M. Vorlíček, T. Stewart, J. Dygrýn, L. Rubín, J. Mitáš, J. Schipperijn
{"title":"The comparison of Holux and Qstarz GPS receivers in free living conditions: Dynamic accuracy in different active transport modes","authors":"M. Vorlíček, T. Stewart, J. Dygrýn, L. Rubín, J. Mitáš, J. Schipperijn","doi":"10.5507/AG.2019.009","DOIUrl":null,"url":null,"abstract":"Background: Physical activity (PA) is one of the major factors influencing human health. An important group of determinants are elements forming the built environment. For a proper understanding of relationships between the built environment and PA, we need to measure PA in space. Objective: This study aims to verify the accuracy of the Holux RCV-3000 GPS logger, which has not yet been validated in relation with PA. Methods: Two GPS receivers (Holux RCV-3000 and already validated Qstarz BT-Q1000XT) were tested during walking, running and cycling. A total of 1,908 GPS points were recorded by each device. For each trip, we calculated the percentage of points that fell within 1, 2.5, 5, and 10 m buffers, as well as the mean and median error. Results: Our results showed that 53.1% of all Holux and 45.1% of Qstarz GPS points fell within 2.5 m of the expected location, 90% (Holux) and 80% (Qstarz) fell within 10 m and the median error was 2.33 m and 3.15 m, respectively. Conclusions: The dynamic spatial accuracy of the tested Holux RCV-3000 was better than more expensive Qstarz device and can be considered as a valid instrument for assessing the spatial location of PA in future work.","PeriodicalId":51894,"journal":{"name":"Acta Gymnica","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2019-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Gymnica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5507/AG.2019.009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 2
Abstract
Background: Physical activity (PA) is one of the major factors influencing human health. An important group of determinants are elements forming the built environment. For a proper understanding of relationships between the built environment and PA, we need to measure PA in space. Objective: This study aims to verify the accuracy of the Holux RCV-3000 GPS logger, which has not yet been validated in relation with PA. Methods: Two GPS receivers (Holux RCV-3000 and already validated Qstarz BT-Q1000XT) were tested during walking, running and cycling. A total of 1,908 GPS points were recorded by each device. For each trip, we calculated the percentage of points that fell within 1, 2.5, 5, and 10 m buffers, as well as the mean and median error. Results: Our results showed that 53.1% of all Holux and 45.1% of Qstarz GPS points fell within 2.5 m of the expected location, 90% (Holux) and 80% (Qstarz) fell within 10 m and the median error was 2.33 m and 3.15 m, respectively. Conclusions: The dynamic spatial accuracy of the tested Holux RCV-3000 was better than more expensive Qstarz device and can be considered as a valid instrument for assessing the spatial location of PA in future work.
期刊介绍:
The journal "Acta Gymnica" (ISSN 2336-4912 (Print); ISSN 2336-4920 (On-line)), published formerly as "Acta Universitatis Palackianae Olomucensis. Gymnica" (ISSN 1212-1185 (Print); ISSN 1213-8312 (On-line)), focuses on presenting results of research studies and theoretical studies from the field of kinanthropology. The scope of the journal covers topics related to biomechanics, exercise physiology, physiotherapy, somatometry, sports psychology, sports training, physical education, public health, etc. The journal also welcomes submissions that present results of interdisciplinary research.