{"title":"Advanced oxidation of high concentrations of formaldehyde in aqueous solution under fluorescent and UV light","authors":"F. Deniz, M. A. Mazmancı","doi":"10.34172/ehem.2021.30","DOIUrl":null,"url":null,"abstract":"Background: Formaldehyde (FA) is a carcinogen compound, which is soluble in water. FA can be removed from aqueous solution using advanced oxidation methods. Methods: In this study, the oxidation of FA was studied under fluorescent and UV light. Hydrogen peroxide (H2 O2 ) was used as an oxidant. The pH value and H2 O2 amount of samples were optimized. The chemical oxygen demand (COD), FA concentration, and H2 O2 consumption were followed. Results: It was observed that the pH value of the sample was more significant under fluorescent light than UV light at oxidation of FA. The highest COD removal and H2 O2 reduction were 18.57 and 30.90%, respectively, at pH 12.00, with a 1:1 ratio of FA:H2 O2 under fluorescent light. 86.41% FA and 62.12% COD removal were achieved at pH 7.00, with a 1:2 ratio of FA:H2 O2 , under UV light. It was observed that H2 O2 was consumed at all pH values under UV light. On the other hand, under fluorescent light, the concentration of H2 O2 decreased only at pH 12. In control samples containing only H2 O2 , the H2 O2 reduction was 92.09% at pH 11.91, while it was 2-6% at other pH levels under fluorescent light. The H2 O2 reduction changed between 33 and 44% at different pH values under UV light. The oxidation of FA was found to be suitable for the pseudo-first-order kinetic model and Langmuir isotherm model. Conclusion: The most effective oxidation was obtained at the original pH value (7.00) and 1:2 ratio of FA:H2 O2 under UV light.","PeriodicalId":51877,"journal":{"name":"Environmental Health Engineering and Management Journal","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2021-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Health Engineering and Management Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/ehem.2021.30","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 2
Abstract
Background: Formaldehyde (FA) is a carcinogen compound, which is soluble in water. FA can be removed from aqueous solution using advanced oxidation methods. Methods: In this study, the oxidation of FA was studied under fluorescent and UV light. Hydrogen peroxide (H2 O2 ) was used as an oxidant. The pH value and H2 O2 amount of samples were optimized. The chemical oxygen demand (COD), FA concentration, and H2 O2 consumption were followed. Results: It was observed that the pH value of the sample was more significant under fluorescent light than UV light at oxidation of FA. The highest COD removal and H2 O2 reduction were 18.57 and 30.90%, respectively, at pH 12.00, with a 1:1 ratio of FA:H2 O2 under fluorescent light. 86.41% FA and 62.12% COD removal were achieved at pH 7.00, with a 1:2 ratio of FA:H2 O2 , under UV light. It was observed that H2 O2 was consumed at all pH values under UV light. On the other hand, under fluorescent light, the concentration of H2 O2 decreased only at pH 12. In control samples containing only H2 O2 , the H2 O2 reduction was 92.09% at pH 11.91, while it was 2-6% at other pH levels under fluorescent light. The H2 O2 reduction changed between 33 and 44% at different pH values under UV light. The oxidation of FA was found to be suitable for the pseudo-first-order kinetic model and Langmuir isotherm model. Conclusion: The most effective oxidation was obtained at the original pH value (7.00) and 1:2 ratio of FA:H2 O2 under UV light.