Effect of maximum grain size on value of modulus of rupture reactive powder concrete

W. Kushartomo, Dewi Linggasari, Arianti Sutandi
{"title":"Effect of maximum grain size on value of modulus of rupture reactive powder concrete","authors":"W. Kushartomo, Dewi Linggasari, Arianti Sutandi","doi":"10.14710/mkts.v26i1.25088","DOIUrl":null,"url":null,"abstract":"Modulus of rupture (R) is a measurement of a tensile strengh of a concrete beam. The value of R is affected by the size of fine aggregat grain, the density of the concrete beam and the water-cement ratio. The unit of R is MPa expressing the tensile strength of the concrete beam without reinforcement to withstand a buckling failure. The distance between the supports of the concrete beam should not be less than three times of the height of the beam. In this research the size of the concrete beam speciment was 100 mm x 100 mm x 350 mm, the maximum fine aggregate size was varied (300 µm, 425 µm, and 600 µm) and the water-cement ratio was also varied (0.25, 0.22 and 0,20). All speciments were cured by steam curing and were tested after seven days. The results show that the larger the size of the fine aggregat grain and the higher the water-cement ratio, the smaller the R.","PeriodicalId":31880,"journal":{"name":"Media Komunikasi Teknik Sipil","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.14710/mkts.v26i1.25088","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Media Komunikasi Teknik Sipil","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14710/mkts.v26i1.25088","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Modulus of rupture (R) is a measurement of a tensile strengh of a concrete beam. The value of R is affected by the size of fine aggregat grain, the density of the concrete beam and the water-cement ratio. The unit of R is MPa expressing the tensile strength of the concrete beam without reinforcement to withstand a buckling failure. The distance between the supports of the concrete beam should not be less than three times of the height of the beam. In this research the size of the concrete beam speciment was 100 mm x 100 mm x 350 mm, the maximum fine aggregate size was varied (300 µm, 425 µm, and 600 µm) and the water-cement ratio was also varied (0.25, 0.22 and 0,20). All speciments were cured by steam curing and were tested after seven days. The results show that the larger the size of the fine aggregat grain and the higher the water-cement ratio, the smaller the R.
最大粒径对断裂活性粉混凝土模量的影响
断裂模量(R)是测量混凝土梁的抗拉强度。R值受细骨料粒度、混凝土梁密度和水灰比的影响。R的单位为MPa,表示不加筋的混凝土梁在屈曲破坏时的抗拉强度。混凝土梁支座之间的距离不应小于梁高度的三倍。在本研究中,混凝土梁试件尺寸为100 mm × 100 mm × 350 mm,最大细骨料尺寸为300µm、425µm和600µm,水灰比为0.25、0.22和0.20。所有样品均采用蒸汽固化,7天后进行测试。结果表明:细骨料粒径越大、水灰比越高,R值越小;
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书