Risk factors and clinical manifestations of head-neck wear in artificial hip joints

Q4 Medicine
Bo Li, Xing-yu Zhao, Yuan-Xin Cheng, Yu Han, W. Feng, Dongsong Li
{"title":"Risk factors and clinical manifestations of head-neck wear in artificial hip joints","authors":"Bo Li, Xing-yu Zhao, Yuan-Xin Cheng, Yu Han, W. Feng, Dongsong Li","doi":"10.3760/CMA.J.ISSN.0253-2352.2020.03.007","DOIUrl":null,"url":null,"abstract":"At present, total hip arthroplasty (THA) is the primary treatment for hip diseases such as femoral head necrosis and developmental dysplasia of the hip. It has good effects in reducing pain and improving joint function. The appearance of modular hip prosthesis facilitates adjustment of limb length and femoral offset. However, the wear between the interface of hip prosthesis can lead to inflammatory pseudotumor, osteolysis and other adverse reactions. To explore the risk factors of wear between hip prosthesis interface is helpful to improve the design and manufacturing concept of the product, improve the product performance, help surgeons optimize the operation technology and reduce the impact of human factors on the wear of the prosthesis. Many literatures have reported the mechanism of wear between the head-acetabula interface of prosthesis. The mechanism of wear between the interfaces has been described relatively clearly. In addition to the head-acetabula interface, the wear between the head-neck interface is another major cause of unexplained pain around the joint and prosthesis loosening after hip replacement. Many factors affect head-neck wear. The design of prosthesis (such as prosthesis material and prosthesis taper), surgical technology (such as impact strength and prosthesis mismatch) and patient factors (such as age, gender and activity) have important impact on head-neck wear. Adverse reactions caused by head-neck wear have also been widely concerned. However, there is no considerable solution for wear prevention. Thus, we should optimize the design of prosthesis, improve the surgical technology, and guide the rehabilitation of patients to prevent wear. In order to improve the attention of joint surgeons, the present paper reviews the literatures and analyzes the risk factors of head-neck interface wear and the clinical manifestations caused by head-neck wear.","PeriodicalId":36405,"journal":{"name":"中华骨科杂志","volume":"40 1","pages":"178-185"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华骨科杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.0253-2352.2020.03.007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

At present, total hip arthroplasty (THA) is the primary treatment for hip diseases such as femoral head necrosis and developmental dysplasia of the hip. It has good effects in reducing pain and improving joint function. The appearance of modular hip prosthesis facilitates adjustment of limb length and femoral offset. However, the wear between the interface of hip prosthesis can lead to inflammatory pseudotumor, osteolysis and other adverse reactions. To explore the risk factors of wear between hip prosthesis interface is helpful to improve the design and manufacturing concept of the product, improve the product performance, help surgeons optimize the operation technology and reduce the impact of human factors on the wear of the prosthesis. Many literatures have reported the mechanism of wear between the head-acetabula interface of prosthesis. The mechanism of wear between the interfaces has been described relatively clearly. In addition to the head-acetabula interface, the wear between the head-neck interface is another major cause of unexplained pain around the joint and prosthesis loosening after hip replacement. Many factors affect head-neck wear. The design of prosthesis (such as prosthesis material and prosthesis taper), surgical technology (such as impact strength and prosthesis mismatch) and patient factors (such as age, gender and activity) have important impact on head-neck wear. Adverse reactions caused by head-neck wear have also been widely concerned. However, there is no considerable solution for wear prevention. Thus, we should optimize the design of prosthesis, improve the surgical technology, and guide the rehabilitation of patients to prevent wear. In order to improve the attention of joint surgeons, the present paper reviews the literatures and analyzes the risk factors of head-neck interface wear and the clinical manifestations caused by head-neck wear.
人工髋关节头颈磨损的危险因素及临床表现
目前,全髋关节置换术(THA)是治疗股骨头坏死和髋关节发育不良等髋关节疾病的主要方法。它在减轻疼痛和改善关节功能方面有很好的效果。模块化髋关节假体的出现便于调整肢体长度和股骨偏移。然而,髋关节假体界面之间的磨损会导致炎性假瘤、骨溶解等不良反应。探讨髋关节假体界面磨损的危险因素,有助于提高产品的设计和制造理念,提高产品性能,帮助外科医生优化手术技术,减少人为因素对假体磨损的影响。许多文献报道了假体头-髋臼界面磨损的机理。界面之间的磨损机制已经被相对清楚地描述。除了头-髋臼界面外,头-颈界面之间的磨损是髋关节置换术后关节周围不明原因疼痛和假体松动的另一个主要原因。许多因素会影响头颈磨损。假体的设计(如假体材料和假体锥度)、手术技术(如冲击强度和假体不匹配)和患者因素(如年龄、性别和活动)对头颈部磨损有重要影响。头颈部磨损引起的不良反应也受到广泛关注。然而,对于磨损预防,没有相当大的解决方案。因此,我们应该优化假体的设计,提高手术技术,指导患者的康复,防止磨损。为了提高关节外科医生的重视程度,本文对文献进行了综述,分析了头颈部界面磨损的危险因素以及头颈部磨损引起的临床表现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
中华骨科杂志
中华骨科杂志 Medicine-Surgery
CiteScore
0.80
自引率
0.00%
发文量
8153
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信