Cavernosal artery peak systolic velocity among normal adults in Abuja, Nigeria: A Baseline parameter for sonographic diagnosis of vasculogenic erectile dysfunction

IF 0.1 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
J. Aiyekomogbon, O. Aisuodionoe-Shadrach
{"title":"Cavernosal artery peak systolic velocity among normal adults in Abuja, Nigeria: A Baseline parameter for sonographic diagnosis of vasculogenic erectile dysfunction","authors":"J. Aiyekomogbon, O. Aisuodionoe-Shadrach","doi":"10.4103/WAJR.WAJR_50_17","DOIUrl":null,"url":null,"abstract":"Background: Erectile dysfunction is consistent inability to achieve and maintain erection of sufficient rigidity for satisfactory sexual performance. It is well known that the hemodynamic function of the penis correlates well with the peak systolic velocity (PSV) of the cavernosal artery (CA) which is the most reliable, sensitive, and objective parameter used in evaluating the state of the erectile tissues of the penis. This study was aimed at establishing the normal CA PSV in this environment, as it may differ from the values among Americans, Caucasians, and Asians. Materials and Methods: The study was conducted between July 2015 and January 2017, at the Department of Radiology, Federal Medical Centre, Abuja. Twenty-nine consecutive patients referred by the urologist to the radiology department of the aforementioned institution for penile ultrasound were evaluated using triplex Doppler sonography with high-frequency linear array transducer. The penile scan was done before and after intracavernosal injection of 10–20 μg prostaglandin E1. The waveforms of CAs were obtained alternately using the angle of inclination ≤60°, and the PSV of the CA was documented at 5-min interval, from 5 to 40 min. Results: PSV of CA varied between 26 and 104.4 cm/s (mean: 46.72 ± 16.21) among the entire research participants. No significant discrepancy was noted between PSV of the right and left cavernosal arteries. The PSV had a strong positive relationship with age (P = 0.002), with the highest values found among those ≤30 years. Conclusion: The mean PSV of cavernosal arteries established in this study is not significantly different from the values obtained among Americans, Caucasians, and Asians, indicating that racial difference has no effect on this important sonographic variable.","PeriodicalId":29875,"journal":{"name":"West African Journal of Radiology","volume":null,"pages":null},"PeriodicalIF":0.1000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"West African Journal of Radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/WAJR.WAJR_50_17","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 2

Abstract

Background: Erectile dysfunction is consistent inability to achieve and maintain erection of sufficient rigidity for satisfactory sexual performance. It is well known that the hemodynamic function of the penis correlates well with the peak systolic velocity (PSV) of the cavernosal artery (CA) which is the most reliable, sensitive, and objective parameter used in evaluating the state of the erectile tissues of the penis. This study was aimed at establishing the normal CA PSV in this environment, as it may differ from the values among Americans, Caucasians, and Asians. Materials and Methods: The study was conducted between July 2015 and January 2017, at the Department of Radiology, Federal Medical Centre, Abuja. Twenty-nine consecutive patients referred by the urologist to the radiology department of the aforementioned institution for penile ultrasound were evaluated using triplex Doppler sonography with high-frequency linear array transducer. The penile scan was done before and after intracavernosal injection of 10–20 μg prostaglandin E1. The waveforms of CAs were obtained alternately using the angle of inclination ≤60°, and the PSV of the CA was documented at 5-min interval, from 5 to 40 min. Results: PSV of CA varied between 26 and 104.4 cm/s (mean: 46.72 ± 16.21) among the entire research participants. No significant discrepancy was noted between PSV of the right and left cavernosal arteries. The PSV had a strong positive relationship with age (P = 0.002), with the highest values found among those ≤30 years. Conclusion: The mean PSV of cavernosal arteries established in this study is not significantly different from the values obtained among Americans, Caucasians, and Asians, indicating that racial difference has no effect on this important sonographic variable.
尼日利亚阿布贾正常成年人海绵体动脉收缩速度峰值:超声诊断血管源性勃起功能障碍的基线参数
背景:勃起功能障碍是指始终无法实现并保持勃起足够的刚性以获得满意的性表现。众所周知,阴茎的血液动力学功能与海绵体动脉(CA)的峰值收缩速度(PSV)密切相关,这是用于评估阴茎勃起组织状态的最可靠、最敏感和最客观的参数。本研究旨在建立这种环境下正常的CA PSV,因为它可能与美国人、高加索人和亚洲人的值不同。材料和方法:该研究于2015年7月至2017年1月在阿布贾联邦医疗中心放射科进行。由泌尿科医生转诊至上述机构放射科进行阴茎超声检查的29名连续患者使用高频线性阵列换能器的三重多普勒超声进行了评估。阴茎扫描在腔内注射10–20μg前列腺素E1前后进行。使用≤60°的倾斜角交替获得CA的波形,并在5分钟至40分钟的间隔内记录CA的PSV。结果:在整个研究参与者中,CA的PSV在26至104.4 cm/s之间变化(平均值:46.72±16.21)。右侧和左侧海绵体动脉的PSV之间没有显著差异。PSV与年龄呈正相关(P=0.002),在≤30岁的人群中最高。结论:本研究中确定的海绵体动脉的平均PSV与美国人、高加索人和亚洲人之间的值没有显著差异,表明种族差异对这一重要的超声变量没有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
West African Journal of Radiology
West African Journal of Radiology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信