Impact of Tube Voltage on Radiation Dose (CTDI) and Image Quality at Chest CT Examination

IF 0.6 Q4 NUCLEAR SCIENCE & TECHNOLOGY
M. E. Mansouri, A. Choukri, M. Talbi, O. Hakam
{"title":"Impact of Tube Voltage on Radiation Dose (CTDI) and Image Quality at Chest CT Examination","authors":"M. E. Mansouri, A. Choukri, M. Talbi, O. Hakam","doi":"10.17146/aij.2021.1120","DOIUrl":null,"url":null,"abstract":"During Computed Tomography (CT) scan examinations, it is important to ensure a good diagnosis by providing the maximum information to detect pathologies and this can be done with a reduced dose. In this respect, several methods of dose reduction have been studied and evaluated. This work investigates the effect of tube voltage while varying the tube current on image quality and radiation dose at Chest CT examination. This study was conducted on HITACHI CT 16 slice Scanner using two phantoms for evaluating the dose and image quality; a PMMA phantom and a CATPHAN 500. Two tube voltages of 120 KVp and 100 KVp have been used for some variation of the tube currents (mAs) and recording the values of the measured quantities (CTDIv, spatial resolution, contrast to noise ratio CNR and noise). The scanning with 100 KVp at Chest CT examination led to a reduction in CTDIv until 45 %, an increase of noise from 17 % to 45 %, and the Spatial Resolution fell slightly (6 and 7 pl/cm) compared to the 120 KVp. The CNR shows a slight regression from 11 to 22 % for the 120 KVp and 100 KVp. This study has shown that despite the increase in the image noise at low tube voltage 100 KVp, it is possible to reduce the radiation dose by up to 45 % without degradation of image quality at Chest CT examination. Further works will evaluate the effect of acquisition parameters in other CT examinations.","PeriodicalId":8647,"journal":{"name":"Atom Indonesia","volume":" ","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2021-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atom Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17146/aij.2021.1120","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 9

Abstract

During Computed Tomography (CT) scan examinations, it is important to ensure a good diagnosis by providing the maximum information to detect pathologies and this can be done with a reduced dose. In this respect, several methods of dose reduction have been studied and evaluated. This work investigates the effect of tube voltage while varying the tube current on image quality and radiation dose at Chest CT examination. This study was conducted on HITACHI CT 16 slice Scanner using two phantoms for evaluating the dose and image quality; a PMMA phantom and a CATPHAN 500. Two tube voltages of 120 KVp and 100 KVp have been used for some variation of the tube currents (mAs) and recording the values of the measured quantities (CTDIv, spatial resolution, contrast to noise ratio CNR and noise). The scanning with 100 KVp at Chest CT examination led to a reduction in CTDIv until 45 %, an increase of noise from 17 % to 45 %, and the Spatial Resolution fell slightly (6 and 7 pl/cm) compared to the 120 KVp. The CNR shows a slight regression from 11 to 22 % for the 120 KVp and 100 KVp. This study has shown that despite the increase in the image noise at low tube voltage 100 KVp, it is possible to reduce the radiation dose by up to 45 % without degradation of image quality at Chest CT examination. Further works will evaluate the effect of acquisition parameters in other CT examinations.
胸部CT检查中管电压对辐射剂量(CTDI)和图像质量的影响
在计算机断层扫描(CT)检查中,重要的是通过提供最大的信息来检测病理,以确保良好的诊断,这可以通过减少剂量来完成。在这方面,已经研究和评价了几种减少剂量的方法。本文研究了不同管电流下管电压对胸部CT成像质量和辐射剂量的影响。本研究在日立CT 16层扫描仪上进行,采用双影法评估剂量和图像质量;一个PMMA幻影和一个CATPHAN 500。用120 KVp和100 KVp两个管电压对管电流(mAs)进行了一些变化,并记录了测量量(CTDIv、空间分辨率、噪声比CNR和噪声)的值。在胸部CT检查中,100 KVp扫描导致CTDIv降低至45%,噪声从17%增加到45%,与120 KVp相比,空间分辨率略有下降(6和7 pl/cm)。对于120 KVp和100 KVp, CNR从11%到22%略有回归。本研究表明,尽管在低管电压100 KVp下图像噪声增加,但在胸部CT检查时,可以将辐射剂量降低高达45%而不降低图像质量。进一步的工作将评估采集参数在其他CT检查中的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Atom Indonesia
Atom Indonesia NUCLEAR SCIENCE & TECHNOLOGY-
CiteScore
1.00
自引率
0.00%
发文量
20
审稿时长
16 weeks
期刊介绍: The focus of Atom Indonesia is research and development in nuclear science and technology. The scope of this journal covers experimental and analytical research in nuclear science and technology. The topics include nuclear physics, reactor physics, radioactive waste, fuel element, radioisotopes, radiopharmacy, radiation, and neutron scattering, as well as their utilization in agriculture, industry, health, environment, energy, material science and technology, and related fields.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信