{"title":"Influence of Phosphoric Acid Etching on the Bond Strength of a Universal Adhesive System to Caries-Affected Dentin","authors":"R. Pavanello, S. Pinheiro","doi":"10.4236/abc.2018.83004","DOIUrl":null,"url":null,"abstract":"The purpose of this study was to evaluate the influence of acid etching on the bond strength of a universal adhesive system (Single Bond Universal, 3M) to caries-affected dentin. Forty permanent third molars were selected and carious lesions were induced by the microbiological method with S. mutans ATCC25175. Teeth were allocated randomly across four experimental designs (n = 10): PA-I: phosphoric acid etching and application of the adhesive system, followed by immediate microtensile bond strength testing; PA-CC: phosphoric acid etching and application of the adhesive system, followed by microtensile bond strength testing after a 14-day cariogenic challenge; NPA-I: application of the adhesive system without acid etching, followed by immediate bond strength testing and NPA-CC: application of the adhesive system without acid etching followed by bond strength testing after 14-day cariogenic challenge. For microtensile bond strength testing, a restoration with Charisma composite resin was made and each specimen was sectioned with a cross-sectional area of 1 mm2. Only adhesive and mixed fractures were considered for bond strength calculation. Results were evaluated by the Kruskal-Wallis and Friedman tests. The highest bond strengths were observed in the phosphoric acid etching groups (p 0.05). The predominant fracture type was adhesive. We conclude that phosphoric acid increased the bond strength of the Single Bond Universal system to caries-affected dentin, and that cariogenic challenge did not interfere with this bond strength.","PeriodicalId":59114,"journal":{"name":"生物化学进展(英文)","volume":"08 1","pages":"37-46"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"生物化学进展(英文)","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.4236/abc.2018.83004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The purpose of this study was to evaluate the influence of acid etching on the bond strength of a universal adhesive system (Single Bond Universal, 3M) to caries-affected dentin. Forty permanent third molars were selected and carious lesions were induced by the microbiological method with S. mutans ATCC25175. Teeth were allocated randomly across four experimental designs (n = 10): PA-I: phosphoric acid etching and application of the adhesive system, followed by immediate microtensile bond strength testing; PA-CC: phosphoric acid etching and application of the adhesive system, followed by microtensile bond strength testing after a 14-day cariogenic challenge; NPA-I: application of the adhesive system without acid etching, followed by immediate bond strength testing and NPA-CC: application of the adhesive system without acid etching followed by bond strength testing after 14-day cariogenic challenge. For microtensile bond strength testing, a restoration with Charisma composite resin was made and each specimen was sectioned with a cross-sectional area of 1 mm2. Only adhesive and mixed fractures were considered for bond strength calculation. Results were evaluated by the Kruskal-Wallis and Friedman tests. The highest bond strengths were observed in the phosphoric acid etching groups (p 0.05). The predominant fracture type was adhesive. We conclude that phosphoric acid increased the bond strength of the Single Bond Universal system to caries-affected dentin, and that cariogenic challenge did not interfere with this bond strength.
本研究的目的是评估酸蚀对通用粘合剂系统(Single bond universal,3M)与受龋齿影响的牙本质的粘合强度的影响。选用40颗第三恒磨牙,用S。突变株ATCC25175。将牙齿随机分配到四个实验设计中(n=10):PA-I:磷酸蚀刻和粘合剂系统的应用,然后立即进行微拉伸粘合强度测试;PA-CC:磷酸蚀刻和粘合剂系统的应用,然后在14天致龋攻击后进行微拉伸结合强度测试;NPA-I:在不进行酸蚀刻的情况下施用粘合剂系统,然后立即进行结合强度测试;NPA-CC:在14天致龋攻击后施用不进行酸蚀的粘合剂系统,随后进行结合强度试验。对于微拉伸结合强度测试,用Charisma复合树脂制作修复体,并以1mm2的横截面积对每个样品进行切片。粘结强度计算只考虑了粘结裂缝和混合裂缝。结果通过Kruskal-Wallis和Friedman检验进行评估。磷酸蚀刻组的结合强度最高(p 0.05)。主要的断裂类型是粘合剂。我们得出的结论是,磷酸增加了Single bond Universal系统与受龋齿影响的牙本质的结合强度,并且致龋挑战不会干扰这种结合强度。