Analysis of Ethyl p-Methoxycinnamate from Kaempferia galanga L. Extract by High Performance Liquid Chromatography

W. Winingsih, Sri Gustini Husein, Rozalia Putri Neno Ramdhani
{"title":"Analysis of Ethyl p-Methoxycinnamate from Kaempferia galanga L. Extract by High Performance Liquid Chromatography","authors":"W. Winingsih, Sri Gustini Husein, Rozalia Putri Neno Ramdhani","doi":"10.25026/jtpc.v5i4.331","DOIUrl":null,"url":null,"abstract":"Ethyl para-methoxycinamate (EPMS) is a major compound of Kaempferia galanga L that has anti-inflammatory effect.  The purpose of this study was to determine of EPMS in Kaempferiae galanga L rhizome extract by  High Performance Liquid Chromatography (HPLC) and evaluated the performance of the analysis. This study included determination of system suitability, accuracy, precision, linearity and range, limit of detection (LOD) and Limit of quantitation (LOQ) and selectivity.  The results of system suitability test  HPLC System for EPMS analysis were as follows isocratic elution system of a mobile phase mixture of methanol: water (70:30) containing 0.1% TFA, uv detector at a wavelength of 308 nm using column C18 (150 × 4, 6mm, 5μm) flow rate 1 ml / min. From the analysis, it was found that the average EPMS content was 78.74%. Then method had linear concentration range from 5-360 ppm, with R ² = 0.9999. The LOD and LOQ were 7.0722 ppm and 21.4311 ppm respectively. The accuracy of this method that represented by % recovery was 98.02% - 101.26%. The precision of this method that expressed by Relative Standard Deviation (RSD) was 1.57%. The selectivity of this method that showed by  resolution value was 2.6. Based on the results of the system suitability test and analysis performance evaluation,all parameters met the requirements.","PeriodicalId":17494,"journal":{"name":"Journal of Tropical Pharmacy and Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Tropical Pharmacy and Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25026/jtpc.v5i4.331","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Ethyl para-methoxycinamate (EPMS) is a major compound of Kaempferia galanga L that has anti-inflammatory effect.  The purpose of this study was to determine of EPMS in Kaempferiae galanga L rhizome extract by  High Performance Liquid Chromatography (HPLC) and evaluated the performance of the analysis. This study included determination of system suitability, accuracy, precision, linearity and range, limit of detection (LOD) and Limit of quantitation (LOQ) and selectivity.  The results of system suitability test  HPLC System for EPMS analysis were as follows isocratic elution system of a mobile phase mixture of methanol: water (70:30) containing 0.1% TFA, uv detector at a wavelength of 308 nm using column C18 (150 × 4, 6mm, 5μm) flow rate 1 ml / min. From the analysis, it was found that the average EPMS content was 78.74%. Then method had linear concentration range from 5-360 ppm, with R ² = 0.9999. The LOD and LOQ were 7.0722 ppm and 21.4311 ppm respectively. The accuracy of this method that represented by % recovery was 98.02% - 101.26%. The precision of this method that expressed by Relative Standard Deviation (RSD) was 1.57%. The selectivity of this method that showed by  resolution value was 2.6. Based on the results of the system suitability test and analysis performance evaluation,all parameters met the requirements.
山奈提取物中对甲氧基肉桂酸乙酯的高效液相色谱分析
对甲氧基肉桂酸乙酯(EPMS)是山奈的主要化合物,具有抗炎作用。采用高效液相色谱法(HPLC)测定山柰根提取物中EPMS的含量,并对其分析性能进行评价。本研究包括系统适用性、准确度、精密度、线性和范围、检测限(LOD)、定量限(LOQ)和选择性的测定。系统适用性测试HPLC系统用于EPMS分析的结果如下:甲醇:水(70:30)的流动相混合物(含0.1%TFA)的等度洗脱系统,使用C18柱(150×4,6mm,5μm)流速1ml/min在波长308nm的紫外检测器,结果表明,EPMS的平均含量为78.74%。该方法的线性浓度范围为5-360ppm,R²=0.999。LOD和LOQ分别为7.0722ppm和21.4311ppm。以回收率%表示的准确度为98.02%-101.26%,以相对标准偏差(RSD)表示的精密度为1.57%,以分离度值表示的选择性为2.6。根据系统适用性测试和分析性能评估的结果,所有参数均符合要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
12
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信