Resolution-intensity optimisation on quasielastic neutron scattering spectrometers

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
R. Zorn
{"title":"Resolution-intensity optimisation on quasielastic neutron scattering spectrometers","authors":"R. Zorn","doi":"10.3233/jnr-210029","DOIUrl":null,"url":null,"abstract":"In quasieleastic neutron scattering spectrometers one usually faces a trade-off between energy resolution and counting statistics. If the resolution is improved the intensity at the detectors reduces and vice versa. It is not immediately clear how to weigh both factors against each other. In this paper it is proposed to use the maximum time obtainable by Fourier transform of the spectra as the quantity to be optimised. It is shown that this leads to a well-defined criterion for the choice of the resolution.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2021-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3233/jnr-210029","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

In quasieleastic neutron scattering spectrometers one usually faces a trade-off between energy resolution and counting statistics. If the resolution is improved the intensity at the detectors reduces and vice versa. It is not immediately clear how to weigh both factors against each other. In this paper it is proposed to use the maximum time obtainable by Fourier transform of the spectra as the quantity to be optimised. It is shown that this leads to a well-defined criterion for the choice of the resolution.
准弹性中子散射光谱仪的分辨率强度优化
在准弹性中子散射光谱仪中,人们通常面临能量分辨率和计数统计之间的权衡。如果分辨率提高,探测器处的强度降低,反之亦然。目前还不清楚如何权衡这两个因素。本文提出用谱的傅里叶变换得到的最大时间作为优化量。结果表明,这导致了一个明确定义的分辨率选择标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信