide a spatial length reference several times its length. The clear advantages of a short scale bar are that it can be calibrated in a laboratory and has potential long-term stability. An essential requirement when stitching a short scale bar is that the systematic errors in TLSs do not change significantly over short distances. We describe this requirement in this paper from both theoretical and experimental perspectives. Based on this SSB method, we evaluate the performance of a TLS according to the ASTM E3125-17 standard by stitching a 1.15 m scale bar to form a 2.3 m reference length. For comparison, a single 2.3 m scale bar is also employed for direct measurements without stitching. Experimental results show a maximum deviation of 0.072 mm in length errors between the two approaches, which is an order of magnitude smaller than typical accuracy specifications for TLSs.</p>","PeriodicalId":54766,"journal":{"name":"Journal of Research of the National Institute of Standards and Technology","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2020-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10871170/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Research of the National Institute of Standards and Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.6028/jres.125.017","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0
Abstract
Periodic performance evaluation is a critical issue for ensuring the reliability of data from terrestrial laser scanners (TLSs). With the recent introduction of the ASTM E3125-17 standard, there now exist standardized test procedures for this purpose. Point-to-point length measurement is one test method described in that documentary standard. This test is typically performed using a long scale bar (typically 2 m or longer) with spherical targets mounted on both ends. Long scale bars can become unwieldy and vary in length due to gravity loading, fixture forces, and environmental changes. In this paper, we propose a stitching scale bar (SSB) method in which a short scale bar (approximately 1 m or smaller) can provide a spatial length reference several times its length. The clear advantages of a short scale bar are that it can be calibrated in a laboratory and has potential long-term stability. An essential requirement when stitching a short scale bar is that the systematic errors in TLSs do not change significantly over short distances. We describe this requirement in this paper from both theoretical and experimental perspectives. Based on this SSB method, we evaluate the performance of a TLS according to the ASTM E3125-17 standard by stitching a 1.15 m scale bar to form a 2.3 m reference length. For comparison, a single 2.3 m scale bar is also employed for direct measurements without stitching. Experimental results show a maximum deviation of 0.072 mm in length errors between the two approaches, which is an order of magnitude smaller than typical accuracy specifications for TLSs.
期刊介绍:
The Journal of Research of the National Institute of Standards and Technology is the flagship publication of the National Institute of Standards and Technology. It has been published under various titles and forms since 1904, with its roots as Scientific Papers issued as the Bulletin of the Bureau of Standards.
In 1928, the Scientific Papers were combined with Technologic Papers, which reported results of investigations of material and methods of testing. This new publication was titled the Bureau of Standards Journal of Research.
The Journal of Research of NIST reports NIST research and development in metrology and related fields of physical science, engineering, applied mathematics, statistics, biotechnology, information technology.