METROLOGICAL SUPPORT OF PULSE OXIMETERS

E. Tverytnykova, T. Drozdova, Yulianna A. Demidova, N. Kuzmenko
{"title":"METROLOGICAL SUPPORT OF PULSE OXIMETERS","authors":"E. Tverytnykova, T. Drozdova, Yulianna A. Demidova, N. Kuzmenko","doi":"10.20998/2522-9052.2022.1.13","DOIUrl":null,"url":null,"abstract":"The experience of the International Medical Device Regulators Forum in the use of products for oxygen therapy based on the study of guidelines, international and European regulations on medical devices is considered. Emphasis is placed on issues related to the metrological support of pulse oximeters. The global situation with the pandemic increases the relevance of selected topics. Continuous monitoring of blood oxygen saturation is one of the most important elements in the diagnosis and treatment of COVID-19. Despite the fact that the use of pulse oximeters does not require special medical knowledge, calibration and special maintenance, it is still necessary to control their reliability and accuracy of measurement. The study of pulse oximeter MD300M in accordance with the requirements of DSTU 8893:2019 \"Metrology. Pulse oximeters. Calibration Method” 2020. Analysis of MD300M pulse oximeter calibration results revealed that this pulse oximeter was calibrated by the saturation and pulse measurement channel, as the maximum deviation of the measured saturation value from the pulse oximeter calibration measure does not exceed the pulse oximeter measurement documentation specified in the operating documentation. The discreteness of the MD300M pulse oximeter and the discreteness of the reference device MPPO-2, which are specified in the passports for the respective devices, have the greatest influence on the measurement uncertainty.","PeriodicalId":34701,"journal":{"name":"Suchasni informatsiini sistemi","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Suchasni informatsiini sistemi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20998/2522-9052.2022.1.13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The experience of the International Medical Device Regulators Forum in the use of products for oxygen therapy based on the study of guidelines, international and European regulations on medical devices is considered. Emphasis is placed on issues related to the metrological support of pulse oximeters. The global situation with the pandemic increases the relevance of selected topics. Continuous monitoring of blood oxygen saturation is one of the most important elements in the diagnosis and treatment of COVID-19. Despite the fact that the use of pulse oximeters does not require special medical knowledge, calibration and special maintenance, it is still necessary to control their reliability and accuracy of measurement. The study of pulse oximeter MD300M in accordance with the requirements of DSTU 8893:2019 "Metrology. Pulse oximeters. Calibration Method” 2020. Analysis of MD300M pulse oximeter calibration results revealed that this pulse oximeter was calibrated by the saturation and pulse measurement channel, as the maximum deviation of the measured saturation value from the pulse oximeter calibration measure does not exceed the pulse oximeter measurement documentation specified in the operating documentation. The discreteness of the MD300M pulse oximeter and the discreteness of the reference device MPPO-2, which are specified in the passports for the respective devices, have the greatest influence on the measurement uncertainty.
脉搏血氧计的计量支持
审议了国际医疗器械监管机构论坛在研究医疗器械准则、国际和欧洲法规的基础上,在氧气治疗产品使用方面的经验。重点放在与脉搏血氧计的计量支持有关的问题上。这一流行病的全球形势增加了选定专题的相关性。持续监测血氧饱和度是COVID-19诊断和治疗的重要内容之一。尽管脉搏血氧仪的使用不需要特殊的医学知识、校准和特殊的维护,但仍然需要控制其测量的可靠性和准确性。脉搏血氧仪MD300M的研究符合DSTU 8893:2019“计量学”的要求。脉搏血氧仪。《校准方法》2020。对MD300M脉搏血氧仪校准结果的分析表明,该脉搏血氧仪是通过饱和度和脉搏测量通道校准的,因为测量的饱和度值与脉搏血氧仪校准测量值的最大偏差不超过操作文档中规定的脉搏血氧仪测量文档。MD300M脉搏血氧仪的离散性和参考设备MPPO-2的离散性在各自设备的护照中规定,对测量不确定度的影响最大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
47
审稿时长
5 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书