Determination of Free Doxycycline Concentrations in the Plasma and Milk of Sheep and in the Plasma of Rabbits by using the HPLC Method

IF 0.4 Q4 VETERINARY SCIENCES
R. Mileva
{"title":"Determination of Free Doxycycline Concentrations in the Plasma and Milk of Sheep and in the Plasma of Rabbits by using the HPLC Method","authors":"R. Mileva","doi":"10.2478/macvetrev-2019-0016","DOIUrl":null,"url":null,"abstract":"Abstract A fast and sensitive HPLC method was validated in order to analyze doxycycline in plasma and milk of sheep and in plasma of rabbits. The samples were processed with trifluoroacetic acid (TFA). After the centrifugation step, a supernatant containing extracted doxycycline and internal standard oxytetracycline was injected into the HPLC system with PDA detection. The method showed linearity in the range of 0.125 - 2.5 µg/mL for ovine plasma, 0.125 – 5.0 µg/mL for ovine milk, and 0.125 – 1 µg/mL for rabbit plasma. The inter-assay precision varied between 5.69 – 13.55 %. Values for intra-assay precision were between 0.62 – 8.67 %. Accuracy was higher than 90% in all of the tested concentrations in the three types of biological matrices. The mean extraction recovery was higher than 90 % for all matrices. In order to handle only with free drug concentrations, microfiltration of standard solutions with low (0.25mg/mL), medium (0.5mg/mL) and high (1.0mg/mL) concentration was performed. A percentage for correction of the quantified doxycycline was calculated. The most significant adjustments should be made at the low concentrations. The correction for rabbit plasma is 24.63±5.03%, for ovine plasma is 20.10±8.01% and for milk–16.68±0.04 %. This method can be used for routine determination of doxycycline concentrations for pharmacokinetic studies and further dosage adjustment.","PeriodicalId":18099,"journal":{"name":"Macedonian Veterinary Review","volume":"42 1","pages":"123 - 130"},"PeriodicalIF":0.4000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Macedonian Veterinary Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/macvetrev-2019-0016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 10

Abstract

Abstract A fast and sensitive HPLC method was validated in order to analyze doxycycline in plasma and milk of sheep and in plasma of rabbits. The samples were processed with trifluoroacetic acid (TFA). After the centrifugation step, a supernatant containing extracted doxycycline and internal standard oxytetracycline was injected into the HPLC system with PDA detection. The method showed linearity in the range of 0.125 - 2.5 µg/mL for ovine plasma, 0.125 – 5.0 µg/mL for ovine milk, and 0.125 – 1 µg/mL for rabbit plasma. The inter-assay precision varied between 5.69 – 13.55 %. Values for intra-assay precision were between 0.62 – 8.67 %. Accuracy was higher than 90% in all of the tested concentrations in the three types of biological matrices. The mean extraction recovery was higher than 90 % for all matrices. In order to handle only with free drug concentrations, microfiltration of standard solutions with low (0.25mg/mL), medium (0.5mg/mL) and high (1.0mg/mL) concentration was performed. A percentage for correction of the quantified doxycycline was calculated. The most significant adjustments should be made at the low concentrations. The correction for rabbit plasma is 24.63±5.03%, for ovine plasma is 20.10±8.01% and for milk–16.68±0.04 %. This method can be used for routine determination of doxycycline concentrations for pharmacokinetic studies and further dosage adjustment.
高效液相色谱法测定绵羊血浆、乳汁和家兔血浆中游离多西环素浓度
摘要建立了快速、灵敏的高效液相色谱法分析绵羊血浆、羊奶和家兔血浆中强力霉素的方法。样品用三氟乙酸(TFA)处理。离心后,将含有强力霉素和内标土霉素的上清液注入高效液相色谱系统,采用PDA检测。该方法在0.125 ~ 2.5µg/mL羊血浆、0.125 ~ 5.0µg/mL羊奶和0.125 ~ 1µg/mL兔血浆的线性范围内良好。精密度在5.69 ~ 13.55%之间。测定内精密度在0.62 ~ 8.67%之间。在三种类型的生物基质中,所有测试浓度的准确性均高于90%。所有基质的平均萃取回收率均大于90%。为了只处理游离药物浓度,对低浓度(0.25mg/mL)、中浓度(0.5mg/mL)和高浓度(1.0mg/mL)的标准溶液进行微滤。计算定量多西环素的校正百分率。最重要的调整应在低浓度时进行。兔血浆校正率为24.63±5.03%,羊血浆校正率为20.10±8.01%,牛奶校正率为16.68±0.04%。该方法可用于多西环素药代动力学研究和剂量调整的常规测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Macedonian Veterinary Review
Macedonian Veterinary Review Veterinary-Veterinary (all)
CiteScore
1.00
自引率
0.00%
发文量
20
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信