Simple Self-calibrating Polarimeter forMeasuring the Stokes Parameters of Light

IF 1.6 Q3 OPTICS
OSA Continuum Pub Date : 2021-05-26 DOI:10.1364/OSAC.444102
Vitaly Wirthl, C. Panda, P. Hess, G. Gabrielse
{"title":"Simple Self-calibrating Polarimeter forMeasuring the Stokes Parameters of Light","authors":"Vitaly Wirthl, C. Panda, P. Hess, G. Gabrielse","doi":"10.1364/OSAC.444102","DOIUrl":null,"url":null,"abstract":"A simple, self-calibrating, rotating-waveplate polarimeter is largely insensitive to light intensity fluctuations and is shown to be useful for determining the Stokes parameters of light. This study shows how to minimize the in situ self-calibration time, the measurement time and the measurement uncertainty. The suggested methods are applied to measurements of spatial variations in the linear and circular polarizations of laser light passing through glass plates with a laser intensity dependent birefringence. These are crucial measurements for the ACME electron electric dipole measurements, requiring accuracies in circular and linear polarization fraction of about 0.1% and 0.4%, with laser intensities up to 100 $\\text{mW/mm}^2$ incident into the polarimeter.","PeriodicalId":19750,"journal":{"name":"OSA Continuum","volume":" ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2021-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"OSA Continuum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/OSAC.444102","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0

Abstract

A simple, self-calibrating, rotating-waveplate polarimeter is largely insensitive to light intensity fluctuations and is shown to be useful for determining the Stokes parameters of light. This study shows how to minimize the in situ self-calibration time, the measurement time and the measurement uncertainty. The suggested methods are applied to measurements of spatial variations in the linear and circular polarizations of laser light passing through glass plates with a laser intensity dependent birefringence. These are crucial measurements for the ACME electron electric dipole measurements, requiring accuracies in circular and linear polarization fraction of about 0.1% and 0.4%, with laser intensities up to 100 $\text{mW/mm}^2$ incident into the polarimeter.
测量光斯托克斯参数的简易自校准偏振仪
一种简单的自校准旋转波片偏振仪在很大程度上对光强波动不敏感,并被证明可用于确定光的斯托克斯参数。该研究展示了如何最大限度地减少原位自校准时间、测量时间和测量不确定度。所提出的方法被应用于测量激光穿过具有激光强度相关双折射的玻璃板的线性和圆形偏振的空间变化。这些是ACME电子-电偶极子测量的关键测量,要求圆偏振和线偏振部分的精度分别为0.1%和0.4%,激光强度高达100$\text{mW/mm}^2$入射到偏振仪中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
OSA Continuum
OSA Continuum OPTICS-
自引率
0.00%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信