Wearable Devices in Pulmonary Arterial Hypertension: What Are We Trying to Learn?

D. Lachant, R. White
{"title":"Wearable Devices in Pulmonary Arterial Hypertension: What Are We Trying to Learn?","authors":"D. Lachant, R. White","doi":"10.21693/1933-088x-22.2.92","DOIUrl":null,"url":null,"abstract":"\n \n Wearable technologies (accelerometers) are currently being evaluated as an alternative to the 6-minute walk test as an objective measure of functional status in pulmonary arterial hypertension (PAH). Multiple observational studies incorporating accelerometers have shown patients with PAH have low physical activity (PA) time.\n \n \n \n Despite widespread use of accelerometers, PA has not been shown to increase after adding vasodilator therapy, which suggests a behavioral component influencing activity. A decrease in PA from baseline may identify clinical worsening and someone at risk for future hospitalization. Cardiac Effort, the number of heart beats used during the 6-minute walk test/6-minute walk distance (beats per meter), has less variability than 6-minute walk distance and provides a comparable clinic measurement in the home setting. Cardiac Effort may provide a better remote measurement than changes in total daily activity when evaluating for clinical improvement.\n \n \n \n The amount and duration of PA achieved in patients with PAH is likely related to a combination of right ventricular (RV) function, deconditioning, and environmental factors. Strategies to target all aspects are needed to improve PA. Further studies are needed to determine the optimal remote measure and monitoring period.\n","PeriodicalId":92747,"journal":{"name":"Advances in pulmonary hypertension","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in pulmonary hypertension","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21693/1933-088x-22.2.92","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Wearable technologies (accelerometers) are currently being evaluated as an alternative to the 6-minute walk test as an objective measure of functional status in pulmonary arterial hypertension (PAH). Multiple observational studies incorporating accelerometers have shown patients with PAH have low physical activity (PA) time. Despite widespread use of accelerometers, PA has not been shown to increase after adding vasodilator therapy, which suggests a behavioral component influencing activity. A decrease in PA from baseline may identify clinical worsening and someone at risk for future hospitalization. Cardiac Effort, the number of heart beats used during the 6-minute walk test/6-minute walk distance (beats per meter), has less variability than 6-minute walk distance and provides a comparable clinic measurement in the home setting. Cardiac Effort may provide a better remote measurement than changes in total daily activity when evaluating for clinical improvement. The amount and duration of PA achieved in patients with PAH is likely related to a combination of right ventricular (RV) function, deconditioning, and environmental factors. Strategies to target all aspects are needed to improve PA. Further studies are needed to determine the optimal remote measure and monitoring period.
可穿戴设备在肺动脉高压中的应用:我们正在尝试学习什么?
可穿戴技术(加速度计)目前正在评估作为6分钟步行测试的替代方案,作为肺动脉高压(PAH)功能状态的客观测量。使用加速度计的多项观察性研究表明,PAH患者的身体活动时间较低。尽管加速度计被广泛使用,但PA并未在加入血管扩张剂治疗后增加,这表明行为成分影响活动。PA从基线开始下降可能表明临床恶化,并且可能存在未来住院的风险。心脏努力,即6分钟步行测试中使用的心跳次数/6分钟步行距离(每米节拍),与6分钟步行距离相比具有更小的可变性,并在家庭环境中提供了可比的临床测量。在评估临床改善时,心功可能比每日总活动量的变化提供更好的远程测量。PAH患者获得的PA量和持续时间可能与右心室(RV)功能、去调节和环境因素的组合有关。需要针对各个方面的策略来改善PA。需要进一步研究确定最佳的远程测量和监测周期。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信