{"title":"The effect of basic cycle length stimuli on effective refractory period measurement","authors":"Mohammd Sadr-Ameli, Farzad Kamali, Milad Vahedinezhad, Sadaf Sadrameli","doi":"10.4103/rcm.rcm_1_21","DOIUrl":null,"url":null,"abstract":"Background: Refractory periods are measured by the extrastimulus technique, whereby a single extrastimulus is introduced at progressively shorter coupling intervals until a response is no longer elicited. Purpose: As refractoriness of cardiac tissues depends on prior cycle length, refractory periods should be determined at a fixed cycle length within the physiologic range. The extrastimulus is delivered after a train of 8 to 10 paced complexes to allow time for reasonable stabilization of refractoriness, which is usually accomplished after the first 3 or 4 paced beats. Objectives: We conducted this study to compare the effect of 6 vs 8 stimuli in basic cycle length (BCL) in measurement of effective refractory period (ERP). Materials and Methods: During electrophysiologic study (EPS) of 100 consecutive patients, anterograde and retrograde ERP of atrioventricular node (AVN) were measured by introduction of 6 vs 8 stimuli in BCL and premature beat, then the results were compared. Results: Recorded anterograde and retrograde ERP of AVN applying 6 vs 8 stimuli in BCL were compared and no difference was detected. Conclusion: We concluded that for ERP measurement of AVN, 6 stimuli in BCL is comparable to 8 stimuli in reaching the steady state.","PeriodicalId":21031,"journal":{"name":"Research in Cardiovascular Medicine","volume":"10 1","pages":"37 - 39"},"PeriodicalIF":0.2000,"publicationDate":"2021-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research in Cardiovascular Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/rcm.rcm_1_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Refractory periods are measured by the extrastimulus technique, whereby a single extrastimulus is introduced at progressively shorter coupling intervals until a response is no longer elicited. Purpose: As refractoriness of cardiac tissues depends on prior cycle length, refractory periods should be determined at a fixed cycle length within the physiologic range. The extrastimulus is delivered after a train of 8 to 10 paced complexes to allow time for reasonable stabilization of refractoriness, which is usually accomplished after the first 3 or 4 paced beats. Objectives: We conducted this study to compare the effect of 6 vs 8 stimuli in basic cycle length (BCL) in measurement of effective refractory period (ERP). Materials and Methods: During electrophysiologic study (EPS) of 100 consecutive patients, anterograde and retrograde ERP of atrioventricular node (AVN) were measured by introduction of 6 vs 8 stimuli in BCL and premature beat, then the results were compared. Results: Recorded anterograde and retrograde ERP of AVN applying 6 vs 8 stimuli in BCL were compared and no difference was detected. Conclusion: We concluded that for ERP measurement of AVN, 6 stimuli in BCL is comparable to 8 stimuli in reaching the steady state.