A novel and simple design of the closing loop producing optimal force magnitude and moment-to-force ratio for en-masse retraction of anterior teeth

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE
S. Yamaoka, R. Hamanaka, T. Nguyen, Sachio Jinnai, Junya Tominaga, Y. Koga, N. Yoshida
{"title":"A novel and simple design of the closing loop producing optimal force magnitude and moment-to-force ratio for en-masse retraction of anterior teeth","authors":"S. Yamaoka, R. Hamanaka, T. Nguyen, Sachio Jinnai, Junya Tominaga, Y. Koga, N. Yoshida","doi":"10.1080/13440241.2020.1770558","DOIUrl":null,"url":null,"abstract":"ABSTRACT Purpose: The aim of this study was to clarify the mechanical conditions of loop activation that produce the optimal force system allowing controlled movement of the anterior teeth. Materials and Methods: The closing loop examined in this study was a 10-mm-high teardrop type bent from a 0.017 × 0.025-inch stainless steel archwire. A loop design that can generate a high moment-to-force (M/F) ratio and the optimal force magnitude was investigated by varying the rate of the cross-sectional reduction of the loop apex, the amount of loop activation and the degree of gable bend. Forces and moments acting on closing loops were calculated using structural analysis based on the tangent stiffness method. Results: A force magnitude of 302 g and an M/F ratio higher than 10 (sufficiently high to achieve bodily movement of the anterior teeth) could be produced when the thickness of the cross-section of a 10-mm-high teardrop loop was reduced by half for a distance of 3 mm from the apex and a gable bend of 30° was incorporated into the loop. Conclusions: The optimal force magnitude and M/F ratio for achieving controlled tipping or bodily movement of the anterior teeth can be produced by partially reducing the thickness of the teardrop loop, and by placing a gable bend of 20° to 30° in the 0.018-inch bracket slot system.","PeriodicalId":43169,"journal":{"name":"Orthodontic Waves","volume":"79 1","pages":"77 - 82"},"PeriodicalIF":0.5000,"publicationDate":"2020-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/13440241.2020.1770558","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthodontic Waves","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/13440241.2020.1770558","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

Abstract

ABSTRACT Purpose: The aim of this study was to clarify the mechanical conditions of loop activation that produce the optimal force system allowing controlled movement of the anterior teeth. Materials and Methods: The closing loop examined in this study was a 10-mm-high teardrop type bent from a 0.017 × 0.025-inch stainless steel archwire. A loop design that can generate a high moment-to-force (M/F) ratio and the optimal force magnitude was investigated by varying the rate of the cross-sectional reduction of the loop apex, the amount of loop activation and the degree of gable bend. Forces and moments acting on closing loops were calculated using structural analysis based on the tangent stiffness method. Results: A force magnitude of 302 g and an M/F ratio higher than 10 (sufficiently high to achieve bodily movement of the anterior teeth) could be produced when the thickness of the cross-section of a 10-mm-high teardrop loop was reduced by half for a distance of 3 mm from the apex and a gable bend of 30° was incorporated into the loop. Conclusions: The optimal force magnitude and M/F ratio for achieving controlled tipping or bodily movement of the anterior teeth can be produced by partially reducing the thickness of the teardrop loop, and by placing a gable bend of 20° to 30° in the 0.018-inch bracket slot system.
一种新颖简单的闭合环设计,可产生最佳的力大小和力矩-力比,用于前牙整体回缩
摘要目的:本研究的目的是阐明环激活的机械条件,以产生允许前牙受控运动的最佳力系统。材料和方法:本研究中检查的闭合环是由0.017×0.025英寸不锈钢弓丝弯曲而成的10mm高的泪滴型闭合环。通过改变环顶点的横截面减小率、环激活量和山墙弯曲程度,研究了一种可以产生高力矩与力(M/F)比和最佳力大小的环设计。采用基于切线刚度法的结构分析计算了作用在闭合环上的力和力矩。结果:当10 mm高泪滴环的横截面厚度在距离顶端3 mm处减少一半,并且在环中加入30°的山形弯曲时,可以产生302 g的力大小和高于10的M/F比(足够高以实现前牙的身体运动)。结论:通过部分减少泪滴环的厚度,并在0.018英寸的托槽槽系统中放置20°至30°的山形弯曲,可以产生实现前牙受控倾翻或身体运动的最佳力大小和M/F比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Orthodontic Waves
Orthodontic Waves DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
0.40
自引率
0.00%
发文量
0
期刊介绍: Orthodontic Waves is the official publication of the Japanese Orthodontic Society. The aim of this journal is to foster the advancement of orthodontic research and practice. The journal seeks to publish original articles (i) definitive reports of wide interest to the orthodontic community, (ii) Case Reports and (iii) Short Communications. Research papers stand on the scientific basis of orthodontics. Clinical topics covered include all techniques and approaches to treatment planning. All submissions are subject to peer review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信