{"title":"Evaluation of sensitivity and specificity of high fluorescence lymphocyte count percentage of sysmex XN analyzer in diagnosis of dengue","authors":"Aparna Ningombam, S. Acharya, Abhirup Sarkar, Kundan Kumar, M. Brijwal, Srimantinee Routray, J. Sachdev, D. Srigyan, Aashish Choudhary, A. Subramanian, L. Dar","doi":"10.4103/joah.joah_204_20","DOIUrl":null,"url":null,"abstract":"BACKGROUND: The Sysmex XN-series hematology analyzers provide newer parameters including high fluorescence lymphocyte cell percentage (HFLC%) which correlates with the presence of atypical lymphocytes in peripheral blood. We aimed to analyze the sensitivity and specificity of HFLC% as a diagnostic tool and its association with serological status in diagnosed dengue patients and thereby establish a cutoff of HFLC% based on serology. Besides, we also wish to correlate HFLC% with thrombocytopenia in these patients. MATERIALS AND METHODS: A total of 1500 serum samples were subjected to serological evaluation for dengue. After excluding hematological malignancies and autoimmune disorders, the same day complete blood count parameters including HFLC% and platelet counts were collected retrospectively for 292 serologically positive dengue cases and 76 seronegative controls. RESULTS: Our result shows that in nonstructural 1 antigen-positive cases, a cutoff of >5.2% HFLC can have a sensitivity of 79.5% and specificity of 98.6%. We found a different cut off of HFLC% >3.2% (sensitivity 83.4%, specificity 98.6%) for the cases with only immunoglobulin M positivity and a cut off of HFLC% >2.6% (sensitivity 86.1%, specificity 96%) in the dual positive cases (immunoglobulin M with nonstructural 1 antigen). Besides, high HFLC% also shows a strong correlation with platelet count with a Spearman correlation coefficient of −0.6. CONCLUSIONS: The result of our study shows that a specific cutoff of HFLC% can not only help us to suspect dengue fever but also predict the risk of thrombocytopenia in already diagnosed dengue patients. The sensitivity and specificity of HFLC% varied with the serological status of the patients which depend on the days of fever on presentation.","PeriodicalId":36501,"journal":{"name":"Journal of Applied Hematology","volume":"13 1","pages":"132 - 138"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Hematology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/joah.joah_204_20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1

Abstract

BACKGROUND: The Sysmex XN-series hematology analyzers provide newer parameters including high fluorescence lymphocyte cell percentage (HFLC%) which correlates with the presence of atypical lymphocytes in peripheral blood. We aimed to analyze the sensitivity and specificity of HFLC% as a diagnostic tool and its association with serological status in diagnosed dengue patients and thereby establish a cutoff of HFLC% based on serology. Besides, we also wish to correlate HFLC% with thrombocytopenia in these patients. MATERIALS AND METHODS: A total of 1500 serum samples were subjected to serological evaluation for dengue. After excluding hematological malignancies and autoimmune disorders, the same day complete blood count parameters including HFLC% and platelet counts were collected retrospectively for 292 serologically positive dengue cases and 76 seronegative controls. RESULTS: Our result shows that in nonstructural 1 antigen-positive cases, a cutoff of >5.2% HFLC can have a sensitivity of 79.5% and specificity of 98.6%. We found a different cut off of HFLC% >3.2% (sensitivity 83.4%, specificity 98.6%) for the cases with only immunoglobulin M positivity and a cut off of HFLC% >2.6% (sensitivity 86.1%, specificity 96%) in the dual positive cases (immunoglobulin M with nonstructural 1 antigen). Besides, high HFLC% also shows a strong correlation with platelet count with a Spearman correlation coefficient of −0.6. CONCLUSIONS: The result of our study shows that a specific cutoff of HFLC% can not only help us to suspect dengue fever but also predict the risk of thrombocytopenia in already diagnosed dengue patients. The sensitivity and specificity of HFLC% varied with the serological status of the patients which depend on the days of fever on presentation.
sysmex XN高荧光淋巴细胞计数百分比分析仪诊断登革热的敏感性和特异性评价
背景:Sysmex XN系列血液分析仪提供了新的参数,包括与外周血中非典型淋巴细胞存在相关的高荧光淋巴细胞百分比(HFLC%)。我们旨在分析HFLC%作为诊断工具的敏感性和特异性,以及它与确诊登革热患者血清学状态的关系,从而根据血清学确定HFLC%的临界值。此外,我们还希望将HFLC%与这些患者的血小板减少症联系起来。材料和方法:对1500份血清样本进行登革热血清学评价。在排除血液系统恶性肿瘤和自身免疫性疾病后,对292例血清阳性登革热病例和76例血清阴性对照进行了当天的完整血液计数参数(包括HFLC%和血小板计数)的回顾性收集。结果:在非结构1抗原阳性病例中,HFLC的临界值>5.2%可具有79.5%的灵敏度和98.6%的特异性。我们发现,对于仅免疫球蛋白M阳性的病例,HFLC%>3.2%(灵敏度83.4%,特异性98.6%)的临界值不同,而对于双阳性病例(具有非结构1抗原的免疫球蛋白),HFLC%的临界值>2.6%(灵敏度86.1%,特异性96%)。此外,高HFLC%也显示出与血小板计数的强相关性,Spearman相关系数为-0.6。结论:我们的研究结果表明,HFLC%的特定临界值不仅可以帮助我们怀疑登革热,还可以预测已经诊断的登革热患者出现血小板减少症的风险。HFLC%的敏感性和特异性随患者的血清学状态而变化,这取决于发热的天数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Applied Hematology
Journal of Applied Hematology Medicine-Hematology
CiteScore
0.40
自引率
0.00%
发文量
34
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信