Study of some alcohol amounts in commercial alcoholic disinfectant solutions using gas chromatography with flame ionization detection

Masoumeh Darbanian, A. Nezhadali, V. Rahimi
{"title":"Study of some alcohol amounts in commercial alcoholic disinfectant solutions using gas chromatography with flame ionization detection","authors":"Masoumeh Darbanian, A. Nezhadali, V. Rahimi","doi":"10.5155/eurjchem.13.3.279-283.2240","DOIUrl":null,"url":null,"abstract":"A simple solvent extraction method was used to analyze alcohol-based hand rubs (ABHRs) using gas chromatography with a flame ionization detector. 79 samples including 68 liquid and 11-gelled ABHRs were analyzed in the Food and Drug Laboratories Research Center of Mashhad, Iran. 17 samples had methanol, 50 samples had the correct percentage of alcohol (60-80%), and 12 samples had the incorrect percentage of alcohol (<60%). The RSD% of methanol, ethanol, and isopropanol were as 2.28, 2.18, and 1.52, respectively. The relative recoveries for methanol, ethanol, and isopropanol were 102.5, 97.8, and 114, respectively. All experiments were repeated three times. The limit of detection and the limit of quantification for methanol, ethanol, and isopropanol were obtained as 0.22, 0.24, 0.10 (%) and 0.71, 0.82, 0.68 (%), respectively.","PeriodicalId":89364,"journal":{"name":"European journal of chemistry (Print)","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of chemistry (Print)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5155/eurjchem.13.3.279-283.2240","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A simple solvent extraction method was used to analyze alcohol-based hand rubs (ABHRs) using gas chromatography with a flame ionization detector. 79 samples including 68 liquid and 11-gelled ABHRs were analyzed in the Food and Drug Laboratories Research Center of Mashhad, Iran. 17 samples had methanol, 50 samples had the correct percentage of alcohol (60-80%), and 12 samples had the incorrect percentage of alcohol (<60%). The RSD% of methanol, ethanol, and isopropanol were as 2.28, 2.18, and 1.52, respectively. The relative recoveries for methanol, ethanol, and isopropanol were 102.5, 97.8, and 114, respectively. All experiments were repeated three times. The limit of detection and the limit of quantification for methanol, ethanol, and isopropanol were obtained as 0.22, 0.24, 0.10 (%) and 0.71, 0.82, 0.68 (%), respectively.
用气相色谱-火焰离子化检测法研究商用酒精消毒剂溶液中的某些酒精含量
采用一种简单的溶剂萃取方法,使用火焰离子化检测器的气相色谱法分析酒精基手擦(ABHR)。在伊朗马什哈德的食品和药物实验室研究中心分析了79个样品,包括68个液体和11个凝胶ABHR。17个样品含有甲醇,50个样品含有正确的酒精百分比(60-80%),12个样品含有不正确的酒精比例(<60%)。甲醇、乙醇和异丙醇的RSD%分别为2.28、2.18和1.52。甲醇、乙醇和异丙醇的相对回收率分别为102.5、97.8和114。所有实验都重复了三次。甲醇、乙醇和异丙醇的检测限和定量限分别为0.22、0.24、0.10(%)和0.71、0.82、0.68(%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信