Experimental Study of a House-Hold Dual Evaporation Temperatures Based Chiller

IF 1.3 4区 工程技术 Q3 ENGINEERING, MECHANICAL
Z. Li, L. Zhang, C. H. Liu, J. B. Chen, M. L. Qu
{"title":"Experimental Study of a House-Hold Dual Evaporation Temperatures Based Chiller","authors":"Z. Li,&nbsp;L. Zhang,&nbsp;C. H. Liu,&nbsp;J. B. Chen,&nbsp;M. L. Qu","doi":"10.1134/S181023282302011X","DOIUrl":null,"url":null,"abstract":"<p>Indoor environment control strategies in small buildings are simply considered, such as achieving the indoor temperature control through ON/OFF cycling the compressor of a direct expansion (DX) air conditioning (A/C) system, leaving the indoor humidity uncontrolled. In some areas, the large latent cooling load will lead to an unstable and high indoor humidity, resulting in deteriorating thermal comfort, indoor air quality and energy efficiency, suggesting that an actively controlled humidity is indispensable. The existing temperature and humidity independent control (THIC) methods are too complicated to be suitable for applying in small buildings. Therefore, the authors established a water chiller which can be applied in residential buildings for THIC by using a dual-evaporation-temperature compressor. A prototype was built and experimentally tested. Results showed that in the varying summer condition, the high and low water supplying temperatures were maintained around 18.8°C and 7.8°C, respectively, suggesting that this novel chiller could provide chilled water of two different temperatures for THIC. Furthermore, the energy efficiency ratios (EER) of the compressor was 3.5, which was comparable to those conventional DX A/C systems or chillers of the same size. Therefore, this novel chiller based on dual evaporation temperatures was feasible.</p>","PeriodicalId":627,"journal":{"name":"Journal of Engineering Thermophysics","volume":"32 2","pages":"360 - 377"},"PeriodicalIF":1.3000,"publicationDate":"2023-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Engineering Thermophysics","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1134/S181023282302011X","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Indoor environment control strategies in small buildings are simply considered, such as achieving the indoor temperature control through ON/OFF cycling the compressor of a direct expansion (DX) air conditioning (A/C) system, leaving the indoor humidity uncontrolled. In some areas, the large latent cooling load will lead to an unstable and high indoor humidity, resulting in deteriorating thermal comfort, indoor air quality and energy efficiency, suggesting that an actively controlled humidity is indispensable. The existing temperature and humidity independent control (THIC) methods are too complicated to be suitable for applying in small buildings. Therefore, the authors established a water chiller which can be applied in residential buildings for THIC by using a dual-evaporation-temperature compressor. A prototype was built and experimentally tested. Results showed that in the varying summer condition, the high and low water supplying temperatures were maintained around 18.8°C and 7.8°C, respectively, suggesting that this novel chiller could provide chilled water of two different temperatures for THIC. Furthermore, the energy efficiency ratios (EER) of the compressor was 3.5, which was comparable to those conventional DX A/C systems or chillers of the same size. Therefore, this novel chiller based on dual evaporation temperatures was feasible.

Abstract Image

家用双蒸发温度制冷机的实验研究
简单考虑了小型建筑的室内环境控制策略,例如通过开/关循环直扩空调(DX)系统的压缩机实现室内温度控制,使室内湿度不受控制。在某些地区,大的潜在冷负荷会导致室内湿度不稳定和高,从而导致热舒适、室内空气质量和能源效率的恶化,这表明主动控制湿度是必不可少的。现有的温湿度独立控制方法过于复杂,不适合在小型建筑中应用。为此,笔者研制了一种采用双蒸发温度压缩机的住宅用冷水机组。制作了一个原型并进行了实验测试。结果表明,在不同的夏季条件下,供水最高温度和最低温度分别维持在18.8°C和7.8°C左右,表明该新型制冷机可以为生物流化床提供两种不同温度的冷冻水。此外,压缩机的能效比(EER)为3.5,与传统的DX空调系统或相同尺寸的冷水机组相当。因此,这种基于双蒸发温度的新型制冷机是可行的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Engineering Thermophysics
Journal of Engineering Thermophysics THERMODYNAMICS-ENGINEERING, MECHANICAL
CiteScore
2.30
自引率
12.50%
发文量
0
审稿时长
3 months
期刊介绍: Journal of Engineering Thermophysics is an international peer reviewed journal that publishes original articles. The journal welcomes original articles on thermophysics from all countries in the English language. The journal focuses on experimental work, theory, analysis, and computational studies for better understanding of engineering and environmental aspects of thermophysics. The editorial board encourages the authors to submit papers with emphasis on new scientific aspects in experimental and visualization techniques, mathematical models of thermophysical process, energy, and environmental applications. Journal of Engineering Thermophysics covers all subject matter related to thermophysics, including heat and mass transfer, multiphase flow, conduction, radiation, combustion, thermo-gas dynamics, rarefied gas flow, environmental protection in power engineering, and many others.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信