Use of polyethylene consumables in neutron activation analysis for short-lived radionuclides

IF 0.3 Q4 CHEMISTRY, MULTIDISCIPLINARY
K. Bedelbekova, S. Lennik, Yevgeniy Sokolenko, T. Suzdaltseva
{"title":"Use of polyethylene consumables in neutron activation analysis for short-lived radionuclides","authors":"K. Bedelbekova, S. Lennik, Yevgeniy Sokolenko, T. Suzdaltseva","doi":"10.15328/cb1318","DOIUrl":null,"url":null,"abstract":"The neutron activation analysis for short-lived radionuclides at the WWR-K uses a pneumatic transport system (Austria) with specific transport capsules. The irradiated samples are not removed from the transport capsules and are measured directly in the capsule. It is necessary to take into account the fact that the induced activity of the capsule material itself acts as the background radiation in relation to the induced activity of the sample under study.\n\nA study of the capsule material and the polyethylene tubes used as sample fixing devices in the center of the transport capsule was performed. Earlier it was found that the HDPE T50 capsule material contains impurity elements Ti, Cl, Al, Na, Ca. It was found that the fixing material contains a larger amount of impurities, which leads to the increase of spectrometric equipment loading and to the increase of relative contribution of individual radionuclides to the final spectrum. The induced activity spectra were analyzed and processed, the content of elements in polyethylene was calculated and it was shown that the analytical signals of Mg-27, Mn-56 and Sb-122m, Cr-51 and Sb-122 refer exclusively to the induced activity of the fixer-tube material. This circumstance does not allow to determine small concentrations of these elements in the samples themselves. The necessity of search of other more pure material for its use as sample fixers at placement in a transport capsule is shown.","PeriodicalId":9860,"journal":{"name":"Chemical Bulletin of Kazakh National University","volume":" ","pages":""},"PeriodicalIF":0.3000,"publicationDate":"2023-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemical Bulletin of Kazakh National University","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15328/cb1318","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

The neutron activation analysis for short-lived radionuclides at the WWR-K uses a pneumatic transport system (Austria) with specific transport capsules. The irradiated samples are not removed from the transport capsules and are measured directly in the capsule. It is necessary to take into account the fact that the induced activity of the capsule material itself acts as the background radiation in relation to the induced activity of the sample under study. A study of the capsule material and the polyethylene tubes used as sample fixing devices in the center of the transport capsule was performed. Earlier it was found that the HDPE T50 capsule material contains impurity elements Ti, Cl, Al, Na, Ca. It was found that the fixing material contains a larger amount of impurities, which leads to the increase of spectrometric equipment loading and to the increase of relative contribution of individual radionuclides to the final spectrum. The induced activity spectra were analyzed and processed, the content of elements in polyethylene was calculated and it was shown that the analytical signals of Mg-27, Mn-56 and Sb-122m, Cr-51 and Sb-122 refer exclusively to the induced activity of the fixer-tube material. This circumstance does not allow to determine small concentrations of these elements in the samples themselves. The necessity of search of other more pure material for its use as sample fixers at placement in a transport capsule is shown.
聚乙烯耗材在短寿命放射性核素中子活化分析中的应用
WWR-K对短寿命放射性核素的中子活化分析使用带有特定传输胶囊的气动传输系统(奥地利)。辐照后的样品不从运输胶囊中取出,直接在胶囊中测量。有必要考虑到这样一个事实,即胶囊材料本身的诱导活性作为与所研究样品的诱导活性相关的背景辐射。对胶囊材料和作为样品固定装置的聚乙烯管在运输胶囊中心进行了研究。前期发现HDPE T50胶囊材料中含有杂质元素Ti、Cl、Al、Na、Ca,固定材料中杂质含量较大,导致光谱设备负荷增加,单个放射性核素对最终光谱的相对贡献增大。对诱导活度谱进行了分析和处理,计算了聚乙烯中元素的含量,结果表明,Mg-27、Mn-56和Sb-122m、Cr-51和Sb-122的分析信号完全是指固定管材料的诱导活度。这种情况不允许测定样品本身中这些元素的小浓度。必须寻找其他更纯净的材料作为放置在运输胶囊中的样品固定剂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
17
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信