Anterior Segment Changes and Refractive Outcomes after Cataract Surgery Combined with Gonioscopy-Assisted Transluminal Trabeculotomy in Open-Angle Glaucoma
Hatice Tekcan, Serhat İmamoğlu, Mehmet Serhat Mangan
{"title":"Anterior Segment Changes and Refractive Outcomes after Cataract Surgery Combined with Gonioscopy-Assisted Transluminal Trabeculotomy in Open-Angle Glaucoma","authors":"Hatice Tekcan, Serhat İmamoğlu, Mehmet Serhat Mangan","doi":"10.4274/tjo.galenos.2023.36080","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To compare the accuracy of intraocular lens (IOL) calculation formulas in patients undergoing phacoemulsification combined with gonioscopy-assisted transluminal trabeculotomy (phaco-GATT) and to determine the predictive factors for refractive errors.</p><p><strong>Materials and methods: </strong>Fifty-three eyes of 53 patients undergoing phaco-GATT were retrospectively reviewed. The preoperative and postoperative 3-month anterior segment (AS) parameters were measured by Scheimpflug camera. The mean prediction error (PE), mean absolute error (MAE) in the Sanders-Retzlaff-Kraft/theoretical (SRK/T), Barrett- Universal II, Hill-radial basis function (Hill-RBF) and Kane formulas were compared. The influence of biometric parameters on PE were analyzed by correlation analysis.</p><p><strong>Results: </strong>Postoperatively, there was a statistically significant decrease in axial length (AL) and significant enlargement in anterior chamber depth (ACD), anterior chamber angle (ACA), and anterior chamber volume (p<0.001). The mean PE using SRK/T (-0.08 diopters [D]) was more myopic than in the Barret (0.01 D) and Hill-RBF (0.01 D). The PE closest to zero was in the Kane formula (0.001 D). The Kane formula provided a lower MAE (0.30±0.28 D) than the SRK/T (0.38±0.32 D) and Barrett (0.36±0.30 D) (p<0.001). The MAE in Hill-RBF (0.32±0.28) was comparable with that in Kane (p=0.02). Preoperative AL was significantly associated with PE in all formulas except Kane. Barrett was the only formula that did not have a significant correlation between PE and postoperative ACD and ACA.</p><p><strong>Conclusion: </strong>The Kane formula may provide higher predictability of the IOL power calculation than the SRK/T and Barrett-Universal II formulas in phaco-GATT surgery, which can cause significant changes in the AS and AL.</p>","PeriodicalId":23373,"journal":{"name":"Turkish Journal of Ophthalmology","volume":" ","pages":"369-376"},"PeriodicalIF":0.0000,"publicationDate":"2023-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10750090/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4274/tjo.galenos.2023.36080","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/4 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: To compare the accuracy of intraocular lens (IOL) calculation formulas in patients undergoing phacoemulsification combined with gonioscopy-assisted transluminal trabeculotomy (phaco-GATT) and to determine the predictive factors for refractive errors.
Materials and methods: Fifty-three eyes of 53 patients undergoing phaco-GATT were retrospectively reviewed. The preoperative and postoperative 3-month anterior segment (AS) parameters were measured by Scheimpflug camera. The mean prediction error (PE), mean absolute error (MAE) in the Sanders-Retzlaff-Kraft/theoretical (SRK/T), Barrett- Universal II, Hill-radial basis function (Hill-RBF) and Kane formulas were compared. The influence of biometric parameters on PE were analyzed by correlation analysis.
Results: Postoperatively, there was a statistically significant decrease in axial length (AL) and significant enlargement in anterior chamber depth (ACD), anterior chamber angle (ACA), and anterior chamber volume (p<0.001). The mean PE using SRK/T (-0.08 diopters [D]) was more myopic than in the Barret (0.01 D) and Hill-RBF (0.01 D). The PE closest to zero was in the Kane formula (0.001 D). The Kane formula provided a lower MAE (0.30±0.28 D) than the SRK/T (0.38±0.32 D) and Barrett (0.36±0.30 D) (p<0.001). The MAE in Hill-RBF (0.32±0.28) was comparable with that in Kane (p=0.02). Preoperative AL was significantly associated with PE in all formulas except Kane. Barrett was the only formula that did not have a significant correlation between PE and postoperative ACD and ACA.
Conclusion: The Kane formula may provide higher predictability of the IOL power calculation than the SRK/T and Barrett-Universal II formulas in phaco-GATT surgery, which can cause significant changes in the AS and AL.
期刊介绍:
The Turkish Journal of Ophthalmology (TJO) is the only scientific periodical publication of the Turkish Ophthalmological Association and has been published since January 1929. In its early years, the journal was published in Turkish and French. Although there were temporary interruptions in the publication of the journal due to various challenges, the Turkish Journal of Ophthalmology has been published continually from 1971 to the present. The target audience includes specialists and physicians in training in ophthalmology in all relevant disciplines.