Horizontal Vibration Transmission Characteristics of a Magnetic Levitation Type Seismic Isolation Model Device with Stable Levitation System

Y. Nagasaki, Gen Kamada, T. Katana, S. Sasaki, D. Miyagi, M. Tsuda
{"title":"Horizontal Vibration Transmission Characteristics of a Magnetic Levitation Type Seismic Isolation Model Device with Stable Levitation System","authors":"Y. Nagasaki, Gen Kamada, T. Katana, S. Sasaki, D. Miyagi, M. Tsuda","doi":"10.2221/jcsj.55.117","DOIUrl":null,"url":null,"abstract":"Synopsis: This paper discusses the demonstration of a stable levitation (SL) system for a magnetic levitation type seismic isolation device using a high-temperature superconducting (HTS) bulk. The SL system utilizes a restoring force between an HTS bulk and permanent magnet (PM) to maintain the stable levitation of a base-isolation object. We first measured the restoring force between the HTS bulk and PM, and then demonstrated the performance of the SL system using a magnetic levitation type seismic isolation model device with a radial arrangement of HTS bulks and a PM rail. The SL system with the HTS bulk can reduce small vibration and displacement during the normal period of operation without experiencing a large disturbance. We also demonstrated that, when a large disturbance was applied, the transmission of horizontal vibration to the base-isolation object via the SL system was eliminated by decoupling the magnetic coupling between the HTS bulk and PM. Furthermore, the vibration transmissibility at any vibration frequency to the base-isolation object was reduced by incorporating an HTS bulk damper and eddy current damper in the model device. These results suggest that a SL system used together with an HTS bulk can realize both the stable levitation of a base-isolation object during the normal period of operation as well as the elimination of the horizontal vibration transmission when a large vibration is applied.","PeriodicalId":93144,"journal":{"name":"Teion kogaku = Cryogenic engineering : [official journal of the Cryogenic Association of Japan]","volume":"55 1","pages":"117-124"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Teion kogaku = Cryogenic engineering : [official journal of the Cryogenic Association of Japan]","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2221/jcsj.55.117","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Synopsis: This paper discusses the demonstration of a stable levitation (SL) system for a magnetic levitation type seismic isolation device using a high-temperature superconducting (HTS) bulk. The SL system utilizes a restoring force between an HTS bulk and permanent magnet (PM) to maintain the stable levitation of a base-isolation object. We first measured the restoring force between the HTS bulk and PM, and then demonstrated the performance of the SL system using a magnetic levitation type seismic isolation model device with a radial arrangement of HTS bulks and a PM rail. The SL system with the HTS bulk can reduce small vibration and displacement during the normal period of operation without experiencing a large disturbance. We also demonstrated that, when a large disturbance was applied, the transmission of horizontal vibration to the base-isolation object via the SL system was eliminated by decoupling the magnetic coupling between the HTS bulk and PM. Furthermore, the vibration transmissibility at any vibration frequency to the base-isolation object was reduced by incorporating an HTS bulk damper and eddy current damper in the model device. These results suggest that a SL system used together with an HTS bulk can realize both the stable levitation of a base-isolation object during the normal period of operation as well as the elimination of the horizontal vibration transmission when a large vibration is applied.
具有稳定悬浮系统的磁悬浮型隔震模型装置水平振动传递特性
简介:本文讨论了使用高温超导(HTS)块体的磁悬浮式隔震装置的稳定悬浮(SL)系统的演示。SL系统利用HTS块体和永磁体(PM)之间的恢复力来维持基础隔离物体的稳定悬浮。我们首先测量了HTS块体和PM之间的恢复力,然后使用具有HTS块体径向布置和PM轨道的磁悬浮型隔震模型装置演示了SL系统的性能。具有HTS体积的SL系统可以在正常运行期间减少较小的振动和位移,而不会受到较大的干扰。我们还证明,当施加大扰动时,通过解耦HTS本体和PM之间的磁耦合,消除了通过SL系统向基础隔离对象传递的水平振动。此外,通过在模型装置中加入HTS大块阻尼器和涡流阻尼器,降低了在任何振动频率下到基础隔离对象的振动传递性。这些结果表明,与HTS块体一起使用的SL系统既可以在正常运行期间实现基础隔离物体的稳定悬浮,也可以在施加大振动时消除水平振动传递。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信