A 3D printed positioner for hip rotation center used in total hip arthroplasty

Q4 Medicine
Yuehui Wang, Liangliang Cao, Shiping Zou, Wenteng Si, Aiguo Wang, Cheng-wei Chen
{"title":"A 3D printed positioner for hip rotation center used in total hip arthroplasty","authors":"Yuehui Wang, Liangliang Cao, Shiping Zou, Wenteng Si, Aiguo Wang, Cheng-wei Chen","doi":"10.3760/CMA.J.CN115530-20190615-00208","DOIUrl":null,"url":null,"abstract":"Objective \nTo evaluate the application of a 3D printed positioner for hip rotation center in total hip arthroplasty. \n \n \nMethods \nFrom August 2015 to December 2017, 14 patients were treated by unilateral total hip arthroplasty at Department Ⅰ of Joint Surgery, Orthopaedics Hospital of Zhengzhou for avascular necrosis of femoral head or femoral neck fracture. They were 8 males and 6 females with an average age of 51.8 years (from 37 to 65 years). All their surgeries were assisted by a 3D printed positioner for hip rotation center. Postoperatively, the abduction and anteversion of acetabular cup and the hip rotation center were measured, the agreement between the hip rotation center of the affected side (O2) and the anatomical rotation center of the healthy side (O1) was assessed, and the function of the affected hip and complications were recorded at the last follow-up. \n \n \nResults \nThe 14 patients were followed up for an average of 18 months (from 6 to 24 months). The postoperative ordinates of O2 and O1 were respectively 19.36 mm±3.61 mm and 18.33 mm±3.41 mm while their abscissas 39.93 mm±2.97 mm and 39.99 mm±3.16 mm, indicating agreement between O2 and O1 (P>0.05). The postoperative abduction and anteversion of the cup were within a normal range (39.3°±3.2°and 14.6°±1.2°, respectively). The last follow-up showed that their preoperative Harris hip scores (42.3±3.2) were significantly improved (94.3±4.7) (t=2.873, P=0.002) and that 13 cases were rated as excellent and one as good. X-ray follow-up showed good position of their acetabular prostheses, no loosening of the cups or femoral prostheses, and no heterotopic ossification. \n \n \nConclusion \nA 3D printed positioner for hip rotation center can effectively assist reconstruction of the hip rotation center and accurate implantation of acetabular prosthesis in total hip arthroplasty. \n \n \nKey words: \nArthroplasty, replacement, hip; 3D printing techniques; Center of rotation; Positioner","PeriodicalId":10145,"journal":{"name":"中华创伤骨科杂志","volume":"22 1","pages":"243-248"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华创伤骨科杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.CN115530-20190615-00208","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective To evaluate the application of a 3D printed positioner for hip rotation center in total hip arthroplasty. Methods From August 2015 to December 2017, 14 patients were treated by unilateral total hip arthroplasty at Department Ⅰ of Joint Surgery, Orthopaedics Hospital of Zhengzhou for avascular necrosis of femoral head or femoral neck fracture. They were 8 males and 6 females with an average age of 51.8 years (from 37 to 65 years). All their surgeries were assisted by a 3D printed positioner for hip rotation center. Postoperatively, the abduction and anteversion of acetabular cup and the hip rotation center were measured, the agreement between the hip rotation center of the affected side (O2) and the anatomical rotation center of the healthy side (O1) was assessed, and the function of the affected hip and complications were recorded at the last follow-up. Results The 14 patients were followed up for an average of 18 months (from 6 to 24 months). The postoperative ordinates of O2 and O1 were respectively 19.36 mm±3.61 mm and 18.33 mm±3.41 mm while their abscissas 39.93 mm±2.97 mm and 39.99 mm±3.16 mm, indicating agreement between O2 and O1 (P>0.05). The postoperative abduction and anteversion of the cup were within a normal range (39.3°±3.2°and 14.6°±1.2°, respectively). The last follow-up showed that their preoperative Harris hip scores (42.3±3.2) were significantly improved (94.3±4.7) (t=2.873, P=0.002) and that 13 cases were rated as excellent and one as good. X-ray follow-up showed good position of their acetabular prostheses, no loosening of the cups or femoral prostheses, and no heterotopic ossification. Conclusion A 3D printed positioner for hip rotation center can effectively assist reconstruction of the hip rotation center and accurate implantation of acetabular prosthesis in total hip arthroplasty. Key words: Arthroplasty, replacement, hip; 3D printing techniques; Center of rotation; Positioner
用于全髋关节置换术的髋关节旋转中心3D打印定位器
目的评价三维打印髋关节旋转中心定位器在全髋关节置换术中的应用。方法2015年8月至2017年12月,郑州市骨科医院关节外科一科对14例股骨头缺血性坏死或股骨颈骨折患者进行单侧全髋关节置换术治疗。他们分别为8名男性和6名女性,平均年龄为51.8岁(37岁至65岁)。他们所有的手术都由髋关节旋转中心的3D打印定位器辅助。术后测量髋臼杯外展和前倾以及髋关节旋转中心,评估患侧髋关节旋转中枢(O2)与健康侧解剖旋转中枢(O1)之间的一致性,并在最后一次随访时记录患侧髋的功能和并发症。结果14例患者平均随访18个月(6~24个月)。术后O2和O1的纵坐标分别为19.36 mm±3.61 mm和18.33 mm±3.41 mm,横坐标分别为39.93 mm±2.97 mm和39.99 mm±3.16 mm,表明O2与O1一致(P>0.05)。最后一次随访显示,他们的术前Harris髋关节评分(42.3±3.2)显著改善(94.3±4.7)(t=2.873,P=0.002),其中13例被评为优秀,1例为良好。X线随访显示髋臼假体位置良好,髋臼杯或股骨假体无松动,无异位骨化。结论三维打印的髋关节旋转中心定位器能有效地辅助全髋关节置换术中髋关节旋转中枢的重建和髋臼假体的准确植入。关键词:关节成形术,置换术,髋关节;3D打印技术;旋转中心;定位器
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.70
自引率
0.00%
发文量
7288
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信