The relation between body weight and wear in total hip prosthesis: A finite element study

Shawn Ming Song Toh , Ariyan Ashkanfar , Russell English , Glynn Rothwell
{"title":"The relation between body weight and wear in total hip prosthesis: A finite element study","authors":"Shawn Ming Song Toh ,&nbsp;Ariyan Ashkanfar ,&nbsp;Russell English ,&nbsp;Glynn Rothwell","doi":"10.1016/j.cmpbup.2022.100060","DOIUrl":null,"url":null,"abstract":"<div><p>As the current obesity epidemic grows, an increased number of obese patients undergoing Total Hip Arthroplasty (THA) can be expected in the coming years. The National Health Service of the UK (NHS) recommends that an obese patient should undergo weight loss before THA. It is understood that an increased body weight would increase the wear rates on the prostheses, however, the extent of increased wear and the impact on the longevity of the prosthesis is unclear. The NHS found that 45% of THA failures in 2019 were caused by wear which led to a multitude of failures such as infection, aseptic loosening and dislocation such that a revision surgery is then needed. In this study, a finite element model was created to model a walking cycle and a newly developed wear algorithm was used to perform a series of computational wear analyses to investigate the effect of different patient weights on the evolution of wear in THAs up to 5 million cycles. The wear rates shown in this study are closely comparable to previous literature. The XLPE volumetric wear rates were found to be between 15 and 35 mm<sup>3</sup>/yr (range: 1.5–57 .6mm<sup>3</sup>/yr) and femoral head taper surface volumetric wear rates were between 0.174 and 0.225 mm<sup>3</sup>/yr (range: 0.01–3.15 mm<sup>3</sup>/yr). The results also showed that an increased weight of 140 kg can increase the metallic wear by 26% and polyethylene wear by 30% when compared to 100 kg body weight. As increased wear can lead to a multitude of failure such as aseptic loosening, dislocation and metallosis, from this study, it is recommended that obese patients undergo recommended weight loss and maintain this lesser weight to reduce wear and prolong the life of the THA.</p></div>","PeriodicalId":72670,"journal":{"name":"Computer methods and programs in biomedicine update","volume":"2 ","pages":"Article 100060"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666990022000118/pdfft?md5=f3068b40d16496b6265bbc65b00f9e7e&pid=1-s2.0-S2666990022000118-main.pdf","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer methods and programs in biomedicine update","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666990022000118","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

As the current obesity epidemic grows, an increased number of obese patients undergoing Total Hip Arthroplasty (THA) can be expected in the coming years. The National Health Service of the UK (NHS) recommends that an obese patient should undergo weight loss before THA. It is understood that an increased body weight would increase the wear rates on the prostheses, however, the extent of increased wear and the impact on the longevity of the prosthesis is unclear. The NHS found that 45% of THA failures in 2019 were caused by wear which led to a multitude of failures such as infection, aseptic loosening and dislocation such that a revision surgery is then needed. In this study, a finite element model was created to model a walking cycle and a newly developed wear algorithm was used to perform a series of computational wear analyses to investigate the effect of different patient weights on the evolution of wear in THAs up to 5 million cycles. The wear rates shown in this study are closely comparable to previous literature. The XLPE volumetric wear rates were found to be between 15 and 35 mm3/yr (range: 1.5–57 .6mm3/yr) and femoral head taper surface volumetric wear rates were between 0.174 and 0.225 mm3/yr (range: 0.01–3.15 mm3/yr). The results also showed that an increased weight of 140 kg can increase the metallic wear by 26% and polyethylene wear by 30% when compared to 100 kg body weight. As increased wear can lead to a multitude of failure such as aseptic loosening, dislocation and metallosis, from this study, it is recommended that obese patients undergo recommended weight loss and maintain this lesser weight to reduce wear and prolong the life of the THA.

全髋关节假体中体重与磨损关系的有限元研究
随着当前肥胖症的流行,预计在未来几年将有越来越多的肥胖患者接受全髋关节置换术(THA)。英国国民健康服务(NHS)建议肥胖患者在全髋关节置换术前进行减肥。据了解,体重增加会增加假体的磨损率,然而,增加的磨损程度和对假体寿命的影响尚不清楚。NHS发现,2019年45%的THA故障是由磨损引起的,这导致了感染、无菌性松动和脱位等多种故障,因此需要进行翻修手术。在本研究中,创建了一个有限元模型来模拟步行周期,并使用新开发的磨损算法进行一系列计算磨损分析,以研究不同患者体重对tha中长达500万次循环的磨损演变的影响。本研究显示的磨损率与以前的文献非常接近。XLPE的体积磨损率在15 - 35 mm3/年之间(范围:1.5 - 57.6 mm3/年),股骨头锥形表面的体积磨损率在0.174 - 0.225 mm3/年之间(范围:0.01-3.15 mm3/年)。结果还表明,与100 kg体重相比,重量增加140 kg可使金属磨损增加26%,聚乙烯磨损增加30%。由于磨损增加可导致多种故障,如无菌性松动、脱位和金属脱落,从本研究中,建议肥胖患者进行推荐的体重减轻并保持较轻的体重,以减少磨损并延长THA的寿命。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.90
自引率
0.00%
发文量
0
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信