{"title":"How Many Microwave Disinfection Cycles is Safe for the Adaptability of Polymethyl Methacrylate (PMMA) Denture Base Materials?: An In Vitro Study","authors":"W. Ali, N. Ahmad, Sharifah Nor Ezura Syed Yussof","doi":"10.4103/denthyp.denthyp_97_21","DOIUrl":null,"url":null,"abstract":"Introduction: We aimed to determine the maximum microwave disinfection cycles that is safe for the adaptability of polymethyl methacrylate (PMMA) denture bases under power–time setting of 630 W for 3 minutes. Materials and Methods: Thirty PMMA maxillary denture bases were constructed and divided into two groups, control (no disinfection) and test (microwave disinfection at 630W for 3 minutes in water immersion). Coltene Rapid Liner (Coltene/Whaledent AG, Altstatten, Switzerland) silicone was coated onto the internal surface of the samples followed by placement of 8 kgf of axial load. The silicone film was removed, and weighed using analytical balance. One day interval was given between each cycle and samples were stored in 37°C water bath. Tests were carried out until a statistically significant silicone film weight change detected. The data were analyzed on SPSS version 21.0 (IBM Corp, Armonk, NY). Results: Statistically significant change of the denture base was detected after the tenth cycle of microwave irradiation. Conclusion: The maximum microwave disinfection cycles that is safe for the adaptability of PMMA denture bases under power–time setting of 630 W for 3 minutes is only up to 10 cycles.","PeriodicalId":43354,"journal":{"name":"Dental Hypotheses","volume":"13 1","pages":"99 - 102"},"PeriodicalIF":0.6000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Hypotheses","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/denthyp.denthyp_97_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1
Abstract
Introduction: We aimed to determine the maximum microwave disinfection cycles that is safe for the adaptability of polymethyl methacrylate (PMMA) denture bases under power–time setting of 630 W for 3 minutes. Materials and Methods: Thirty PMMA maxillary denture bases were constructed and divided into two groups, control (no disinfection) and test (microwave disinfection at 630W for 3 minutes in water immersion). Coltene Rapid Liner (Coltene/Whaledent AG, Altstatten, Switzerland) silicone was coated onto the internal surface of the samples followed by placement of 8 kgf of axial load. The silicone film was removed, and weighed using analytical balance. One day interval was given between each cycle and samples were stored in 37°C water bath. Tests were carried out until a statistically significant silicone film weight change detected. The data were analyzed on SPSS version 21.0 (IBM Corp, Armonk, NY). Results: Statistically significant change of the denture base was detected after the tenth cycle of microwave irradiation. Conclusion: The maximum microwave disinfection cycles that is safe for the adaptability of PMMA denture bases under power–time setting of 630 W for 3 minutes is only up to 10 cycles.