A Pilot Study to Assess the Feasibility of Comparing Ultra-High Pressure to Low-Pressure Fire Suppression Systems for a Simulated Indirect Exterior Attack
{"title":"A Pilot Study to Assess the Feasibility of Comparing Ultra-High Pressure to Low-Pressure Fire Suppression Systems for a Simulated Indirect Exterior Attack","authors":"E. Sanli, Robert Brown, Derek Simmons","doi":"10.3390/fire6070278","DOIUrl":null,"url":null,"abstract":"Financial and human resource challenges constrain firefighting in rural communities. This can limit the approaches that can be used in a given residential fire situation. Effective use of portable, lower-cost equipment that would require fewer personnel and less water could greatly benefit rural communities. This study was conducted to assess the feasibility of comparing ultra-high-pressure to low-pressure fire suppression systems at low flow rates. The conditions used simulated an indirect exterior attack through a window. A purpose-built burn room and standardized class A fires were used to compare ultra-high-pressure and low-pressure systems at low flow rates. Temperatures in the burn room were recorded for each condition in triplicate. While neither operating condition resulted in full extinguishment of the fire, the ultra-high-pressure trials saw decreases in the proportion of starting temperature that were faster and of greater magnitude than for the low-pressure trials. This compares with earlier research, simulating a transitional attack that saw similar patterns for temperature cooling but resulted in extinguishment. This preliminary testing provides evidence that the burn container and room, as well as instrumentation and fuel load configurations, are appropriate for more extensive testing of such equipment for exterior fire suppression.","PeriodicalId":36395,"journal":{"name":"Fire-Switzerland","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2023-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire-Switzerland","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.3390/fire6070278","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ECOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Financial and human resource challenges constrain firefighting in rural communities. This can limit the approaches that can be used in a given residential fire situation. Effective use of portable, lower-cost equipment that would require fewer personnel and less water could greatly benefit rural communities. This study was conducted to assess the feasibility of comparing ultra-high-pressure to low-pressure fire suppression systems at low flow rates. The conditions used simulated an indirect exterior attack through a window. A purpose-built burn room and standardized class A fires were used to compare ultra-high-pressure and low-pressure systems at low flow rates. Temperatures in the burn room were recorded for each condition in triplicate. While neither operating condition resulted in full extinguishment of the fire, the ultra-high-pressure trials saw decreases in the proportion of starting temperature that were faster and of greater magnitude than for the low-pressure trials. This compares with earlier research, simulating a transitional attack that saw similar patterns for temperature cooling but resulted in extinguishment. This preliminary testing provides evidence that the burn container and room, as well as instrumentation and fuel load configurations, are appropriate for more extensive testing of such equipment for exterior fire suppression.