Optimization of a Gas Chromatography–Mass Spectrometry (GCMS) Method for Detecting 28 Allergens in Various Personal Care Products

IF 3.4 Q2 BIOCHEMISTRY & MOLECULAR BIOLOGY
Adnan S. AL-Mussallam, Abdullah T. Bawazir, Rawan S. Alshathri, Omniyah Alharthi, F. Aldawsari
{"title":"Optimization of a Gas Chromatography–Mass Spectrometry (GCMS) Method for Detecting 28 Allergens in Various Personal Care Products","authors":"Adnan S. AL-Mussallam, Abdullah T. Bawazir, Rawan S. Alshathri, Omniyah Alharthi, F. Aldawsari","doi":"10.3390/cosmetics10030091","DOIUrl":null,"url":null,"abstract":"Fragrances are among the most common ingredients in cosmetics products. Importantly, exposure to fragrances on a daily basis might pose a health risk, leading to serious effects, such as contact dermatitis or contact eczema. Annex III of the European Union Directive on Cosmetic Products and Gulf Cooperation Council standardization organization (GSO) introduced restrictions for 26 allergens, with their concentrations exceeding 0.001% and 0.01% in leave-on products and rinse-off products, respectively. In the current study, we aimed to expand the scope of the analytical method (EN16274, 2012) to include a broader range of matrices. The optimized method was validated by examining a statistical approach, including selectivity, linearity, accuracy, precision, and measurement of uncertainty. Successfully, the validated data demonstrated acceptable limits according to validation protocols, with linearity showing satisfactory regression of r > 0.995. During method performance assessment, samples were extracted using ultrasound-assisted extraction to extract allergens that yielded relatively high recoveries. Studies on matrices spiked with allergens at different levels showed insignificant bias as an average of 0.07 µg/g. Method performance was assessed by analyzing 140 cosmetics samples, including perfumes, deodorants, aftershave, baby wet wipes, shampoos, lotions, and lip care products. The new optimized analytical method is believed to be a valuable analytical tool to be used in surveillance studies covering a wide range of cosmetic matrices.","PeriodicalId":10735,"journal":{"name":"Cosmetics","volume":" ","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2023-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cosmetics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/cosmetics10030091","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 1

Abstract

Fragrances are among the most common ingredients in cosmetics products. Importantly, exposure to fragrances on a daily basis might pose a health risk, leading to serious effects, such as contact dermatitis or contact eczema. Annex III of the European Union Directive on Cosmetic Products and Gulf Cooperation Council standardization organization (GSO) introduced restrictions for 26 allergens, with their concentrations exceeding 0.001% and 0.01% in leave-on products and rinse-off products, respectively. In the current study, we aimed to expand the scope of the analytical method (EN16274, 2012) to include a broader range of matrices. The optimized method was validated by examining a statistical approach, including selectivity, linearity, accuracy, precision, and measurement of uncertainty. Successfully, the validated data demonstrated acceptable limits according to validation protocols, with linearity showing satisfactory regression of r > 0.995. During method performance assessment, samples were extracted using ultrasound-assisted extraction to extract allergens that yielded relatively high recoveries. Studies on matrices spiked with allergens at different levels showed insignificant bias as an average of 0.07 µg/g. Method performance was assessed by analyzing 140 cosmetics samples, including perfumes, deodorants, aftershave, baby wet wipes, shampoos, lotions, and lip care products. The new optimized analytical method is believed to be a valuable analytical tool to be used in surveillance studies covering a wide range of cosmetic matrices.
气相色谱-质谱(GCMS)检测各种个人护理产品中28种过敏原的方法优化
香水是化妆品中最常见的成分之一。重要的是,每天接触香水可能会对健康构成风险,导致严重影响,如接触性皮炎或接触性湿疹。欧盟化妆品指令附件三和海湾合作委员会标准化组织(GSO)对26种过敏原进行了限制,其在免洗产品和冲洗产品中的浓度分别超过0.001%和0.01%。在当前的研究中,我们旨在扩大分析方法(EN162742012)的范围,以包括更广泛的矩阵。通过检验统计方法验证了优化方法,包括选择性、线性、准确性、精密度和不确定度测量。根据验证方案,验证数据成功地证明了可接受的限度,线性回归令人满意,r>0.995。在方法性能评估过程中,使用超声波辅助提取提取样品,以提取回收率相对较高的过敏原。对掺入不同水平过敏原的基质的研究表明,偏差不显著,平均为0.07µg/g。方法通过分析140种化妆品样品来评估性能,包括香水、除臭剂、须后水、婴儿湿巾、洗发水、乳液和唇部护理产品。新的优化分析方法被认为是一种有价值的分析工具,可用于涵盖广泛化妆品基质的监测研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Cosmetics
Cosmetics Medicine-Surgery
CiteScore
5.20
自引率
12.10%
发文量
108
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信