Does the intra-operatively measured leg length correction compare to the post-operative radiograph in total hip replacement surgery?

Q4 Medicine
Z. Moonda, M. Nortje, R. Dey
{"title":"Does the intra-operatively measured leg length correction compare to the post-operative radiograph in total hip replacement surgery?","authors":"Z. Moonda, M. Nortje, R. Dey","doi":"10.17159/2309-8309/2020/V19N4A2","DOIUrl":null,"url":null,"abstract":"Background: This study aims to analyse the accuracy of the Vertical Measurement System™ (VMS) in assessing the leg length correction (LLC) during total hip arthroplasty (THA) by comparing the intra-operative measurements to the radiographic measurements obtained six weeks post-operatively. \nPatients and methods: A prospective cohort study was conducted in which patients undergoing primary THA were enrolled at two centres in Cape Town, over a period of 19 weeks. THAs were performed by four surgeons. Pre-operative leg length discrepancy (LLD) measurements were obtained in 92 patients. The VMS was used to predict intra-operative LLC, and this measurement was compared to the post-operative LLC measured on the six-week follow-up X-ray. These measurements were statistically compared using the Mann–Whitney U test. \nResults: The difference between the intra-operative VMS calculation and the six-week radiological measurement was not significant (p>0.05), with the difference in their mean values being 0.1±3.3 mm. In the cohort, 82% of the patients (n=75) were within 5 mm of the target LLC, and 96% of patients (n=88) were within 10 mm of the target LLC. The mean absolute residual LLD at six weeks was 3.2±3.1 mm. \nConclusion: The intra-operative LLC measurement obtained using the VMS accurately predicts the six-week post-operative radiographic LLC measurement. \nLevel of evidence: Level 4","PeriodicalId":32220,"journal":{"name":"SA Orthopaedic Journal","volume":"19 1","pages":"206-211"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SA Orthopaedic Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17159/2309-8309/2020/V19N4A2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: This study aims to analyse the accuracy of the Vertical Measurement System™ (VMS) in assessing the leg length correction (LLC) during total hip arthroplasty (THA) by comparing the intra-operative measurements to the radiographic measurements obtained six weeks post-operatively. Patients and methods: A prospective cohort study was conducted in which patients undergoing primary THA were enrolled at two centres in Cape Town, over a period of 19 weeks. THAs were performed by four surgeons. Pre-operative leg length discrepancy (LLD) measurements were obtained in 92 patients. The VMS was used to predict intra-operative LLC, and this measurement was compared to the post-operative LLC measured on the six-week follow-up X-ray. These measurements were statistically compared using the Mann–Whitney U test. Results: The difference between the intra-operative VMS calculation and the six-week radiological measurement was not significant (p>0.05), with the difference in their mean values being 0.1±3.3 mm. In the cohort, 82% of the patients (n=75) were within 5 mm of the target LLC, and 96% of patients (n=88) were within 10 mm of the target LLC. The mean absolute residual LLD at six weeks was 3.2±3.1 mm. Conclusion: The intra-operative LLC measurement obtained using the VMS accurately predicts the six-week post-operative radiographic LLC measurement. Level of evidence: Level 4
在全髋关节置换术中,术中测量的腿长矫正是否与术后x线片比较?
背景:本研究旨在通过比较术中测量值与术后6周的x线测量值,分析垂直测量系统(VMS)在评估全髋关节置换术(THA)期间腿长矫正(LLC)的准确性。患者和方法:进行了一项前瞻性队列研究,在开普敦的两个中心招募了接受原发性THA的患者,为期19周。手术由四位外科医生完成。对92例患者进行术前腿长差异(LLD)测量。VMS用于预测术中LLC,并将该测量值与术后6周随访x线测量值进行比较。使用Mann-Whitney U检验对这些测量值进行统计比较。结果:术中VMS计算值与6周放射测量值差异无统计学意义(p < 0.05),其平均值差异为0.1±3.3 mm。在队列中,82%的患者(n=75)在目标LLC的5 mm范围内,96%的患者(n=88)在目标LLC的10 mm范围内。6周时平均绝对剩余LLD为3.2±3.1 mm。结论:VMS术中LLC测量准确预测了术后6周的x线LLC测量。证据等级:四级
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
SA Orthopaedic Journal
SA Orthopaedic Journal Medicine-Orthopedics and Sports Medicine
CiteScore
0.40
自引率
0.00%
发文量
17
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信