VALIDATION OF THE METHODS OF Hg DETERMINATION ON WASTE WATER TREATMENT PLANT SAMPLES USING COLD VAPOUR-ATOMIC ABSORPTION SPECTROPHOTOMETER (CV-AAS)TECHNIQUES

Rika Anggraini, R. Hairani, A. S. Panggabean
{"title":"VALIDATION OF THE METHODS OF Hg DETERMINATION ON WASTE WATER TREATMENT PLANT SAMPLES USING COLD VAPOUR-ATOMIC ABSORPTION SPECTROPHOTOMETER (CV-AAS)TECHNIQUES","authors":"Rika Anggraini, R. Hairani, A. S. Panggabean","doi":"10.30872/JKM.V16I1.667","DOIUrl":null,"url":null,"abstract":"The research about validation of the method of Hg determination on the sample from wastewater treatment plant (WWTP) PT. Badak NGL Bontang, Kalimantan Timur using cold vapour-atomic absorption spectrophotometer (CV-AAS) techniques has been conducted. To obtain a valid measurement result, determinations of the important several parameters that influence the method validation are used. The results of research showed that 20% SnCl2 solution could be used as a reducing agent. The analytic performance of measurement obtain is good, showed with the linearity (r) value ≥ 0.995, LOD was 0.2530 ppb, LOQ was 0.8432 ppb, MDL was 0.6427 ppb and repeatability and reproducibility are shown as % RSD < 2/3 CV Horwitz values. The accuracy of this method is very good with a percentage of recovery value of 114.88%. Based on the results of this research, CV-AAS method can be used in the determination of Hg in WWTP samples with the valid results.","PeriodicalId":31725,"journal":{"name":"Jurnal Kimia Mulawarman","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Kimia Mulawarman","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30872/JKM.V16I1.667","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The research about validation of the method of Hg determination on the sample from wastewater treatment plant (WWTP) PT. Badak NGL Bontang, Kalimantan Timur using cold vapour-atomic absorption spectrophotometer (CV-AAS) techniques has been conducted. To obtain a valid measurement result, determinations of the important several parameters that influence the method validation are used. The results of research showed that 20% SnCl2 solution could be used as a reducing agent. The analytic performance of measurement obtain is good, showed with the linearity (r) value ≥ 0.995, LOD was 0.2530 ppb, LOQ was 0.8432 ppb, MDL was 0.6427 ppb and repeatability and reproducibility are shown as % RSD < 2/3 CV Horwitz values. The accuracy of this method is very good with a percentage of recovery value of 114.88%. Based on the results of this research, CV-AAS method can be used in the determination of Hg in WWTP samples with the valid results.
用冷蒸汽原子吸收分光光度计(CV-AAS)测定污水处理厂样品中汞的方法的验证
采用冷蒸气原子吸收分光光度计(CV-AAS)技术对加里曼丹-帖木尔省巴达克NGL邦唐污水处理厂(WWTP)样品中汞的测定方法进行了验证研究。为了获得有效的测量结果,需要确定影响方法验证的几个重要参数。研究结果表明,20%SnCl2溶液可以作为还原剂使用。测定结果的分析性能良好,线性(r)值≥0.995,检出限为0.2530ppb,定量限为0.8432ppb,MDL为0.6427ppb,重复性和再现性以%RSD<2/3 CV-Horwitz值表示。该方法准确度高,回收率为114.88%,可用于污水处理厂样品中汞的测定,结果有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
3
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信