Factors Associated with the Peak Flow Variation Generated during Forced Manual Hyperinflation Technique

da Silva Luan Rodrigues, Arantes Ana Paula Felix, Cruvinel Fernando Guimarães, da Silva Renato Canevari Dutra
{"title":"Factors Associated with the Peak Flow Variation Generated during Forced Manual Hyperinflation Technique","authors":"da Silva Luan Rodrigues, Arantes Ana Paula Felix, Cruvinel Fernando Guimarães, da Silva Renato Canevari Dutra","doi":"10.23937/2378-3516/1410186","DOIUrl":null,"url":null,"abstract":"Background: Manual hyperinflation is one of the most used respiratory physiotherapy techniques in critically ill patients and consists of administering a higher volume of gaseous fluid than the patient performed using a self-inflating balloon (AMBU). This technique was developed with the objective of removing bronchial secretion and re-expansion of atelectasis lung areas, thus improving pulmonary compliance and oxygenation in mechanically ventilated patients. Objectives: To demonstrate the peak flow variation generated during the physiotherapeutic technique of abrupt manual hyperinflation in an experimental model according to gender and classification among physiotherapists and physicists. Methods: The analytical and exploratory study included 115 participants, who were instructed to carry out the technique of abrupt manual hyperinflation with the AMBU connected to the device of measuring the peak of three times. Data were analyzed descriptively, according to gender and educational level, Shapiro-Wilk test, t-test and Pearson’s correlation coefficient between the mean PEF, height and age variables. Results: The sample consisted of women (74%) and physiotherapists (75%), with a mean of 22.71 ± 5.75 years of age, 116.74 ± 8.36 cm of height and 322.03 + 45.78 l/min peak flow. There was a significant difference between the genders for mean PEF (P = 0.000), for age (P = 0.002) and for height (P = 0.000) and between the average PEF (P = 0.001) and for the age (P = 0.000). Conclusions: Factors such as male gender, educational level and age were positively influenced by the mean peak expiratory flow generated by the manual hyperinflation technique.","PeriodicalId":91516,"journal":{"name":"International journal of respiratory and pulmonary medicine","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of respiratory and pulmonary medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23937/2378-3516/1410186","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Manual hyperinflation is one of the most used respiratory physiotherapy techniques in critically ill patients and consists of administering a higher volume of gaseous fluid than the patient performed using a self-inflating balloon (AMBU). This technique was developed with the objective of removing bronchial secretion and re-expansion of atelectasis lung areas, thus improving pulmonary compliance and oxygenation in mechanically ventilated patients. Objectives: To demonstrate the peak flow variation generated during the physiotherapeutic technique of abrupt manual hyperinflation in an experimental model according to gender and classification among physiotherapists and physicists. Methods: The analytical and exploratory study included 115 participants, who were instructed to carry out the technique of abrupt manual hyperinflation with the AMBU connected to the device of measuring the peak of three times. Data were analyzed descriptively, according to gender and educational level, Shapiro-Wilk test, t-test and Pearson’s correlation coefficient between the mean PEF, height and age variables. Results: The sample consisted of women (74%) and physiotherapists (75%), with a mean of 22.71 ± 5.75 years of age, 116.74 ± 8.36 cm of height and 322.03 + 45.78 l/min peak flow. There was a significant difference between the genders for mean PEF (P = 0.000), for age (P = 0.002) and for height (P = 0.000) and between the average PEF (P = 0.001) and for the age (P = 0.000). Conclusions: Factors such as male gender, educational level and age were positively influenced by the mean peak expiratory flow generated by the manual hyperinflation technique.
强制手动超充气技术中产生峰值流量变化的相关因素
背景:手动过度充气是危重患者最常用的呼吸物理治疗技术之一,与使用自充气气球(AMBU)的患者相比,它包括给药更大体积的气态液体。开发这项技术的目的是去除支气管分泌物并重新扩张肺不张区域,从而改善机械通气患者的肺顺应性和氧合。目的:在一个实验模型中,根据物理治疗师和物理学家的性别和分类,证明在手动突然过度充气的物理治疗技术过程中产生的峰值流量变化。方法:这项分析性和探索性研究包括115名参与者,他们被要求使用连接到三次峰值测量装置的AMBU进行突然手动过度充气技术。根据性别和教育水平、Shapiro-Wilk检验、t检验和平均PEF、身高和年龄变量之间的Pearson相关系数对数据进行描述性分析。结果:样本由女性(74%)和理疗师(75%)组成,平均年龄22.71±5.75岁,身高116.74±8.36厘米,峰值流量322.03±45.78升/分钟。平均PEF(P=0.000)、年龄(P=0.002)和身高(P=0.000。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书