{"title":"Recommendations for Improvement of the Thermal Performance of an Office Building Based on Retrofitting the Glazed Curtain Wall","authors":"Neşe Di̇kmen, Canan Altundaş","doi":"10.35378/gujs.997496","DOIUrl":null,"url":null,"abstract":"Glazed curtain wall systems have become indispensable particularly in office buildings due to their light weight, aesthetic appearance, easy installation and resistance to climate conditions. Curtain walls however, also have problems in terms of thermal efficiency because of their wide, glazing windows and metal frames that have high thermal conductivity. The aim of this study is to offer proposals for improving the thermal performance of an office building with a glass curtain wall system built in a hot-humid climate zone. An office building constructed in Antalya, Turkey was modelled with the help of DesignBuilder energy simulation software and various modifications were made on the model in order to improve the thermal performance of the building. With the improvements proposed in the study, it is possible to decrease the annual thermal loads of the whole building by 6.6%, and the annual thermal loads of the space with the curtain wall by 33.2%. The study revealed that, applying an additional envelope is more effective than lowering the U-value of the glass of the curtain wall in terms of thermal performance improvement.","PeriodicalId":12615,"journal":{"name":"gazi university journal of science","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2022-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"gazi university journal of science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35378/gujs.997496","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Glazed curtain wall systems have become indispensable particularly in office buildings due to their light weight, aesthetic appearance, easy installation and resistance to climate conditions. Curtain walls however, also have problems in terms of thermal efficiency because of their wide, glazing windows and metal frames that have high thermal conductivity. The aim of this study is to offer proposals for improving the thermal performance of an office building with a glass curtain wall system built in a hot-humid climate zone. An office building constructed in Antalya, Turkey was modelled with the help of DesignBuilder energy simulation software and various modifications were made on the model in order to improve the thermal performance of the building. With the improvements proposed in the study, it is possible to decrease the annual thermal loads of the whole building by 6.6%, and the annual thermal loads of the space with the curtain wall by 33.2%. The study revealed that, applying an additional envelope is more effective than lowering the U-value of the glass of the curtain wall in terms of thermal performance improvement.
期刊介绍:
The scope of the “Gazi University Journal of Science” comprises such as original research on all aspects of basic science, engineering and technology. Original research results, scientific reviews and short communication notes in various fields of science and technology are considered for publication. The publication language of the journal is English. Manuscripts previously published in another journal are not accepted. Manuscripts with a suitable balance of practice and theory are preferred. A review article is expected to give in-depth information and satisfying evaluation of a specific scientific or technologic subject, supported with an extensive list of sources. Short communication notes prepared by researchers who would like to share the first outcomes of their on-going, original research work are welcome.