Indoor Air Factors Affecting the Growth of Microorganism in an Indonesian Gas Company’s Dormitory

S. M. Nasri, Asduki D. Athari, L. R. Hastiti, Fiori Amelia Putri
{"title":"Indoor Air Factors Affecting the Growth of Microorganism in an Indonesian Gas Company’s Dormitory","authors":"S. M. Nasri, Asduki D. Athari, L. R. Hastiti, Fiori Amelia Putri","doi":"10.20473/ijosh.v11i3.2022.445-453","DOIUrl":null,"url":null,"abstract":"Introduction: Mold may affect the Indoor Air Quality (IAQ) in workplace dormitories. This study aims to investigate indoor air factors that affect molds growth in a dormitory of an LNG Company in Indonesia. Several indoor air determinant factors, including relative humidity, general temperature, wet temperature, dry temperature, air velocity, illumination, particulate matter, and carbon dioxide concentration were assessed against the growth of microorganism colonies. Methods: This study was a cross-sectional study using a 2 (two)-stage Andersen sampler based on NIOSH 0800 Bioaerosol Sampling Method for Indoor Air Quality for viable bioaerosol sampling. Bioaerosol samples were collected from 50 indoor, corridor, and outdoor sampling points. The total colony count for bioaerosols (TCC) was then determined (CFU/m3). Ten indoor air quality parameters, i.e., relative humidity, general temperature, wet temperature, dry temperature, air velocity, illumination, particulate matter, and carbon dioxide concentration, were measured. Results: The average mold colony concentration in the dormitory rooms was higher (703.1 CFU/m3) than the maximum standard issued by the Ministry of Health of the Republic of Indonesia (< 700 CFU/m3) while the relative humidity was very high (84.4% RH on average), with a direct relation between the humidity and the mold colony concentration. A significant correlation was also identified between mold colony concentration, wet temperature, and CO2 concentration. Conclusion: Significant correlations between bioaerosols, relative humidity, wet temperature, and indoor CO2 concentration indicate insufficient ventilation and poor indoor air quality in the dormitory.","PeriodicalId":33133,"journal":{"name":"The Indonesian Journal of Occupational Safety and Health","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Indonesian Journal of Occupational Safety and Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20473/ijosh.v11i3.2022.445-453","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Mold may affect the Indoor Air Quality (IAQ) in workplace dormitories. This study aims to investigate indoor air factors that affect molds growth in a dormitory of an LNG Company in Indonesia. Several indoor air determinant factors, including relative humidity, general temperature, wet temperature, dry temperature, air velocity, illumination, particulate matter, and carbon dioxide concentration were assessed against the growth of microorganism colonies. Methods: This study was a cross-sectional study using a 2 (two)-stage Andersen sampler based on NIOSH 0800 Bioaerosol Sampling Method for Indoor Air Quality for viable bioaerosol sampling. Bioaerosol samples were collected from 50 indoor, corridor, and outdoor sampling points. The total colony count for bioaerosols (TCC) was then determined (CFU/m3). Ten indoor air quality parameters, i.e., relative humidity, general temperature, wet temperature, dry temperature, air velocity, illumination, particulate matter, and carbon dioxide concentration, were measured. Results: The average mold colony concentration in the dormitory rooms was higher (703.1 CFU/m3) than the maximum standard issued by the Ministry of Health of the Republic of Indonesia (< 700 CFU/m3) while the relative humidity was very high (84.4% RH on average), with a direct relation between the humidity and the mold colony concentration. A significant correlation was also identified between mold colony concentration, wet temperature, and CO2 concentration. Conclusion: Significant correlations between bioaerosols, relative humidity, wet temperature, and indoor CO2 concentration indicate insufficient ventilation and poor indoor air quality in the dormitory.
印尼某燃气公司宿舍室内空气因素对微生物生长的影响
引言:霉菌可能会影响工作场所宿舍的室内空气质量。本研究旨在调查影响印尼一家液化天然气公司宿舍霉菌生长的室内空气因素。针对微生物菌落的生长,评估了几个室内空气决定因素,包括相对湿度、一般温度、潮湿温度、干燥温度、空气速度、光照、颗粒物和二氧化碳浓度。方法:本研究是一项横断面研究,使用基于NIOSH 0800《室内空气质量生物气溶胶采样方法》的2(两)级Andersen采样器进行可行的生物气溶胶采样。从50个室内、走廊和室外采样点采集生物气溶胶样本。然后测定生物气溶胶(TCC)的总菌落计数(CFU/m3)。测量了10个室内空气质量参数,即相对湿度、一般温度、湿温、干温、风速、光照、颗粒物和二氧化碳浓度。结果:宿舍房间的平均菌落浓度(703.1CFU/m3)高于印度尼西亚卫生部颁布的最高标准(<700CFU/m3,而相对湿度很高(平均84.4%RH),湿度与菌落浓度有直接关系。菌落浓度、潮湿温度和CO2浓度之间也存在显著相关性。结论:生物气溶胶、相对湿度、湿温和室内CO2浓度之间存在显著相关性,表明宿舍通风不足,室内空气质量较差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
40
审稿时长
5 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信