Optimizing the phase sensitivity of Michelson interferometer with two-mode squeezed coherent input in the presence of loss and noise

IF 4.2 Q2 QUANTUM SCIENCE & TECHNOLOGY
Stav Haldar, Pratik J. Barge, Xiaoqi Xiao, Hwangsuk Lee
{"title":"Optimizing the phase sensitivity of Michelson interferometer with two-mode squeezed coherent input in the presence of loss and noise","authors":"Stav Haldar, Pratik J. Barge, Xiaoqi Xiao, Hwangsuk Lee","doi":"10.1116/5.0148632","DOIUrl":null,"url":null,"abstract":"A Michelson-type interferometer with two-mode squeezed coherent state input is considered. Such an interferometer has a better phase sensitivity over the shot-noise limit by a factor of e2r, where r is the squeezing parameter [Phys. Rev. A 102, 022614 (2020)]. We show that when photon loss and noise in the two arms are asymmetric, an optimal choice of the squeezing angle can allow improvement in phase sensitivity without any increase in input or pump power. In particular, when loss occurs only in one arm of the interferometer, we can have improvement in phase sensitivity for photon loss up to 80%. Hence, a significant improvement can be made in several applications such as LiDAR, gyroscopes, and measuring refractive indices of highly absorptive/reflective materials.","PeriodicalId":93525,"journal":{"name":"AVS quantum science","volume":" ","pages":""},"PeriodicalIF":4.2000,"publicationDate":"2023-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AVS quantum science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1116/5.0148632","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"QUANTUM SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

A Michelson-type interferometer with two-mode squeezed coherent state input is considered. Such an interferometer has a better phase sensitivity over the shot-noise limit by a factor of e2r, where r is the squeezing parameter [Phys. Rev. A 102, 022614 (2020)]. We show that when photon loss and noise in the two arms are asymmetric, an optimal choice of the squeezing angle can allow improvement in phase sensitivity without any increase in input or pump power. In particular, when loss occurs only in one arm of the interferometer, we can have improvement in phase sensitivity for photon loss up to 80%. Hence, a significant improvement can be made in several applications such as LiDAR, gyroscopes, and measuring refractive indices of highly absorptive/reflective materials.
有损耗和噪声时双模压缩相干输入迈克尔逊干涉仪相位灵敏度的优化
考虑了一种具有双模压缩相干态输入的迈克尔逊干涉仪。这种干涉仪具有比散粒噪声极限高出e2r因子的更好的相位灵敏度,其中r是压缩参数[Phys.Rev.A10022614(2020)]。我们表明,当两臂中的光子损耗和噪声不对称时,压缩角的最佳选择可以在不增加输入或泵浦功率的情况下提高相位灵敏度。特别是,当损耗仅发生在干涉仪的一个臂中时,我们可以将光子损耗的相位灵敏度提高到80%。因此,可以在诸如激光雷达、陀螺仪和测量高吸收/反射材料的折射率的几个应用中进行显著改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
9.90
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信