Morphometric Study of Distal End of Human Dry Radii

Muna Kadel, T. Thapa
{"title":"Morphometric Study of Distal End of Human Dry Radii","authors":"Muna Kadel, T. Thapa","doi":"10.3126/MJSBH.V20I1.27943","DOIUrl":null,"url":null,"abstract":"Introduction: Radius is the lateral bone of forearm. Important parameters of its distal end include angle of radial inclination, palmar tilt, and length of radial styloid process. Morphometry of the distal end of radius is important in various clinical orthopaedic procedures such as reduction of distal radius fractures, design of distal radius prosthesis, and kinematics of the wrist joint. The aim of this study is to determine the angle of radial inclination, palmar tilt, length of styloid process, oblique width, transverse and anteroposterior diameter of distal end of human dry radii in Nepalese population. Methods: This is a descriptive cross-sectional study conducted in the dissection hall of Department of Human Anatomy, Nepalese Army Institute of Health Sciences, Sanobhyrang, Kathmandu, Nepal from October 2019 to November 2019 after obtaining ethical approval. Total 76 human dry radii were included in the study by convenience sampling method. Angle of radial inclination, palmar tilt, length of styloid process, oblique width, transverse and anteroposterior diameter of distal end of human dry radii were studied. Data was collected and analysed by SPSS version 24. Results: Mean length of styloid process was 1.09 cm. Mean anteroposterior and transverse diameter of distal end of radius was 1.88 cm and 2.85 cm respectively. Mean oblique width of distal radius was 2.82 cm. The mean palmar tilt and angle of inclination of radius were 9.72 and 23.62 degree respectively. Conclusions: This study provides the reference data for the anatomical alignment while treating the injuries of the distal end of radius in Nepalese population.","PeriodicalId":33963,"journal":{"name":"Medical Journal of Shree Birendra Hospital","volume":"20 1","pages":"36-40"},"PeriodicalIF":0.0000,"publicationDate":"2021-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Journal of Shree Birendra Hospital","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3126/MJSBH.V20I1.27943","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Introduction: Radius is the lateral bone of forearm. Important parameters of its distal end include angle of radial inclination, palmar tilt, and length of radial styloid process. Morphometry of the distal end of radius is important in various clinical orthopaedic procedures such as reduction of distal radius fractures, design of distal radius prosthesis, and kinematics of the wrist joint. The aim of this study is to determine the angle of radial inclination, palmar tilt, length of styloid process, oblique width, transverse and anteroposterior diameter of distal end of human dry radii in Nepalese population. Methods: This is a descriptive cross-sectional study conducted in the dissection hall of Department of Human Anatomy, Nepalese Army Institute of Health Sciences, Sanobhyrang, Kathmandu, Nepal from October 2019 to November 2019 after obtaining ethical approval. Total 76 human dry radii were included in the study by convenience sampling method. Angle of radial inclination, palmar tilt, length of styloid process, oblique width, transverse and anteroposterior diameter of distal end of human dry radii were studied. Data was collected and analysed by SPSS version 24. Results: Mean length of styloid process was 1.09 cm. Mean anteroposterior and transverse diameter of distal end of radius was 1.88 cm and 2.85 cm respectively. Mean oblique width of distal radius was 2.82 cm. The mean palmar tilt and angle of inclination of radius were 9.72 and 23.62 degree respectively. Conclusions: This study provides the reference data for the anatomical alignment while treating the injuries of the distal end of radius in Nepalese population.
人体干桡骨远端形态计量学研究
桡骨是前臂的外侧骨。其远端主要参数包括径向倾角、手掌倾角和径向茎突长度。桡骨远端形态测量在各种临床骨科手术中都很重要,如桡骨远端骨折复位、桡骨远端假体设计和腕关节运动学。本研究的目的是确定尼泊尔人群干桡骨远端径向倾斜角、手掌倾斜角、茎突长度、斜宽度、横向直径和前后直径。方法:本研究是一项描述性横断面研究,经伦理批准,于2019年10月至2019年11月在尼泊尔加德满都Sanobhyrang尼泊尔陆军卫生科学研究所人体解剖学系解剖厅进行。采用方便抽样法,共纳入76例人体干半径。研究了人体干桡骨远端径向倾角、手掌倾角、茎突长度、斜向宽度、横向直径和前后直径。数据收集和分析采用SPSS version 24。结果:茎突平均长度为1.09 cm。桡骨远端平均正、横径分别为1.88 cm和2.85 cm。桡骨远端平均斜宽度为2.82 cm。手掌平均倾斜度为9.72度,桡骨倾斜角为23.62度。结论:本研究为尼泊尔人群桡骨远端损伤的解剖对准提供了参考数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
25
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信