{"title":"Magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) hyperthermia for primary rectal cancer: A virtual feasibility analysis.","authors":"K. Perry, R. Staruch, S. Pichardo, Yuexi Huang, M. McGuffin, A. Partanen, Shun Wong, G. Czarnota, K. Hynynen, Kelvin K. W. Chan, W. Chu","doi":"10.1200/jgo.2019.5.suppl.77","DOIUrl":null,"url":null,"abstract":"77 Background: MR-HIFU Hyperthermia (HT) is a non-invasive treatment modality with real-time thermometry that ensures accurate and precise heating of a target with minimal effect on adjacent tissue. This energy deposition within a tumour can produce local bioeffects resulting in thermal chemo- and radiosensitization. MR-HIFU has been shown to be safe and feasible in a companion phase I study for recurrent rectal cancer. The purpose of this study is to determine the feasibility of MR-HIFU in treating primary rectal tumours. Methods: With ethics approval, the anatomic characteristics and surrounding structures of rectal tumours diagnosed at Sunnybrook from 2014-2019 were retrospectively analyzed. Three orthogonal views of MR images were used to determine the potential ultrasound (US) beam path and organs at risk (OAR). In part 2 of the study, the gross tumour volume was delineated for 30 rectal tumours (10 low, mid &high). Image datasets were imported into the Sonalleve MR-HIFU workstation for virtual treatment simulation and planning to determine tumour targetability, coverage, optimal patient set-up, and transducer positioning. Results: Of the 105 tumours analyzed, 36, 52, and 17 were low, mid, and high, respectively. The average width of the acoustic window (sciatic notch) for the US beam path was 5.8 ± 1.4cm, average tumour length was 5.24 ± 2.0cm, and average beam path (skin to tumour edge) was 7.3 ± 1.9cm. Eighty one percent of tumours were ≤ 0.3cm from an OAR. Of the 24 virtually simulated tumours to date, 6/8 lower, 6/8 mid, and 1/8 upper rectal tumours were targetable by MR-HIFU. Conclusions: This is the first virtual analysis to evaluate MR-HIFU HT targetability in primary rectal cancer. Results from this study will support MR-HIFU HT as an option to enhance the treatment of primary rectal cancer. Acknowledgments: This study has been funded by the Canadian Cancer Society. Patient & tumour characteristics. [Table: see text]","PeriodicalId":15862,"journal":{"name":"Journal of global oncology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of global oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1200/jgo.2019.5.suppl.77","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

77 Background: MR-HIFU Hyperthermia (HT) is a non-invasive treatment modality with real-time thermometry that ensures accurate and precise heating of a target with minimal effect on adjacent tissue. This energy deposition within a tumour can produce local bioeffects resulting in thermal chemo- and radiosensitization. MR-HIFU has been shown to be safe and feasible in a companion phase I study for recurrent rectal cancer. The purpose of this study is to determine the feasibility of MR-HIFU in treating primary rectal tumours. Methods: With ethics approval, the anatomic characteristics and surrounding structures of rectal tumours diagnosed at Sunnybrook from 2014-2019 were retrospectively analyzed. Three orthogonal views of MR images were used to determine the potential ultrasound (US) beam path and organs at risk (OAR). In part 2 of the study, the gross tumour volume was delineated for 30 rectal tumours (10 low, mid &high). Image datasets were imported into the Sonalleve MR-HIFU workstation for virtual treatment simulation and planning to determine tumour targetability, coverage, optimal patient set-up, and transducer positioning. Results: Of the 105 tumours analyzed, 36, 52, and 17 were low, mid, and high, respectively. The average width of the acoustic window (sciatic notch) for the US beam path was 5.8 ± 1.4cm, average tumour length was 5.24 ± 2.0cm, and average beam path (skin to tumour edge) was 7.3 ± 1.9cm. Eighty one percent of tumours were ≤ 0.3cm from an OAR. Of the 24 virtually simulated tumours to date, 6/8 lower, 6/8 mid, and 1/8 upper rectal tumours were targetable by MR-HIFU. Conclusions: This is the first virtual analysis to evaluate MR-HIFU HT targetability in primary rectal cancer. Results from this study will support MR-HIFU HT as an option to enhance the treatment of primary rectal cancer. Acknowledgments: This study has been funded by the Canadian Cancer Society. Patient & tumour characteristics. [Table: see text]
磁共振引导高强度聚焦超声(MR-HIFU)热疗治疗原发性癌症:一项虚拟可行性分析。
背景:MR-HIFU热疗(HT)是一种非侵入性的治疗方式,具有实时测温功能,可确保在对邻近组织影响最小的情况下准确和精确地加热目标。肿瘤内的能量沉积可产生局部生物效应,导致热化疗和放射致敏。在一项治疗复发性直肠癌的一期研究中,MR-HIFU已被证明是安全可行的。本研究的目的是确定mri - hifu治疗原发性直肠肿瘤的可行性。方法:经伦理批准,回顾性分析2014-2019年在森尼布鲁克诊断的直肠肿瘤的解剖特征和周围结构。采用磁共振成像的三个正交视图来确定潜在的超声(US)波束路径和危险器官(OAR)。在研究的第二部分,勾画了30个直肠肿瘤的总肿瘤体积(低、中、高各10个)。将图像数据集导入Sonalleve MR-HIFU工作站,进行虚拟治疗模拟和规划,以确定肿瘤的靶向性、覆盖范围、最佳患者设置和传感器定位。结果:105例肿瘤中,低、中、高肿瘤分别为36例、52例和17例。US束路声窗(坐骨切迹)的平均宽度为5.8±1.4cm,平均肿瘤长度为5.24±2.0cm,平均束路(皮肤到肿瘤边缘)为7.3±1.9cm。81%的肿瘤距桨部≤0.3cm。在迄今为止的24个虚拟模拟肿瘤中,6/8的直肠下部肿瘤、6/8的直肠中部肿瘤和1/8的直肠上部肿瘤是MR-HIFU可靶向的。结论:这是第一个评估MR-HIFU HT在原发性直肠癌中的靶向性的虚拟分析。这项研究的结果将支持MR-HIFU HT作为加强原发性直肠癌治疗的一种选择。致谢:本研究由加拿大癌症协会资助。患者及肿瘤特征。[表:见正文]
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
20 weeks
期刊介绍: The Journal of Global Oncology (JGO) is an online only, open access journal focused on cancer care, research and care delivery issues unique to countries and settings with limited healthcare resources. JGO aims to provide a home for high-quality literature that fulfills a growing need for content describing the array of challenges health care professionals in resource-constrained settings face. Article types include original reports, review articles, commentaries, correspondence/replies, special articles and editorials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信