Evaluation of anterior chamber volume using Pentacam and anterior segment optical coherence tomography among normal subjects

Q4 Medicine
Vijaya Anandan, Rekha Srinivasan, R. Asokan, R. George
{"title":"Evaluation of anterior chamber volume using Pentacam and anterior segment optical coherence tomography among normal subjects","authors":"Vijaya Anandan, Rekha Srinivasan, R. Asokan, R. George","doi":"10.35119/asjoo.v16i2.367","DOIUrl":null,"url":null,"abstract":"Aim: To compare the anterior chamber volume measurements obtained with Pentacam and derived from anterior segment optical coherence tomography. \nDesign: Cross-sectional study. \nMethods: We included normal subjects who underwent a comprehensive eye examination including refraction, keratometry, Goldmann applanation tonometry, gonioscopy, anterior segment optical coherence tomography (AS-OCT) (Carl Zeiss Meditec Inc.; Dublin, CA, USA) and Pentacam (Oculus Inc.; Lynnwood, WA, USA). Fifty scans were selected for Pentacam and 12 images were selected for calculation of anterior chamber volume. Only the right eye was considered for analysis. \nResults: One-hundred and nineteen eyes of 119 subjects were included for analysis. The mean age of the subjects was 42.58 ± 13.15 years, of which 74 were female and 45 were male. The mean anterior chamber volume measured using AS-OCT was 119.17 ± 26.56 mm3 and with Pentacam was 131.29 ± 34.26 mm3. The comparison of means between the two modalities was statistically significant (t = -8.857, Mean Difference (MD) = 12.11, 95% CI: (4.29, 19.95), p = 0.003). Bland-Altman plot showed poor agreement between the chamber volume measurements obtained by Pentacam and AS-OCT with MD of 12.1 mm3 (95 % CI: 41.4 to -17.1) and intra-class correlation between the two instruments was 0.94 (95% CI: 0.91, 0.96) (p < 0.0001). \nConclusion: The anterior chamber volume can be measured using Pentacam as well as AS-OCT since these measurements were reliable. However, these measurements were not interchangeable due to poor levels of agreement.","PeriodicalId":39864,"journal":{"name":"Asian Journal of Ophthalmology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35119/asjoo.v16i2.367","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: To compare the anterior chamber volume measurements obtained with Pentacam and derived from anterior segment optical coherence tomography. Design: Cross-sectional study. Methods: We included normal subjects who underwent a comprehensive eye examination including refraction, keratometry, Goldmann applanation tonometry, gonioscopy, anterior segment optical coherence tomography (AS-OCT) (Carl Zeiss Meditec Inc.; Dublin, CA, USA) and Pentacam (Oculus Inc.; Lynnwood, WA, USA). Fifty scans were selected for Pentacam and 12 images were selected for calculation of anterior chamber volume. Only the right eye was considered for analysis. Results: One-hundred and nineteen eyes of 119 subjects were included for analysis. The mean age of the subjects was 42.58 ± 13.15 years, of which 74 were female and 45 were male. The mean anterior chamber volume measured using AS-OCT was 119.17 ± 26.56 mm3 and with Pentacam was 131.29 ± 34.26 mm3. The comparison of means between the two modalities was statistically significant (t = -8.857, Mean Difference (MD) = 12.11, 95% CI: (4.29, 19.95), p = 0.003). Bland-Altman plot showed poor agreement between the chamber volume measurements obtained by Pentacam and AS-OCT with MD of 12.1 mm3 (95 % CI: 41.4 to -17.1) and intra-class correlation between the two instruments was 0.94 (95% CI: 0.91, 0.96) (p < 0.0001). Conclusion: The anterior chamber volume can be measured using Pentacam as well as AS-OCT since these measurements were reliable. However, these measurements were not interchangeable due to poor levels of agreement.
使用Pentacam和前段光学相干断层扫描评估正常人前房容积
目的:比较Pentacam和前房光学相干断层扫描的前房容积测量结果。设计:横断面研究。方法:我们纳入了接受全面眼科检查的正常受试者,包括屈光、角膜测量、Goldmann屈光眼压、角膜镜检查、前段光学相干断层扫描(AS-OCT) (Carl Zeiss Meditec Inc.;都柏林,加州,美国)和Pentacam (Oculus Inc.;Lynnwood, WA, USA)。Pentacam扫描50张,计算前房容积12张。只有右眼被考虑进行分析。结果:纳入119名受试者的119只眼进行分析。受试者平均年龄42.58±13.15岁,其中女性74人,男性45人。AS-OCT测量的平均前房容积为119.17±26.56 mm3, Pentacam测量的平均前房容积为131.29±34.26 mm3。两种方式的均数比较具有统计学意义(t = -8.857, Mean Difference (MD) = 12.11, 95% CI: (4.29, 19.95), p = 0.003)。Bland-Altman图显示Pentacam和AS-OCT获得的腔室容积测量结果不一致,MD为12.1 mm3 (95% CI: 41.4至-17.1),两种仪器之间的类内相关性为0.94 (95% CI: 0.91, 0.96) (p < 0.0001)。结论:使用Pentacam和as - oct测量前房容积是可靠的。然而,由于一致性差,这些测量结果不能互换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Asian Journal of Ophthalmology
Asian Journal of Ophthalmology Medicine-Ophthalmology
自引率
0.00%
发文量
0
期刊介绍: Asian Journal of OPHTHALMOLOGY is the official peer-reviewed journal of the South East Asia Glaucoma Interest Group (SEAGIG) and is indexed in EMBASE/Excerpta Medica. Asian Journal of OPHTHALMOLOGY is published quarterly (four [4] issues per year) by Scientific Communications International Limited. The journal is published on-line only and is distributed free of cost via the SEAGIG website.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信