Sielvya Rahma Maulida, Mia Galina, Joni Welman Simatupang
{"title":"Analisis Intensitas Konsumsi Energi RS Medirossa Cikarang","authors":"Sielvya Rahma Maulida, Mia Galina, Joni Welman Simatupang","doi":"10.33021/JEEE.V2I1.708","DOIUrl":null,"url":null,"abstract":"Medirossa Hospital is one of the health care centers in the city of Cikarang which in its operations does not only focus on the customer excellent services but also pay attention to the comfort of the environment and the completeness of the health facilities. One factor that determines the convenience of a hospital is the intensity of lighting. From the observations made by the authors of several rooms at Medirossa Cikarang Hospital, namely the casemix room, medical records, VIP treatment, and the hall leading to the second floor has less bright lighting. This observation was carried out by surveying 26 respondents who were hospital employees and visitors. From the observation, 53% of respondents stated that the room was \"not bright enough.\" To find out whether the lighting in the room surveyed is actually less than the Indonesian National Standard (SNI 6197: 2011), it is necessary to measure the intensity of lighting using a measuring instrument, calculating and analyzing of IKE (intensity of energy consumption) values, which can then be continued with lighting improvement if the IKE value is below the applicable lighting standard. Based on the results of calculations and analysis it was found that the value of IKE RS Medirossa Cikarang is 248.603 kWh/m² year. This value indicates that electricity consumption is efficient, but has not fulfilled the applicable standards. To achieve the intensity of lighting in the rooms that have been surveyed, it is necessary to add a lamp that resulted in additional load of 748 Watt. This study aims to provide analysis and suggestion to regarding the intensity of energy consumption of RS Medirossa Cikarang for hospital lighting improvements which in turn can improve the comfort of hospital employees and visitors","PeriodicalId":39047,"journal":{"name":"Journal of Electrical and Electronics Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrical and Electronics Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33021/JEEE.V2I1.708","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 1
Abstract
Medirossa Hospital is one of the health care centers in the city of Cikarang which in its operations does not only focus on the customer excellent services but also pay attention to the comfort of the environment and the completeness of the health facilities. One factor that determines the convenience of a hospital is the intensity of lighting. From the observations made by the authors of several rooms at Medirossa Cikarang Hospital, namely the casemix room, medical records, VIP treatment, and the hall leading to the second floor has less bright lighting. This observation was carried out by surveying 26 respondents who were hospital employees and visitors. From the observation, 53% of respondents stated that the room was "not bright enough." To find out whether the lighting in the room surveyed is actually less than the Indonesian National Standard (SNI 6197: 2011), it is necessary to measure the intensity of lighting using a measuring instrument, calculating and analyzing of IKE (intensity of energy consumption) values, which can then be continued with lighting improvement if the IKE value is below the applicable lighting standard. Based on the results of calculations and analysis it was found that the value of IKE RS Medirossa Cikarang is 248.603 kWh/m² year. This value indicates that electricity consumption is efficient, but has not fulfilled the applicable standards. To achieve the intensity of lighting in the rooms that have been surveyed, it is necessary to add a lamp that resulted in additional load of 748 Watt. This study aims to provide analysis and suggestion to regarding the intensity of energy consumption of RS Medirossa Cikarang for hospital lighting improvements which in turn can improve the comfort of hospital employees and visitors
期刊介绍:
Journal of Electrical and Electronics Engineering is a scientific interdisciplinary, application-oriented publication that offer to the researchers and to the PhD students the possibility to disseminate their novel and original scientific and research contributions in the field of electrical and electronics engineering. The articles are reviewed by professionals and the selection of the papers is based only on the quality of their content and following the next criteria: the papers presents the research results of the authors, the papers / the content of the papers have not been submitted or published elsewhere, the paper must be written in English, as well as the fact that the papers should include in the reference list papers already published in recent years in the Journal of Electrical and Electronics Engineering that present similar research results. The topics and instructions for authors of this journal can be found to the appropiate sections.