Layout and management of the surgical intensive care unit during the novel coronavirus infection epidemic period

Q3 Engineering
C. Shen, Bao-Ru Li, Xi Li, Sinan Liu, Xiaoxia Xin, Zengli Sun, Qingguang Liu, Chang Liu, Zheng Wu, Z. Wang
{"title":"Layout and management of the surgical intensive care unit during the novel coronavirus infection epidemic period","authors":"C. Shen, Bao-Ru Li, Xi Li, Sinan Liu, Xiaoxia Xin, Zengli Sun, Qingguang Liu, Chang Liu, Zheng Wu, Z. Wang","doi":"10.7652/JDYXB202005026","DOIUrl":null,"url":null,"abstract":"Objective: To discuss the key points of reconstruction from the surgical intensive care unit (SICU) to the negative pressure isolation ward which can treat patients with novel coronavirus pneumonia (NCP, COVID-19) Methods: The key points of the reconstruction are as follows: establishment of \"three zones and two passages\", transformation of the ventilation system, process management of personnel access room, and introduction of the visual management concept Results: The reconstructed SICU can maintain the original space area As for space layout, there are separate clean zone, semi-polluted zone and polluted zone as well as a separate passage for patients and medical personnel respectively, without the two groups of people contacting each other To achieve positive air pressure in the clean zone, negative air pressure in the semi-polluted zone is -5 Pa to -10 Pa, and negative air pressure in the patient zone is -10 Pa to -20 Pa And we ensure that the pressure difference (negative pressure) in adjacent rooms with the same pollution level is not less than 5 Pa Under normal circumstances, the pressure can be switched to positive one for admission of general ICU patients Results: Through the reconstruction, the SICU can meet the requirements of treatment of COVID-19 patients The main points of reconstruction are space layout and the air conditioning and ventilation system","PeriodicalId":35774,"journal":{"name":"Hsi-An Chiao Tung Ta Hsueh/Journal of Xi''an Jiaotong University","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hsi-An Chiao Tung Ta Hsueh/Journal of Xi''an Jiaotong University","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.7652/JDYXB202005026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To discuss the key points of reconstruction from the surgical intensive care unit (SICU) to the negative pressure isolation ward which can treat patients with novel coronavirus pneumonia (NCP, COVID-19) Methods: The key points of the reconstruction are as follows: establishment of "three zones and two passages", transformation of the ventilation system, process management of personnel access room, and introduction of the visual management concept Results: The reconstructed SICU can maintain the original space area As for space layout, there are separate clean zone, semi-polluted zone and polluted zone as well as a separate passage for patients and medical personnel respectively, without the two groups of people contacting each other To achieve positive air pressure in the clean zone, negative air pressure in the semi-polluted zone is -5 Pa to -10 Pa, and negative air pressure in the patient zone is -10 Pa to -20 Pa And we ensure that the pressure difference (negative pressure) in adjacent rooms with the same pollution level is not less than 5 Pa Under normal circumstances, the pressure can be switched to positive one for admission of general ICU patients Results: Through the reconstruction, the SICU can meet the requirements of treatment of COVID-19 patients The main points of reconstruction are space layout and the air conditioning and ventilation system
新型冠状病毒感染流行期外科重症监护病房的布置与管理
目的:探讨外科重症监护室(SICU)改造为新型冠状病毒肺炎(NCP,新冠肺炎)负压隔离病房的要点,人员出入室的流程管理,引入可视化管理理念结果:改造后的SICU可以保持原有的空间面积。在空间布局上,有单独的清洁区、半污染区和污染区,并分别为患者和医务人员提供单独的通道,为了在清洁区实现正气压,半污染区的负气压为-5Pa至-10Pa,患者区的负压为-10Pa至-20Pa。我们确保相同污染水平的相邻房间的压差(负压)不小于5Pa。在正常情况下,普通ICU患者可以将压力转换为正压。结果:通过重建,SICU可以满足新冠肺炎患者的治疗需求,改造的重点是空间布局和空调通风系统
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
25
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信