{"title":"Optimal design analysis of substation ground grid mesh","authors":"A. Akhikpemelo","doi":"10.4314/njt.v42i2.16","DOIUrl":null,"url":null,"abstract":"Substations are grounded by means of earth-embedded electrodes in order to provide safety during normal or fault conditions. Electric substations are effectively grounded to guarantee the proper operation of electrical devices, minimize the likelihood of flash-over during transient conditions as well as dispel lightning strokes. A structure is termed grounded if it is electrically bonded to earth-embedded metallic frames. The earth-embedded metallic frames provide a conducting pathway of electricity to the earth and it is called a ground grid system. Substation ground grid mesh is comprised of vertical and horizontal conductors as well as vertical rods buried beneath the substation ground. Electric current flow through the human body is hazardous. Therefore, ground grid systems should be designed such that the likely electric body current in an operator or passer-by should not exceed the standard defined limits under any foreseeable harmful circumstances and as well provide protection of equipment. The objective of this study is to determine substation, safe ground grid system parameters as well as the cost-effectiveness of designing substation ground grids by comparing the IEEE Std. 80-2000/2013 and the Finite Element Method (FEM). ETAP 16.0 Power Tool is employed in carrying out this analysis. The substation expected maximum short circuit current is stated. The design analysis using both methods is presented separately and suggestions are made with reference to the most cost effective and safest method for the effective designing of the substation ground grid system.","PeriodicalId":33360,"journal":{"name":"Nigerian Journal of Technology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nigerian Journal of Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4314/njt.v42i2.16","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Substations are grounded by means of earth-embedded electrodes in order to provide safety during normal or fault conditions. Electric substations are effectively grounded to guarantee the proper operation of electrical devices, minimize the likelihood of flash-over during transient conditions as well as dispel lightning strokes. A structure is termed grounded if it is electrically bonded to earth-embedded metallic frames. The earth-embedded metallic frames provide a conducting pathway of electricity to the earth and it is called a ground grid system. Substation ground grid mesh is comprised of vertical and horizontal conductors as well as vertical rods buried beneath the substation ground. Electric current flow through the human body is hazardous. Therefore, ground grid systems should be designed such that the likely electric body current in an operator or passer-by should not exceed the standard defined limits under any foreseeable harmful circumstances and as well provide protection of equipment. The objective of this study is to determine substation, safe ground grid system parameters as well as the cost-effectiveness of designing substation ground grids by comparing the IEEE Std. 80-2000/2013 and the Finite Element Method (FEM). ETAP 16.0 Power Tool is employed in carrying out this analysis. The substation expected maximum short circuit current is stated. The design analysis using both methods is presented separately and suggestions are made with reference to the most cost effective and safest method for the effective designing of the substation ground grid system.
变电站地网网优化设计分析
变电站通过埋地电极接地,以便在正常或故障情况下提供安全。变电站有效接地,保证电气设备的正常运行,最大限度地减少暂态条件下闪络的可能性,并消除雷击。如果结构与接地金属框架电连接,则称为接地结构。埋入地下的金属框架为大地提供了导电通道,称为地网系统。变电站地网由垂直导线和水平导线以及埋在变电站地下的垂直杆组成。通过人体的电流是危险的。因此,地网系统的设计应使操作人员或过路人员在任何可预见的有害情况下可能的电流不应超过标准规定的限制,并为设备提供保护。本研究的目的是通过比较IEEE标准80-2000/2013和有限元法(FEM)来确定变电站、安全地网系统参数以及设计变电站地网的成本效益。采用ETAP 16.0电动工具进行分析。给出了变电站的期望最大短路电流。分别对这两种方法进行了设计分析,并对变电站地网系统的有效设计提出了最经济、最安全的建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
126
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信